Pith. sign in

REVIEW 1 cited by

De-aberration for transcranial photoacoustic computed tomography through an adult human skull

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.05937 v2 pith:3LWV5IRW submitted 2024-04-09 physics.med-ph

classification physics.med-ph
keywords skullhumanpacttranscranialde-aberrationex-vivoimagesadult
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential as a complementary technology to functional MRI, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images -- a problem that has remained unsolved for the past two decades. Herein, we report the first successful experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, we faithfully de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull for different levels of phantom complexity and positions. We also demonstrate the generality of our results by attaining a similar extent of de-aberration through a second ex-vivo human skull. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Helmet ultrasound for brain imaging in post-hemicraniectomy patients

    physics.med-ph 2025-05 conditional novelty 6.0 of 10

    A helmet-mounted scanned ultrasound array images brain structure and blood flow in post-hemicraniectomy patients with submillimeter resolution, including motion-corrected repeated sessions.

Pith tools