Four-gap glass RPC as a candidate to a large area thin time-of-flight detector
classification
✦ hep-ex
keywords
detectorresolutionareadonefour-gapglasshavinglarge
read the original abstract
A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution dependently on a pad size are presented. This paper contains first result on the timing RPC (with ~ 100ps resolution) having a strip read-out. Study has been done within the HARP experiment (CERN-PS214) R&D work. A obtaned data can be useful if a design of a large area thin timing detector has to be done.