Pith. sign in

REVIEW 2 cited by

Searching for Low-Mass Axions using Resonant Upconversion

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2301.06778 v2 pith:7Y3SAIZX submitted 2023-01-17 hep-ex

classification hep-ex
keywords axionsaxiondetectionexperimentfrequencyresonantupconversionbackground
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We present new results of a room temperature resonant AC haloscope, which searches for axions via photon upconversion. Traditional haloscopes require a strong applied DC magnetic background field surrounding the haloscope cavity resonator, the resonant frequency of which is limited by available bore dimensions. UPLOAD, the UPconversion Low-Noise Oscillator Axion Detection experiment, replaces this DC magnet with a second microwave background resonance within the detector cavity, which upconverts energy from the axion field into the readout mode, accessing axions around the beat frequency of the modes. Furthermore, unlike the DC case, the experiment is sensitive to a newly proposed quantum electromagnetodynamical axion coupling term $g_{aBB}$. Two experimental approaches are outlined - one using frequency metrology, and the other using power detection of a thermal readout mode. The results of the power detection experiment are presented, which allows exclusion of axions of masses between 1.12 $-$ 1.20 $\mu eV$ above a coupling strength of both $g_{a\gamma\gamma}$ and $g_{aBB}$ at $3 \times 10^{-6}$ 1/GeV, after a measurement period of 30 days, which is a three order of magnitude improvement over our previous result.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Axiverse Lampposts

    hep-ph 2026-02 conditional novelty 6.0 of 10

    In a hierarchical multi-axion theory with random couplings, axion field ranges shrink with 1/sqrt(N), generic axion–SM couplings are suppressed, but the QCD axion's coupling is unsuppressed.

  2. Cavity Multimodes as an Array for High-Frequency Gravitational Waves

    hep-ph 2026-01 conditional novelty 6.0 of 10

    A 9-cell microwave cavity's 18 modes can act as a synthetic detector array that reconstructs the direction, polarization, and chirp of a high-frequency gravitational-wave signal.

Pith tools