Analysis of thermally-induced effects in Planck Low Frequency Instrument
read the original abstract
The Planck mission will provide full-sky maps of the Cosmic Microwave Background with unprecedented angular resolution (~ 10') and sensitivity (DT / T = 10^-6). This requires cryogenically cooled, high sensitivity detectors as well as an extremely accurate control of systematic errors, which must be kept at micro-K level. In this work we focus on systematic effects arising from thermal instabilities in the Low Frequency Instrument operating in the 30-100 GHz range. Our results show that it is of crucial importance to assure "in hardware" a high degree of stability. In addition, we provide an estimate of the level at which it is possible to reduce the contamination level in the observed maps by proper analysis of the Time Ordered Data.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
CMB power spectra and cosmological parameters from Planck PR4 with CamSpec
Planck PR4 NPIPE maps processed with CamSpec produce LCDM parameters consistent with 2018 results but with ~10% tighter constraints and shifts toward LCDM values for extensions like Omega_K and A_Lens.
discussion (0)