REVIEW 3 major objections 5 minor 91 references
A compact frozen-spin trap for the search for the electric dipole moment of the muon
T0 review · 3 major / 5 minor · reviewed 2026-08-09 · deepseek-v4-flash
Pith's one-line read By freezing the muon's spin precession, a compact solenoid trap aims to detect a muon electric dipole moment at sensitivities down to 6×10^-23 e·cm, a three-thousandfold improvement over the current direct limit.
desk verdict A serious, honest design study for a compact muon EDM experiment; the projected sensitivity is conditional on unvalidated injection efficiency. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The central object is the frozen-spin condition derived from the Thomas-BMT equation: a radial electric field E_f = aBcβγ² is tuned to zero the anomalous spin precession, leaving only EDM-driven precession ω_e = 2d_µ β c B/ℏ around the rest-frame electric field. The carrying mechanism is a compact 2.5 T solenoid (5 T in Phase II) with a weakly-focusing field, into which muons are longitudinally injected through magnetically shielded tubes and stopped by a pulsed magnetic kicker; a segmented ground/HV electrode pair supplies the radial E-field, and the CHeT fiber tracker measures the decay-positron asymmetry along and opposite to the B-field. The analysis uses an energy-threshold and angular-binned W-method to maximize the figure of merit F = ᾱ√(N_e+/N_µ+).
What would settle it
Commission the Phase I apparatus and measure the actual stored-muon rate and the residual spin-precession frequency as a function of the applied radial electric field; a stored rate well below 500/s, or a failure to observe the expected linear zero-crossing of the precession frequency at the predicted frozen-spin field, would invalidate the claimed sensitivity.
Extended reading notes
Core claim
This paper establishes the feasibility of a direct muon EDM search using a compact frozen-spin trap at a high-intensity surface-muon beamline. It claims that with 4×$10^{6}$ muons/s at 28 MeV/c, a stored rate of 500/s, and 200 days of data, statistics give σ(d) ≤ 4×$10^{-21}$ e·cm; with 1.2×$10^{8}$ muons/s at 125 MeV/c, a stored rate of $10^{5}$/s, the sensitivity reaches σ(d) ≤ 6×$10^{-23}$ e·cm. The underlying claim is that the frozen-spin condition E ≈ aBcβγ² can be realized and maintained well enough that systematic effects stay below statistical sensitivity, with the dominant systematic uncertainties controlled by alternating clockwise and counter-clockwise injection with magnetic-field reversal.
Load-bearing premise
The projected sensitivity scales as one over the square root of the number of stored muons, and the stored rates used in the projections rest on Monte-Carlo-simulated injection efficiencies (0.45% in Phase I) and channel transmission (3%) that have not yet been demonstrated in a real apparatus; if the achieved injection efficiency is lower, the sensitivity degrades proportionally.
Editorial extensions
If this is right
- If the design works, Phase I would improve the direct muon EDM limit of 1.8×10^-19 e·cm by about 45 times.
- Phase II would reach 6×10^-23 e·cm, probing phases of order one in the Wilson coefficient of the muon dipole operator in beyond-Standard-Model effective field theories.
- A null result would constrain scenarios with chiral enhancement and lepton-flavor symmetries that predict a large muon EDM.
- The demonstration would establish the frozen-spin technique in a compact storage trap as a general tool for charged-lepton EDM searches.
Reading between the lines
- If the simulated injection efficiency proves lower in practice, the Phase I sensitivity could still be recovered by extending the data-taking period, since the 200-day figure scales linearly with the stored-muon rate.
- The staged approach de-risks the measurement: Phase I's primary goal is to demonstrate the frozen-spin and injection methods, and only if that succeeds does the 3000-fold improvement of Phase II become plausible.
- The systematic budget leans heavily on the clockwise/counter-clockwise reversal; any residual difference in beam momentum or initial spin phase between the two injection modes is the main constraint on the final sensitivity.
- The same frozen-spin trap concept could be adapted to other charged particles with sufficiently long lifetimes or to a complementary search for the muon anomalous magnetic moment by detuning the electric field from the frozen-spin condition.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. This paper presents a conceptual design for a compact frozen-spin storage trap to search for the muon electric dipole moment at PSI. The experiment would store muons in a solenoidal magnetic field and apply a radial electric field tuned to the frozen-spin condition, so that the muon spin precesses only under the influence of an EDM. The manuscript derives the statistical sensitivity from the Thomas-BMT equation and Michel-decay kinematics, defines figures of merit for different analysis methods (simple counting, T-method, W-method), and describes the proposed Phase I and Phase II instrumentation: injection channels with magnetic shielding, a pulsed kicker, segmented frozen-spin electrodes, muon detectors, a positron tracker, and the DAQ system. The stated central claims are a Phase I statistical sensitivity of σ(d) ≤ 4×10^-21 e·cm in 200 days and a Phase II sensitivity of σ(d) ≤ 6×10^-23 e·cm. The paper also includes a systematic-effect table and references a companion paper for detailed spin-precession systematic studies.
Significance. If realized, the proposed experiment would improve the current direct muon EDM limit by a factor of about 45 in Phase I and about 3000 in Phase II, reaching a region of interest for several beyond-Standard-Model scenarios. The paper's main strengths are its transparent analytical framework: Appendix A gives a self-contained derivation of the statistical sensitivity, Section IIIA derives the analyzing-power figures of merit from Michel decay kinematics, and the design parameters are specified with enough detail to be simulated or checked. The manuscript also reports component-level prototype work (muon beam monitor, ToF detectors, entrance trigger, segmented electrodes, pulse-coil prototype), which lends credibility to the hardware concept. The central weakness is that the two efficiency numbers that convert the measured beam flux into a stored-muon rate—the channel transmission and the spiral-injection efficiency—are Monte-Carlo-derived and not yet experimentally validated; the paper itself labels the injection efficiency as a baseline 'subject to further refinement'.
major comments (3)
- [Eq. (5) and Appendix A, Eq. (A12)] The statistical-sensitivity formula printed as Eq. (5) is not the formula derived in Appendix A. Eq. (5) places N, γτ, and α~ together under a square root, σ(dμ) = ħ/(2P0βcB sqrt(N γτ α~)), whereas Eq. (A12) gives σ(dμ) = ħ/(2cβB α~ P) × 1/(γτ sqrt(N)), with α~ and γτ outside the square root. The main text states that Eq. (5) is used to obtain the quoted numbers, so the two must be reconciled: if Eq. (5) is intended, the scaling with N, lifetime, and analyzing power is different and the quoted Phase I/II sensitivities need to be re-derived; if Eq. (A12) is intended, Eq. (5) is a typographical error that must be corrected before publication.
- [Table I and Sec. IVB (Tables IV)] The central Phase I projection σ(d)≤4×10^-21 e·cm in 200 days is a statistical limit that scales as 1/sqrt(N). The assumed detected-positron rate N=400/s is the product of the measured 4×10^6/s beam flux and two Monte-Carlo-derived quantities: channel transmission of 0.03 and injection efficiency of 0.004 (Tables I and IV). The injection efficiency is explicitly described in Sec. IVB as a baseline 'subject to further refinement', and the solenoid field map used for the injection simulation was reconstructed by fitting a limited set of measured data to an ANSYS model (Sec. IVB1). No stored-muon rate has been demonstrated in a prototype or beam test. A factor-f shortfall in the injection efficiency degrades the Phase I sensitivity by sqrt(f); for example, a factor-4 shortfall moves the projection from 4×10^-21 to about 8×10^-21 e·cm. The paper should either provide an end-to-end validation of the storage rate or present the sensitivity as a simulation-conditioned projection with an explicit efficiency-uncertainty band instead of an unconditional 'expected sensitivity'.
- [Table III and Sec. IIIB] Table III lists expected values for many systematic-effect parameters—radial B-field of 5 µT at 100 kHz, azimuthal current below 10 mA, CW/CCW momentum difference of 0.2%, initial-polarization difference of 25 mrad, orbit displacement of 1 mm, and pitch below 1 mrad—and totals them to 0.75×10^-21 e·cm (Phase I) and 1.7×10^-23 e·cm (Phase II). Several of these entries are design targets rather than measured or otherwise demonstrated quantities, and the text does not state which entries have prototype validation. Since the conclusion claims the experiment is 'meeting the requirements to control systematic effects accordingly', the manuscript should distinguish requirements from validated capabilities and give, for each Table III row, the source of the expected value (measurement, simulation, or assumption).
minor comments (5)
- [Table I] The quoted detection rate and number of detections per 200 days are inconsistent: 400/s × 200 days = 6.9×10^9, not 5.8×10^9 as listed; the origin of the 16% reduction (dead time, duty factor, or analysis cuts) should be stated.
- [Eq. (3) and Sec. II.A] For γ≈1 the coefficient (a−1/(γ^2−1)) in Eq. (3) is negative, while the text immediately below writes E_f = aBcβγ^2 with a positive sign; the radial orientation or sign convention should be defined so that the two expressions agree.
- [Table IV] The units in Table IV mix current densities (A/mm^2) for the correction coils and weak-focusing coil with a total current (A) for the pulse coil; the table should state the geometry over which each current density is applied.
- [Sec. II.B] The text says single measurements are repeated 'about 400 times per second', while Table I lists a muon storage rate of 500/s and a positron detection rate of 400/s; the relationship between these three rates should be clarified.
- [Fig. 13 caption] The caption contains the typo 'anti-Helmoltz'; it should read 'anti-Helmholtz'.
Circularity Check
No significant circularity: the EDM sensitivity is a Poisson-scaled Thomas-BMT/Michel-decay projection, and its rate inputs are stated as simulated baselines rather than as quantities fitted to an EDM.
full rationale
The central sensitivity formula, Eq. (5) and its Appendix A derivation Eq. (A12), is derived from the Thomas-BMT precession equation and the Michel decay asymmetry; no EDM value, posterior, or fitted parameter enters the derivation. The frozen-spin condition, Eq. (3), is obtained algebraically from the Thomas-BMT equation, and the paper explicitly plans to set the electric field by measuring Omega(E_rho) and interpolating to zero, i.e., by calibration rather than by assuming the target EDM. The statistical reach sigma(d) <= 4e-21 e.cm does depend on N, the number of detected positrons, and N is built from the measured beam flux (4e6/s) times MC-derived channel transmission (3%) and injection efficiency (0.45%), which are labeled in Table I and Table IV as 'deduced in MC simulations' and 'baseline, subject to further refinement.' These are unvalidated performance assumptions, not fitted inputs disguised as predictions; if the real storage rate is lower, the sensitivity degrades as 1/sqrt(N), exactly as the paper's formula states. The self-citations (Refs. [51], [60], [71]) are supporting: the frozen-spin technique is also referenced to the external works [49,50], the systematic limits in Table III are delegated to a separately published EPJC study, and no load-bearing uniqueness theorem or ansatz is imported from the authors' prior work. Therefore no circular step is exhibited.
Assumptions & free parameters
free parameters (3)
- Phase I injection efficiency =
0.45% (baseline from MC)
- Phase I channel transmission =
3% (baseline from MC)
- T-method energy threshold u0 =
0.626 (Phase I), 0.183 (Phase II)
assumptions (5)
- domain assumption Thomas-BMT spin precession equation
- domain assumption Michel decay spectrum
- domain assumption Neglect of decoherence in sensitivity estimate
- domain assumption Zero correlation between forward and backward positron counts
- ad hoc to paper Achievability of systematic-effect limits
Cite this review
Pith. "Pith review of A compact frozen-spin trap for the search for the electric dipole moment of the muon." pith.science (2026). https://pith.science/paper/MPQ3AYDL
@misc{pith2026250118979,
author = {Pith},
title = {Pith review of: A compact frozen-spin trap for the search for the electric dipole moment of the muon},
year = {2026},
howpublished = {\url{https://pith.science/paper/MPQ3AYDL}},
note = {Machine review of arXiv:2501.18979}
}
abstract
The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.
Figures
Figures from the paper (22 more)
Reference graph
Works this paper leans on
-
[1]
The coils are made of multi-filament Nb-Ti cable and the magnetic field can reach5 T
Magnetic field For the demonstration experiments in Phase I we will use an existing superconducting solenoid, with mechanical bore dimensions of200 mmdiameter and 1000 mmlength. The coils are made of multi-filament Nb-Ti cable and the magnetic field can reach5 T. In addition to the principal solenoid coil, a split coil pair also made of Nb-Ti cancels seco...
2025
-
[2]
Magnetically shielded injection The muon transport into the solenoid bore is shielded from the fringe magnetic field along the two injection tubes to make deflection negligible and to maximize the muon transmission from the exit of the beam line. Baseline parameters for the magnetically shielded injection tubes are a diameterdinj = 15 mmand length ℓ = 800...
-
[3]
IVC, at the exit of the injection channels generates a trigger signal for every muon within the storage phase space
Magnetic field pulse A gate detector in combination with an active aperture, described in Sec. IVC, at the exit of the injection channels generates a trigger signal for every muon within the storage phase space. As the muons approach the storage region, their remaining longitudinal momentum,pz < 1 MeV/c, is significantly reduced from the initial value of ...
2025
-
[4]
Maximum Integrated Data Acquisition System
Frozen-spin electrodes The radial electric field will be applied using cylindrical concentric electrodes that surround the muon orbit atrb = 35 mm (grounded) andra = 25 mm (high voltage). A voltage of approximately1.8 kVwill be required so that the field strengthEf≈ 1.8 kV/cm is applied at the nominal orbit radius,ρ, to achieve the frozen-spin condition. ...
2000
-
[5]
G. Lüders. ‘Proof of the TCP theorem.’ Ann. Phys., 2(1957) 1. URL http://dx.doi.org/10.1016/ 0003-4916(57)90032-5
1957
-
[6]
M. Kobayashi and T. Maskawa. ‘CP Violation in the Renormalizable Theory of Weak Interaction.’ Prog. Theor. Phys., 49(1973) 652. URLhttp://dx.doi.org/10.1143/PTP.49.652
-
[7]
C. Jarlskog. ‘Commutatorof the QuarkMass Matrices in theStandard ElectroweakModel anda Measure of Max- imal CP Nonconservation.’ Phys. Rev. Lett., 55(1985) 1039. URLhttp://dx.doi.org/10.1103/PhysRevLett. 55.1039
-
[8]
Navaset al
S. Navaset al. ‘Review of particle physics.’ Phys. Rev. D, 110(2024) 030001. URLhttp://dx.doi.org/10. 1103/PhysRevD.110.030001
2024
Show all 91 references
-
[9]
Hocker, H
A. Hocker, H. Lacker, S. Laplace, and F. Le Diberder. ‘A New approach to a global fit of the CKM matrix.’ Eur. Phys. J. C, 21(2001) 225. URLhttp://dx.doi.org/10.1007/s100520100729. hep-ph/0104062
2001 arXiv
-
[10]
Bona et al
M. Bona et al. ‘The 2004 UTfit collaboration report on the status of the unitarity triangle in the standard model.’ JHEP, 07(2005) 028. URLhttp://dx.doi.org/10.1088/1126-6708/2005/07/028. hep-ph/0501199
2005 arXiv
-
[11]
Pospelov and A
M. Pospelov and A. Ritz. ‘CKM benchmarks for electron electric dipole moment experiments.’ Phys. Rev. D, 89(2014) 056006. URL http://dx.doi.org/10.1103/PhysRevD.89.056006. 1311.5537
2014 arXiv
-
[12]
C.-Y. Seng. ‘Reexamination of The Standard Model Nucleon Electric Dipole Moment.’ Phys. Rev. C, 91(2015) 025502. URL http://dx.doi.org/10.1103/PhysRevC.91.025502. 1411.1476
2015 arXiv
-
[13]
’t Hooft
G. ’t Hooft. ‘Symmetry Breaking through Bell-Jackiw Anomalies.’ Phys. Rev. Lett., 37(1976) 8. URLhttp: //dx.doi.org/10.1103/PhysRevLett.37.8
1976 doi
-
[14]
C. Abel, S. Afach, N. J. Ayres,et al. ‘Measurement of the Permanent Electric Dipole Moment of the Neutron.’ Phys. Rev. Lett., 124(2020) 081803. URLhttp://dx.doi.org/10.1103/physrevlett.124.081803
2020 doi
-
[15]
R. J. Crewther, P. Di Vecchia, G. Veneziano, and E. Witten. ‘Chiral Estimate of the Electric Dipole Moment of the Neutron in Quantum Chromodynamics.’ Phys. Lett. B, 88(1979) 123. URLhttp://dx.doi.org/10.1016/ 0370-2693(79)90128-X. [Erratum: Phys. Lett. B91, 487 (1980)]
1979
-
[16]
Dragos, T
J. Dragos, T. Luu, A. Shindler,et al.‘Confirming the Existence of the strong CP Problem in Lattice QCD with the Gradient Flow.’ Phys. Rev. C, 103(2021) 015202. URLhttp://dx.doi.org/10.1103/PhysRevC.103.015202. 1902.03254
2021 arXiv
-
[17]
Alexandrou, A
C. Alexandrou, A. Athenodorou, K. Hadjiyiannakou, and A. Todaro. ‘Neutron electric dipole moment using lattice QCD simulations at the physical point.’ Phys. Rev. D, 103(2021) 054501. URLhttp://dx.doi.org/10. 1103/PhysRevD.103.054501. 2011.01084
2021
-
[18]
Bhattacharya, V
T. Bhattacharya, V. Cirigliano, R. Gupta,et al. ‘Contribution of the QCD Θ-term to the nucleon electric dipole moment.’ Phys. Rev. D, 103(2021) 114507. URL http://dx.doi.org/10.1103/PhysRevD.103.114507. 2101.07230
2021 arXiv
-
[19]
Ghosh and R
D. Ghosh and R. Sato. ‘Lepton electric dipole moment and strong CP violation.’ Phys. Lett. B, 777(2018) 335. URL http://dx.doi.org/https://doi.org/10.1016/j.physletb.2017.12.052
2018 doi
-
[20]
A. D. Sakharov. ‘Violation of CP invariance, C asymmetry, and baryon asymmetry of the Universe.’ JETP Lett., 5(1967) 24. URL http://dx.doi.org/10.1070/PU1991v034n05ABEH002497
1967 doi
-
[21]
J. H. Smith, E. M. Purcell, and N. F. Ramsey. ‘Experimental Limit to the Electric Dipole Moment of the Neutron.’ Phys. Rev., 108(1957) 120. URLhttp://dx.doi.org/10.1103/PhysRev.108.120
1957 doi
-
[22]
Berley, R
D. Berley, R. L. Garwin, G. Gidal, and L. M. Lederman. ‘Electric Dipole Moment of the Muon.’ Phys. Rev. Lett., 1(1958) 144. URLhttp://dx.doi.org/10.1103/PhysRevLett.1.263.3
1958 doi
-
[23]
Jungmann
K. Jungmann. ‘Searching for electric dipole moments.’ Ann. Phys., 525(2013) 550
2013
-
[24]
T. E. Chupp, P. Fierlinger, M. J. Ramsey-Musolf, and J. T. Singh. ‘Electric dipole moments of atoms, molecules, nuclei, and particles.’ Rev. Mod. Phys., 91(2019) 015001. URLhttp://dx.doi.org/10.1103/RevModPhys.91. 015001
2019 doi
-
[25]
W. B. Cairncross and J. Ye. ‘Atoms and molecules in the search for time-reversal symmetry violation.’ Nat. Rev. Phys., 1(2019) 510. URLhttp://dx.doi.org/10.1038/s42254-019-0080-0. 30
2019 doi
-
[26]
Cirigliano, B
V. Cirigliano, B. Grinstein, G. Isidori, and M. B. Wise. ‘Minimal flavor violation in the lepton sector.’ Nucl. Phys. B, 728(2005) 121. URLhttp://dx.doi.org/10.1016/j.nuclphysb.2005.08.037. hep-ph/0507001
2005 arXiv
-
[27]
R. S. Chivukula, H. Georgi, and L. Randall. ‘A Composite Technicolor Standard Model of Quarks.’ Nucl. Phys. B, 292(1987) 93. URLhttp://dx.doi.org/10.1016/0550-3213(87)90638-9
1987 doi
-
[28]
L. J. Hall and L. Randall. ‘Weak scale effective supersymmetry.’ Phys. Rev. Lett., 65(1990) 2939. URL http://dx.doi.org/10.1103/PhysRevLett.65.2939
1990 doi
-
[29]
A.J.Buras, P.Gambino, M.Gorbahn, et al.‘Universalunitaritytriangleandphysicsbeyondthestandardmodel.’ Phys. Lett. B, 500(2001) 161. URLhttp://dx.doi.org/10.1016/S0370-2693(01)00061-2. hep-ph/0007085
2001 arXiv
-
[30]
D’Ambrosio, G
G. D’Ambrosio, G. F. Giudice, G. Isidori, and A. Strumia. ‘Minimal flavor violation: An Effective field theory approach.’ Nucl. Phys. B, 645(2002) 155. URL http://dx.doi.org/10.1016/S0550-3213(02)00836-2. hep- ph/0207036
2002
-
[31]
T. S. Roussy, L. Caldwell, T. Wright,et al. ‘An improved bound on the electron’s electric dipole moment.’ Science, 381(2023) 46. URLhttp://dx.doi.org/10.1126/science.adg4084. 2212.11841
2023 arXiv
-
[32]
Crivellin, M
A. Crivellin, M. Hoferichter, and P. Schmidt-Wellenburg. ‘Combined explanations of (g-2)µ,e and implications for a large muon EDM.’ Phys. Rev. D, 98(2018) 113002. URLhttp://dx.doi.org/10.1103/PhysRevD.98.113002. 1807.11484
2018 arXiv
-
[33]
D. P. Aguillardet al. ‘Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm.’ Phys. Rev. Lett., 131(2023) 161802. URLhttp://dx.doi.org/10.1103/PhysRevLett.131.161802. 2308.06230
2023
-
[34]
D. P. Aguillardet al. ‘Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm.’ Phys. Rev. D, 110(2024) 032009. URL http://dx.doi.org/10.1103/PhysRevD.110.032009. 2402.15410
2024
-
[35]
Aoyama, N
T. Aoyama, N. Asmussen, M. Benayoun,et al. ‘The anomalous magnetic moment of the muon in the Standard Model.’ Phys. Rep., 887(2020) 1. URLhttp://dx.doi.org/10.1016/j.physrep.2020.07.006. 2006.04822
2020 arXiv
-
[36]
Colangeloet al
G. Colangeloet al. ‘Prospects for precise predictions ofaµ in the Standard Model.’ (2022). 2203.15810
2022 arXiv
-
[37]
J. L. Feng, K. T. Matchev, and Y. Shadmi. ‘Theoretical expectations for the muon’s electric dipole moment.’ Nucl. Phys., B613(2001) 366. URLhttp://dx.doi.org/10.1016/S0550-3213(01)00383-2. hep-ph/0107182
2001 arXiv
-
[38]
X. G. He, G. C. Joshi, H. Lew, and R. R. Volkas. ‘NEW Z-prime PHENOMENOLOGY.’ Phys. Rev. D, 43(1991)
1991
-
[39]
URL http://dx.doi.org/10.1103/PhysRevD.43.R22
-
[40]
R. Foot. ‘New Physics From Electric Charge Quantization?’ Mod. Phys. Lett. A, 6(1991) 527. URLhttp: //dx.doi.org/10.1142/S0217732391000543
1991 doi
-
[41]
X.-G. He, G. C. Joshi, H. Lew, and R. R. Volkas. ‘Simplest Z-prime model.’ Phys. Rev. D, 44(1991) 2118. URL http://dx.doi.org/10.1103/PhysRevD.44.2118
1991 doi
-
[42]
Altmannshofer, M
W. Altmannshofer, M. Carena, and A. Crivellin. ‘Lµ− Lτ theory of Higgs flavor violation and(g− 2)µ.’ Phys. Rev. D, 94(2016) 095026. URLhttp://dx.doi.org/10.1103/PhysRevD.94.095026. 1604.08221
2016 arXiv
-
[43]
Bigaran and R
I. Bigaran and R. R. Volkas. ‘Reflecting on chirality: CP-violating extensions of the single scalar-leptoquark solutions for the (g-2)e,µ puzzles and their implications for lepton EDMs.’ Phys. Rev. D, 105(2022) 015002. URL http://dx.doi.org/10.1103/PhysRevD.105.015002. 2110.03707
2022 arXiv
-
[44]
Crivellin and M
A. Crivellin and M. Hoferichter. ‘Consequences of chirally enhanced explanations of (g− 2)µ for h→ µµ and Z → µµ.’ JHEP, 07(2021) 135. URLhttp://dx.doi.org/10.1007/JHEP07(2021)135. [Erratum: JHEP 10, 030 (2022)], 2104.03202
2021 arXiv
-
[45]
G. M. Pruna. ‘Leptonic CP violation in the charged sector and effective field theory approach.’ PoS, FPCP2017(2017) 016. URL http://dx.doi.org/10.22323/1.304.0016. 1710.08311
2017 arXiv
-
[46]
Crivellin and M
A. Crivellin and M. Hoferichter. ‘Combined explanations of (g− 2)µ, (g− 2)e and implications for a large muon EDM.’ arXiv e-prints, (2019) arXiv:1905.03789. URL https://ui.adsabs.harvard.edu/abs/ 2019arXiv190503789C. 1905.03789
2019 arXiv
-
[47]
G. W. Bennett, B. Bousquet, H. N. Brown,et al. ‘Improved limit on the muon electric dipole moment.’ Phys. Rev. D, 80(2009) 052008. URLhttp://dx.doi.org/10.1103/PhysRevD.80.052008. 0811.1207
2009 arXiv
-
[48]
Andreev, D
V. Andreev, D. Ang, D. DeMille,et al. ‘Improved limit on the electric dipole moment of the electron.’ Nature, 562(2018) 355. URL http://dx.doi.org/10.1038/s41586-018-0599-8
2018 doi
-
[49]
Inamiet al
K. Inamiet al. ‘An improved search for the electric dipole moment of theτ lepton.’ JHEP, 04(2022) 110. URL http://dx.doi.org/10.1007/JHEP04(2022)110. 2108.11543
2022 arXiv
-
[50]
Bernabéu, G
J. Bernabéu, G. A. González-Sprinberg, and J. Vidal. ‘CP violation and electric-dipole-moment at low energy tau production with polarized electrons.’ Nucl. Phys. B, 763(2007) 283. URLhttp://dx.doi.org/10.1016/j. nuclphysb.2006.11.023. hep-ph/0610135
2007 arXiv
-
[51]
Crivellin, M
A. Crivellin, M. Hoferichter, and J. M. Roney. ‘Toward testing the magnetic moment of the tau at one part per million.’ Phys.Rev.D,106(2022)093007. URL http://dx.doi.org/10.1103/PhysRevD.106.093007. 2111.10378
2022 arXiv
-
[52]
A. G. Grozin, I. B. Khriplovich, and A. S. Rudenko. ‘Electric dipole moments, from e to tau.’ Phys. Atom. Nucl., 72(2009) 1203. URLhttp://dx.doi.org/10.1134/S1063778809070138. 0811.1641
2009 arXiv
-
[53]
Y. Ema, T. Gao, and M. Pospelov. ‘Improved Indirect Limits on Muon Electric Dipole Moment.’ Phys. Rev. Lett., 128(2022) 131803. URLhttp://dx.doi.org/10.1103/PhysRevLett.128.131803. 2108.05398
2022 arXiv
-
[54]
I. B. Khriplovich. ‘Feasibility of search for nuclear electric dipole moments at ion storage rings.’ Phys. Lett. B, 444(1998) 98. URL http://dx.doi.org/10.1016/S0370-2693(98)01353-7. hep-ph/9809336
1998 arXiv
-
[55]
F. J. M. Farley, K. Jungmann, J. P. Miller,et al. ‘A New method of measuring electric dipole moments in storage rings.’ Phys. Rev. Lett., 93(2004) 052001. URLhttp://dx.doi.org/10.1103/PhysRevLett.93.052001. hep-ex/0307006
2004 arXiv
-
[56]
Adelmann, K
A. Adelmann, K. Kirch, C. J. G. Onderwater, and T. Schietinger. ‘Compact storage ring to search for the muon electric dipole moment.’ J. Phys. G, 37(2010) 085001. URL http://dx.doi.org/10.1088/0954-3899/37/8/ 085001. 31
2010 doi
-
[57]
D. Barna. ‘High field septum magnet using a superconducting shield for the Future Circular Collider.’ Phys. Rev. Acc. Beams, 20(2017) 041002. URLhttp://dx.doi.org/10.1103/PhysRevAccelBeams.20.041002
2017 doi
-
[58]
Graner, Y
B. Graner, Y. Chen, E. G. Lindahl, and B. R. Heckel. ‘Reduced Limit on the Permanent Electric Dipole Moment of Hg199.’ Phys. Rev. Lett., 116(2016) 161601. 1601.04339
2016 arXiv
-
[59]
N. J. Ayres, G. Ban, L. Bienstman,et al.‘The design of the n2EDM experiment.’ Eur. Phys. J. C, 81(2021) 512. URL http://dx.doi.org/10.1140/epjc/s10052-021-09298-z
2021 doi
-
[60]
N. F. Ramsey. ‘A Molecular Beam Resonance Method with Separated Oscillating Fields.’ Phys. Rev., 78(1950) 695
1950
-
[61]
L. Thomas. ‘I. The kinematics of an electron with an axis.’ The London, Edinburgh, and Dublin Phil. Mag. Jour. Sci., 3(1927) 1. URLhttp://dx.doi.org/10.1080/14786440108564170
1927 doi
-
[62]
Bargmann, L
V. Bargmann, L. Michel, and V. L. Telegdi. ‘Precession of the Polarization of Particles Moving in a Homogeneous Electromagnetic Field.’ Phys. Rev. Lett., 2(1959) 435. URLhttp://dx.doi.org/10.1103/PhysRevLett.2.435
1959 doi
-
[63]
M.Abe, S.Bae, G.Beer, et al.‘Anewapproachformeasuringthemuonanomalousmagneticmomentandelectric dipole moment.’ Prog. Theo. Exp. Phys., 2019(2019) 053C02. URLhttp://dx.doi.org/10.1093/ptep/ptz030. 1901.03047
2019 arXiv
-
[64]
B. Abi, T. Albahri, S. Al-Kilani,et al. ‘Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm.’ Phys. Rev. Lett., 126(2021) 141801. URLhttp://dx.doi.org/10.1103/PhysRevLett.126.141801
2021 doi
-
[65]
Adelmann, M
A. Adelmann, M. Backhaus, C. Chavez Barajas, et al. ‘Search for a muon EDM using the frozen-spin technique.’ PSI Letter Of Intent, (2021) arXiv:2102.08838. URL https://ui.adsabs.harvard.edu/abs/ 2021arXiv210208838A. 2102.08838
2021 arXiv
-
[66]
W. B. Dress, P. D. Miller, J. M. Pendlebury,et al. ‘Search for an electric dipole moment of the neutron.’ Phys. Rev. D, 15(1977) 9. URLhttp://dx.doi.org/10.1103/PhysRevD.15.9
1977 doi
-
[67]
Iinuma, H
H. Iinuma, H. Nakayama, K. Oide,et al.‘Three-dimensional spiral injection scheme for the g-2/EDM experiment at J-PARC.’ Nucl. Instr. Meth. Phys. Res. A, 832(2016) 51. URLhttp://dx.doi.org/10.1016/j.nima.2016. 05.126
2016 doi
-
[68]
L. Michel. ‘Interaction between Four Half-Spin Particles and the Decay of theµ-Meson.’ Proc. Phys. Soc. A, 63(1950) 514. URL http://dx.doi.org/10.1088/0370-1298/63/5/311
1950 doi
-
[69]
Bouchiat and L
C. Bouchiat and L. Michel. ‘Theory ofµ-Meson Decay with the Hypothesis of Nonconservation of Parity.’ Phys. Rev., 106(1957) 170. URLhttp://dx.doi.org/10.1103/PhysRev.106.170
1957 doi
-
[70]
Kinoshita and A
T. Kinoshita and A. Sirlin. ‘Polarization of Electrons in Muon Decay with General Parity-Nonconserving Inter- actions.’ Phys. Rev., 108(1957) 844. URLhttp://dx.doi.org/10.1103/PhysRev.108.844
1957 doi
-
[71]
Kinoshita and A
T. Kinoshita and A. Sirlin. ‘Radiative Corrections to Fermi Interactions.’ Phys. Rev., 113(1959) 1652. URL http://dx.doi.org/10.1103/PhysRev.113.1652
1959 doi
-
[72]
Banerjee, A
P. Banerjee, A. Coutinho, T. Engel,et al. ‘High-precision muon decay predictions for ALP searches.’ SciPost Phys., 15(2023) 021. URLhttp://dx.doi.org/10.21468/SciPostPhys.15.1.021
2023 doi
-
[73]
L. S. Brown and G. Gabrielse. ‘Precision spectroscopy of a charged particle in an imperfect Penning trap.’ Phys. Rev. A, 25(1982) 2423. URLhttp://dx.doi.org/10.1103/PhysRevA.25.2423
1982 doi
-
[74]
J. M. Pendlebury, W. Heil, Y. Sobolev,et al. ‘Geometric-phase-induced false electric dipole moment signals for particles in traps.’ Phys. Rev. A, 70(2004) 032102. URLhttp://dx.doi.org/10.1103/PhysRevA.70.032102
2004 doi
-
[75]
M. V. Berry. ‘Quantal phase factors accompanying adiabatic changes.’ Proc. Roy. Soc. Lond., A392(1984) 45. URL http://dx.doi.org/10.1098/rspa.1984.0023
1984
-
[76]
Cavoto, R
G. Cavoto, R. Chakraborty, A. Doinaki,et al. ‘Anomalous spin precession systematic effects in the search for a muon EDM using the frozen-spin technique.’ Eur. Phys. J. C, 84(2024). URLhttp://dx.doi.org/10.1140/ epjc/s10052-024-12604-0
2024
-
[77]
Sedlak, R
K. Sedlak, R. Scheuermann, T. Shiroka,et al. ‘MusrSim and MusrSimAna - Simulation Tools forµSR Instru- ments.’ Phys. Proc., 30(2012) 61. URLhttp://dx.doi.org/10.1016/j.phpro.2012.04.040
2012 doi
-
[78]
Agostinelli, J
S. Agostinelli, J. Allison, K. Amako,et al. ‘Geant4—a simulation toolkit.’ Nucl. Instr. Meth. Phys. Res. A, 506(2003) 250. URL http://dx.doi.org/10.1016/s0168-9002(03)01368-8
2003 doi
-
[79]
Roberts, K
T. Roberts, K. Beard, S. Ahmed,et al.‘G4beamline Particle Tracking in Matter Dominated Beam Lines.’ Conf. Proc. C, 110328(2011) 373
2011
-
[80]
K. Deb, A. Pratap, S. Agarwal, and T. Meyarivan. ‘A fast and elitist multiobjective genetic algorithm: NSGA-II.’ IEEE Trans. Evo. Comp., 6(2002) 182. URLhttp://dx.doi.org/10.1109/4235.996017
2002
-
[81]
A. Papa, F. Barchetti, F. Gray, et al. ‘A multi-purposed detector with silicon photomultiplier readout of scintillating fibers.’ Nucl. Instr. Meth. Phys. Res. A, 787(2015) 130 . URLhttp://dx.doi.org/https://doi. org/10.1016/j.nima.2014.11.074. New Developments in Photodetection NDIP14
2015 doi
-
[82]
M. Sakurai. Towards a Search for the Muon Electric Dipole Moment using the Frozen-Spin Technique. Ph.D. thesis, ETH Zürich (2022). DISS. ETH NO. 28992
2022
-
[83]
H. Noma, T. Shioda, and Y. Yoshizawa. ‘Circular hole iron septum magnet.’ Nucl. Instr. Meth., 184(1981) 587. URL http://dx.doi.org/10.1016/0029-554X(81)90769-2
1981 doi
-
[84]
Barna, M
D. Barna, M. Novák, K. Brunner,et al. ‘NbTi/Nb/Cu multilayer shield for the superconducting shield (SuShi) septum.’ IEEE Trans. Appl. Supercond., 29(2018) 4900108. URL http://dx.doi.org/10.1109/TASC.2018. 2872860. 1809.04330
2018 arXiv
-
[85]
Nagasaki, M
Y. Nagasaki, M. Solovyov, and F. Gomory. ‘Experimental and Numerical Investigation of Shielding Perfor- mance of Superconducting Magnetic Shields Using Coated Conductor Tapes.’ IEEE Transactions on Applied Superconductivity, 28(2018) 2808374. URLhttp://dx.doi.org/10.1109/TASC....
2018
-
[86]
Doinaki, C
A. Doinaki, C. Calzolaio, R. Chakraborty, et al. ‘Superconducting shield for the injection channel of the muEDM experiment at PSI.’ Jour. Instr., 18(2023) C10011. URL http://dx.doi.org/10.1088/1748-0221/ 18/10/C10011. 32
2023 doi
-
[87]
B. Shen, F. Grilli, and T. Coombs. ‘Overview of H-Formulation: A Versatile Tool for Modeling Electromagnetics in High-Temperature Superconductor Applications.’ IEEE Access, 8(2020) 100403. URLhttp://dx.doi.org/ 10.1109/ACCESS.2020.2996177
2020
-
[88]
Llopart, R
X. Llopart, R. Ballabriga, M. Campbell,et al. ‘Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements.’ Nucl. Instr. Meth. Phys. Res. A, 581(2007) 485. URL http://dx.doi.org/10.1016/j.nima.2007.08.079
2007 doi
-
[89]
Giomataris, P
Y. Giomataris, P. Rebourgeard, J. Robert, and G. Charpak. ‘MICROMEGAS: a high-granularity position- sensitive gaseous detector for high particle-flux environments.’ Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associ...
1996 doi
-
[90]
Hiller, K
G. Hiller, K. Huitu, T. Ruppell, and J. Laamanen. ‘A Large Muon Electric Dipole Moment from Flavor?’ Phys. Rev. D, 82(2010) 093015. URLhttp://dx.doi.org/10.1103/PhysRevD.82.093015. 1008.5091
2010 arXiv
-
[91]
Hiller, C
G. Hiller, C. Hormigos-Feliu, D. F. Litim, and T. Steudtner. ‘Model building from asymptotic safety with Higgs and flavor portals.’ Phys. Rev. D, 102(2020) 095023. URLhttp://dx.doi.org/10.1103/PhysRevD.102.095023. 2008.08606. 33 Appendix A: Derivation of the statistical sensit...
2020 arXiv
Reviewed August 9, 2026 · model on record in the stance chip above.