REVIEW 2 cited by
Readout electronics and data acquisition system of PandaX-4T experiment
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500 photomultipliers instrumented in the top and the bottom of the detector. In this paper we present a completely new system of readout electronics and data acquisition in the PandaX-4T experiment. Compared to the one used in the previous PandaX dark matter experiments, the new system features triggerless readout and higher bandwidth. With triggerless readout, dark matter searches are not affected by the efficiency loss of external triggers. The system records single photelectron signals of the dominant PMTs with an average efficiency of 96\%, and achieves the bandwidth of more than 450 MB/s. The system has been used to successfully acquire data during the commissioning runs of PandaX-4T.
Forward citations
Cited by 2 Pith papers
-
AURORA: A High Performance Software DAQ Framework for Next-Generation Rare-Event Search Experiments
AURORA delivers a scalable DAQ system projected to exceed 3 GB/s throughput for experiments like PandaX-xT that generate up to 1.6 GB/s from 3000+ channels at 500 MSa/s.
-
Characterization of Hamamatsu R11410-23 Photomultiplier Tubes and Performance in the PandaX-4T Detector
The PandaX-4T collaboration reports the first full characterization of 422 R11410-23 PMTs and documents their stable in-situ performance during the commissioning run.
Discussion (0). Continue with ORCID to comment.