Pith. sign in

REVIEW 1 cited by

Dynamic Ancillary Services: From Grid Codes to Transfer Function-Based Converter Control

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2310.01552 v5 pith:W7MB4PKX submitted 2023-10-02 eess.SY cs.SY

classification eess.SYcs.SY
keywords curvesdynamicancillarycontrolconverterfrequencygrid-codelinear
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Conventional grid-code specifications for dynamic ancillary services provision such as fast frequency and voltage regulation are typically defined by means of piece-wise linear step-response capability curves in the time domain. However, although the specification of such time-domain curves is straightforward, their practical implementation in a converter-based generation system is not immediate, and no customary methods have been developed yet. In this paper, we thus propose a systematic approach for the practical implementation of piece-wise linear time-domain curves to provide dynamic ancillary services by converter-based generation systems, while ensuring grid-code and device-level requirements to be reliably satisfied. Namely, we translate the piece-wise linear time-domain curves for active and reactive power provision in response to a frequency and voltage step change into a desired rational parametric transfer function in the frequency domain, which defines a dynamic response behavior to be realized by the converter. The obtained transfer function can be easily implemented e.g. via a PI-based matching control in the power loop of standard converter control architectures. We demonstrate the performance of our method in numerical grid-code compliance tests, and reveal its superiority over classical droop and virtual inertia schemes which may not satisfy the grid codes due to their structural limitations.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Small-signal stability of power systems with voltage droop

    math.OC 2024-11 conditional novelty 7.0 of 10

    Local, transfer-function-based sufficient conditions certify small-signal stability of lossless or constant-R/X grids with V-q droop grid-forming inverters.

Pith tools