Pith. sign in

REVIEW

Learn to segment single cells with deep distance estimator and deep cell detector

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1803.10829 v2 pith:CAJYP75N submitted 2018-03-28 q-bio.QM

classification q-bio.QM
keywords cellsegmentationcellsmethodaccuracyclassificationimagespixel-wise
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Single cell segmentation is critical and challenging in live cell imaging data analysis. Traditional image processing methods and tools require time-consuming and labor-intensive efforts of manually fine-tuning parameters. Slight variations of image setting may lead to poor segmentation results. Recent development of deep convolutional neural networks(CNN) provides a potentially efficient, general and robust method for segmentation. Most existing CNN-based methods treat segmentation as a pixel-wise classification problem. However, three unique problems of cell images adversely affect segmentation accuracy: lack of established training dataset, few pixels on cell boundaries, and ubiquitous blurry features. The problem becomes especially severe with densely packed cells, where a pixel-wise classification method tends to identify two neighboring cells with blurry shared boundary as one cell, leading to poor cell count accuracy and affecting subsequent analysis. Here we developed a different learning strategy that combines strengths of CNN and watershed algorithm. The method first trains a CNN to learn Euclidean distance transform of binary masks corresponding to the input images. Then another CNN is trained to detect individual cells in the Euclidean distance transform. In the third step, the watershed algorithm takes the outputs from the previous steps as inputs and performs the segmentation. We tested the combined method and various forms of the pixel-wise classification algorithm on segmenting fluorescence and transmitted light images. The new method achieves similar pixel accuracy but significant higher cell count accuracy than pixel-wise classification methods do, and the advantage is most obvious when applying on noisy images of densely packed cells.

Discussion (0). Continue with ORCID to comment.

Pith tools