REVIEW 1 cited by
Electron attenuation measurement using cosmic ray muons at the MicroBooNE LArTPC
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Signed reviews
read the original abstract
The MicroBooNE experiment at Fermilab uses liquid argon time projection chamber (LArTPC) technology to study neutrino interactions in argon. A fundamental requirement for LArTPCs is to achieve and maintain a low level of electronegative contaminants in the liquid to minimize the capture of drifting ionization electrons. The attenuation time for the drifting electrons should be long compared to the maximum drift time, so that the signals from particle tracks that generate ionization electrons with long drift paths can be detected efficiently. In this talk we present MicroBooNE measurement of electron attenuation using cosmic ray muons. The result yields a minimum electron 1/e lifetime of 18 ms under typical operating conditions, which is long compared to the maximum drift time of 2.3 ms.
Forward citations
Cited by 1 Pith paper
-
Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout
Simulations show a Q-Pix liquid argon detector could, in a low-background underground scenario, see boron-8 and hep solar neutrinos above about 5 MeV if poorly understood gamma and alpha-capture backgrounds are controlled.
Discussion (0). Continue with ORCID to comment.