Pith. sign in

REVIEW

An anthropomorphic thyroid phantom for ultrasound-guided radiofrequency ablation of nodules

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2307.11652 v1 pith:7MNNN2TG submitted 2023-07-21 physics.med-ph

classification physics.med-ph
keywords ablationthermalphantomthyroidultrasound-guidedwereanthropomorphicmedian
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Background: Needle-based procedures such as fine needle aspiration (FNA) and thermal ablation, are often applied for thyroid nodule diagnosis and therapeutic purposes, respectively. With blood vessels and nerves nearby, these procedures can pose risks in damaging surrounding critical structures. Purpose: The development and validation of innovative strategies to manage these risks require a test object with well-characterized physical properties. For this work, we focus on the application of ultrasound-guided thermal radio-frequency ablation (RFA). Methods: We have developed an anthropomorphic phantom mimicking the thyroid and surrounding anatomical and physiological structures that are relevant to ultrasound-guided thermal ablation. The phantom was composed of a mixture of polyacrylamide, water, and egg white extract and was cast using molds in multiple steps. The thermal, acoustical, and electrical characteristics were experimentally validated. The ablation zones were analyzed via non-destructive T2-weighted MRI scans utilizing the relaxometry changes of coagulated egg albumen, and the temperature distribution was monitored using an array of fiber Bragg sensors. Results: The physical properties of the phantom were verified both on ultrasound as well as its response to thermal ablation. The final temperature achieved (92{\deg}C), the median percentage of the nodule ablated (82.1%), the median volume ablated outside the nodule (0.8 mL), and the median number of critical structures affected (0) were quantified. Conclusion: An anthropomorphic phantom that can provide a realistic model for development and training in ultrasound-guided needle-based thermal interventions for thyroid nodules has been presented. In the future, this model can also be extended to novel needle-based diagnostic procedures.

Discussion (0). Continue with ORCID to comment.

Pith tools