Pith. sign in

REVIEW

Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2306.00818 v2 pith:3E4TT5PE submitted 2023-06-01 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords detectoroperationradiationsipmcircdamagehighpower
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.

Discussion (0). Continue with ORCID to comment.

Pith tools