REVIEW 1 cited by
The Cryogenics and Xenon handling system for the PandaX-4T Experiment
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large detector. In this paper, the results on the commission of the cryogenics and gas handling system are reported. The maximum cooling power of ~ 580 W at 178 K with three cooperating coldheads has been achieved. The filling rate with an assisted liquid nitrogen cooling can reach ~ 700 kg/day. The average rate of recuperation by liquid nitrogen is around 440 kg/day. The maximum total purification speed of two circulation loops is up to ~ 155 slpm. Each loop is using a large heat exchanger with a measured heat exchange efficiency of ~ 97.5+-0.5%.
Forward citations
Cited by 1 Pith paper
-
Measurement of two-neutrino double electron capture half-life of $^{124}$Xe with PandaX-4T
PandaX-4T measured the 124Xe two-neutrino double electron capture half-life as (1.03±0.15_stat±0.08_sys)×10^22 years and a K-shell capture fraction of (65±5)% from 1.73 tonne-years of exposure.
Discussion (0). Continue with ORCID to comment.