pith. sign in

arxiv: hep-ex/0507053 · v1 · submitted 2005-07-12 · ✦ hep-ex

Selectron Mass Reconstruction and the Resolution of the Linear Collider Detector

classification ✦ hep-ex
keywords massselectrondetectorreconstructionregionresolutionbeamdesign
0
0 comments X
read the original abstract

We have used ISAJET and the JAS LCD fast simulation to explore the precision of Snowmass Point SPS1a selectron mass reconstruction for the Silicon Detector concept. Simulating collisions at E_cm = 1 TeV, we have found that most of the information constraining the selectron mass is carried in the forward (|cos(theta)| > 0.8) region. We have also found that, for a beam energy spread of 1% (conventional RF design), detector resolution limitations compromise the selectron mass reconstruction only in the forward region. However, for a beam energy spread of less than 0.2% (superconducting RF design), the detector resolution compromises the selectron mass reconstruction over the full angular region.