Pith. sign in

REVIEW 1 cited by

Effects of Mosaic Crystal Instrument Functions on X-ray Thomson Scattering Diagnostics

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2406.03301 v2 pith:USYHHITJ submitted 2024-06-05 physics.plasm-ph physics.ins-det

classification physics.plasm-phphysics.ins-det
keywords xrtsmosaictemperatureasymmetryconsiderconsiderationcrystalsdetailed
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Mosaic crystals, with their high integrated reflectivities, are widely-employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 $\mu$m and 100 $\mu$m mosaic HAPG crystals, and how the broadening varies across the spectrometer in an energy range of 6.7-8.6 keV. Notably, we find a strong asymmetry in the shape of the IF towards higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas, and find that the temperature can be overestimated if an approximate symmetric IF is used. We therefore expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modelling and model-free approaches.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Methods for energy dispersive x-ray spectroscopy with photon-counting and deconvolution techniques

    physics.app-ph 2024-11 conditional novelty 5.0 of 10

    A hybrid photon-counting and deconvolution pipeline improves the signal-to-noise ratio of energy-dispersive x-ray spectra in both low and high photon-density regimes.

Pith tools