Pith. sign in

REVIEW 1 cited by

Scalable, reproducible, and cost-effective processing of large-scale medical imaging datasets

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2408.14611 v1 pith:TQP3DVQQ submitted 2024-08-26 cs.DC cs.DB

classification cs.DCcs.DB
keywords dataprocessingcomputationlarge-scaledesignmethodstoragewhile
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Curating, processing, and combining large-scale medical imaging datasets from national studies is a non-trivial task due to the intense computation and data throughput required, variability of acquired data, and associated financial overhead. Existing platforms or tools for large-scale data curation, processing, and storage have difficulty achieving a viable cost-to-scale ratio of computation speed for research purposes, either being too slow or too expensive. Additionally, management and consistency of processing large data in a team-driven manner is a non-trivial task. We design a BIDS-compliant method for an efficient and robust data processing pipeline of large-scale diffusion-weighted and T1-weighted MRI data compatible with low-cost, high-efficiency computing systems. Our method accomplishes automated querying of data available for processing and process running in a consistent and reproducible manner that has long-term stability, while using heterogenous low-cost computational resources and storage systems for efficient processing and data transfer. We demonstrate how our organizational structure permits efficiency in a semi-automated data processing pipeline and show how our method is comparable in processing time to cloud-based computation while being almost 20 times more cost-effective. Our design allows for fast data throughput speeds and low latency to reduce the time for data transfer between storage servers and computation servers, achieving an average of 0.60 Gb/s compared to 0.33 Gb/s for using cloud-based processing methods. The design of our workflow engine permits quick process running while maintaining flexibility to adapt to newly acquired data.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Polyhedra Encoding Transformers: Enhancing Diffusion MRI Analysis Beyond Voxel and Volumetric Embedding

    eess.IV 2025-01 conditional novelty 5.0 of 10

    PE-Transformer resamples diffusion MRI signals onto an icosahedral grid and feeds them to a transformer, reporting small improvements in free water and fiber orientation estimation over CNN and vanilla transformer baselines.

Pith tools