Laboratory evaluation of a wearable instrumented headband for rotational head kinematics measurement

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2504.01939 v1 pith:PLS4ENW6 submitted 2025-04-02 eess.SP

classification eess.SP
keywords headbandinstrumentedrotationalheadkinematicsmouthguardssocceralternative
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Mild traumatic brain injuries (mTBI) are a highly prevalent condition with heterogeneous outcomes between individuals. A key factor governing brain tissue deformation and the risk of mTBI is the rotational kinematics of the head. Instrumented mouthguards are a widely accepted method for measuring rotational head motions, owing to their robust sensor-skull coupling. However, wearing mouthguards is not feasible in all situations, especially for long-term data collection. Therefore, alternative wearable devices are needed. In this study, we present an improved design and data processing scheme for an instrumented headband. Our instrumented headband utilizes an array of inertial measurement units (IMUs) and a new data-processing scheme based on continuous wavelet transforms to address sources of error in the IMU measurements. The headband performance was evaluated in the laboratory on an anthropomorphic test device, which was impacted with a soccer ball to replicate soccer heading. When comparing the measured peak rotational velocities (PRV) and peak rotational accelerations (PRA) between the reference sensors and the headband for impacts to the front of the head, the correlation coefficients (r) were 0.80 and 0.63, and the normalized root mean square error (NRMSE) values were 0.20 and 0.28, respectively. However, when considering all impact locations, r dropped to 0.42 and 0.34 and NRMSE increased to 0.5 and 0.41 for PRV and PRA, respectively. This new instrumented headband improves upon previous headband designs in reconstructing the rotational head kinematics resulting from frontal soccer ball impacts, providing a potential alternative to instrumented mouthguards.

Discussion (0). Continue with ORCID to comment.

Pith tools