Pith. sign in

REVIEW

Production and characterization of a PbMoO$_4$ cryogenic detector from archaeological Pb

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1906.09296 v2 pith:GHFB4LRD submitted 2019-06-21 physics.ins-det physics.app-ph

classification physics.ins-detphysics.app-ph
keywords detectorarchaeologicalcryogenicpbmoocharacteristicscompoundcrystalexcellent
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We operated a PbMoO$_4$ scintillating cryogenic detector of 570 g, produced with archaeological lead. This compound features excellent low temperature characteristics in terms of light yield, 12 keV/MeV for $\beta/\gamma$ interactions, and FWHM energy resolution, 11.7 keV at 2.6 MeV. Furthermore, the detector allows for an effective particle identification by means of pulse shape analysis on the heat read-out channel. The implementation of innovative techniques and procedures for the purification of raw materials used for the crystal growth, and the highly-pure archaeological Pb, allowed the production of large volume high quality crystal. The overall characteristics of the detector operated at cryogenic temperatures makes PbMoO$_4$ an excellent compound for neutrino physics applications, especially neutrinoless double-beta studies.