Pith. sign in

REVIEW 2 cited by

Intrinsic geometry-inspired dependent toroidal distribution: Application to regression model for astigmatism data

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2409.06229 v1 pith:JGAO2KID submitted 2024-09-10 stat.AP

classification stat.AP
keywords distributiontoroidaldatadependentmodelastigmatismcardioidregression
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

This paper introduces a dependent toroidal distribution, to analyze astigmatism data following cataract surgery. Rather than utilizing the flat torus, we opt to represent the bivariate angular data on the surface of a curved torus, which naturally offers smooth edge identifiability and accommodates a variety of curvatures: positive, negative, and zero. Beginning with the area-uniform toroidal distribution on this curved surface, we develop a five-parameter-dependent toroidal distribution that harnesses its intrinsic geometry via the area element to model the distribution of two dependent circular random variables. We show that both marginal distributions are Cardioid, with one of the conditional variables also following a Cardioid distribution. This key feature enables us to propose a circular-circular regression model based on conditional expectations derived from circular moments. To address the high rejection rate (approximately 50%) in existing acceptance-rejection sampling methods for Cardioid distributions, we introduce an exact sampling method based on a probabilistic transformation. Additionally, we generate random samples from the proposed dependent toroidal distribution through suitable conditioning. This bivariate distribution and the regression model are applied to analyze astigmatism data arising in the follow-up of one and three months due to cataract surgery.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. On the spherical cardioid distribution and its goodness-of-fit

    stat.ME 2026-01 conditional novelty 6.0 of 10

    The spherical cardioid family on S^d, previously used only as an auxiliary construction, is given closed-form moments, convolution closure, asymptotically normal estimators, and a bootstrap goodness-of-fit test, with ...

  2. Semi-parametric least-area linear-circular regression through M\"{o}bius transformation

    stat.ME 2024-11 reject novelty 4.0 of 10

    The authors introduce a Möbius-link linear-circular regression with an area-based loss to estimate the timing of daily highs and lows in cryptocurrency data.

Pith tools