Design and operation of LongBo: a 2 m long drift liquid argon TPC

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1504.00398 v2 pith:7OOCHL75 submitted 2015-04-01 physics.ins-det

classification physics.ins-det
keywords channelsargondriftliquiddiscretelongbopreamplifiersasic
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

In this paper, we report on the design and operation of the LongBo time projection chamber in the Liquid Argon Purity Demonstrator cryostat. This chamber features a 2 m long drift distance. We measure the electron drift lifetime in the liquid argon using cosmic ray muons and the lifetime is at least 14 ms at 95\% confidence level. LongBo is equipped with preamplifiers mounted on the detector in the liquid argon. Of the 144 channels, 128 channels were readout by preamplifiers made with discrete circuitry and 16 channels were readout by ASIC preamplifiers. For the discrete channels, we measure a signal-to-noise (S/N) ratio of 30 at a drift field of 350 V/cm. The measured S/N ratio for the ASIC channels was 1.4 times larger than that measured for the discrete channels.