pith. sign in

arxiv: 0906.1961 · v2 · submitted 2009-06-10 · ⚛️ physics.optics

Measuring the true quality factor of an ultrafast photonic microcavity: homogeneous versus inhomogeneous broadening

classification ⚛️ physics.optics
keywords cavityfactorqualitytimebroadeninggaasinhomogeneousinverse
0
0 comments X
read the original abstract

We have measured time-resolved the photon storage time and the quality factor of an ultrafast photonic cavity using an autocorrelator. The cavity consists of a $\lambda$-thick GaAs layer sandwiched between GaAs/AlAs distributed Bragg reflectors and resonates at 985 nm wavelength. The inverse relative linewidth measured with white light reflectivity is 830, while the quality factor obtained from the time resolved measurements is 1500. The photon storage time in the cavity is 0.78 ps. We show that the difference between the quality factor and the inverse relative linewidth results from inhomogeneous broadening of the microcavity resonance due to a spatial gradient in the cavity layer.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.