Pith. sign in

REVIEW 2 cited by

A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2405.18980 v2 pith:GRXMFZTY submitted 2024-05-29 physics.ins-det

classification physics.ins-det
keywords crystaldesignstructurearraycrossdesignsdetectorsgamma
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initial $Thick$ version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ~6% in a finer ($Slim$) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in $^{100}$Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5--7 keV FWHM at 2615 keV $\gamma$s, nearby the Q-value of $^{100}$Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ~0.3 keV (150 photons) for 1-MeV $\gamma$($\beta$) LMO-event. Despite that, an acceptable separation between $\alpha$ and $\gamma$($\beta$) events is achieved with most devices. The highest efficiency is reached with light detectors in the $Thick$ design thanks to a lower baseline noise width (0.05--0.09 keV RMS) when compared to that obtained in the $Slim$ version (0.10--0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.

Discussion (0). Sign in to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Vibrational sensing at mK temperatures in dry dilution refrigerators using commercial accelerometers for diverse fundamental physics applications

    physics.ins-det 2026-01 conditional novelty 5.0 of 10

    Commercial Endevco 2271A accelerometers operated at 8 mK on a dilution-refrigerator mixing-chamber plate and resolved pulse-tube harmonics, with a radioassay bounding their 40K/232Th contamination.

  2. Muon veto system for the CROSS double-beta decay search experiment

    physics.ins-det 2025-10 conditional novelty 4.0 of 10

    A nine-sector muon veto with single-sector trigger logic is projected to reject 99.7% of muon-induced events in the CROSS 0νββ region of interest, reducing that background to ~2e-3 cnts/keV/kg/yr.

Pith tools