Pith. sign in

REVIEW

Improving nuclear magnetic resonance and electron spin resonance thermometry with size reduction of superparamagnetic iron oxide nanoparticles

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.13180 v1 pith:4TSX2AY3 submitted 2024-04-19 physics.app-ph

classification physics.app-ph
keywords temperatureresonancethermometrymagneticspionsdependentlinewidthself-diffusion
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Thermometry based on magnetic resonance has been extensively studied due to its important application in biomedical imaging. In our previous work, we showed that the spin-spin relaxation time (T2) of nuclear magnetic resonance (NMR) in water is a highly sensitive thermometer as T2 scales with the highly temperature-sensitive self-diffusion constant of water. In this work, in addition to temperature dependent self-diffusion constant of a fluid, we utilize the temperature dependent magnetization of 4 nm SPIONs to improve T2 sensitivity (4.96) by 1.4 times over self-diffusion (3.48) alone in hexane between 248 K and 333 K. To extend the application of NMR T2 thermometry to engineering systems, we also investigate the temperature dependence of T2 in mineral oil (Thermo Scientific, J62592), which exhibits remarkably high sensitivity (11.62) between 273 K and 353 K. This result implies that applications of NMR T2 thermometry in heat transfer fluids are promising. NMR thermometry, however, is generally not applicable to solids. Therefore, we also evaluate the potential of electron spin resonance (ESR) thermometry with SPIONs in solids between 100 K and 290 K, for potential temperature monitoring in biomedical and engineering applications. The size and concentration effects on ESR signals are studied systematically, and our results show that the temperature dependent linewidth follows a T^-2 law for 4 nm SPIONs, while the concentration of SPIONs has no impact on the temperature dependence of the ESR linewidth. The linewidth at room temperature at 9.4 GHz is 10.5 mT. Combining our NMR and ESR results, we find that to obtain higher temperature sensitivity in a magnetic resonance technique using SPIONs, SPION with a small magnetic moment, i.e., a small volume and reduced magnetization, are beneficial.

Discussion (0). Continue with ORCID to comment.

Pith tools