REVIEW 4 major objections 5 minor 166 references
Guided progressive reconstructive imaging: a new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography
T0 review · 4 major / 5 minor · reviewed 2026-08-03 · deepseek-v4-flash
Pith's one-line read The paper claims that direct ptychographic phase retrieval reduces to a linear shift-and-add of precomputed guide functions, one per detected electron.
desk verdict Sound and novel event-wise reformulation of WDD, but the real-time linear-complexity claim rides on an integer scan grid the paper acknowledges is fragile, and the asserted identity to conventional WDD is never demonstrated numerically. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing object is the guide-function library G_qd(r): a set of kernel-limited, complex-valued distributions, one per detector pixel, precomputed from the probe's Wigner distribution (aperture, aberration, wavelength) and the detector MTF via a Wiener-filtered inversion. Each detected event contributes one such kernel shifted to the event's scan position; the whole reconstruction is the cumulative sum, with a normalization by the number of counts per scan position. This converts the conventional work of Fourier-transforming full frames and deconvolving in phase space into a per-event table lookup and addition, giving linear complexity in the number of events and decoupling the recons
What would settle it
Run a WDD reconstruction on an experimental dataset acquired with an event-driven detector on a non-integer or distorted scan grid, and compare the GPRI result with a conventional WDD reconstruction from the same events. If the two diverge by more than numerical precision without FFT-based interpolation, or if the processing time no longer scales linearly with event count, the central equivalence claim fails in practice.
Extended reading notes
Core claim
On the paper's own terms, the core discovery is that a single count at detector pixel qd and scan position rs contains enough information to update the reconstruction by a known, specimen-independent quantity: the contribution equals G_qd(r − rs), where G_qd is derived solely from the known illumination (aperture, aberrations, wavelength) and the detector's modulation transfer function. Because the WDD reconstruction is linear in the intensity, summing these contributions event-by-event reproduces exactly the result of the conventional collective Wigner-deconvolution treatment. The paper derives the guide-function library in Eq. (18), shows the summation forms in Eqs. (20)–(22), and verifies
Load-bearing premise
The strongest practical premise is that the scan raster consists of a uniform grid whose step is an integer multiple of the reconstruction pixel; if real scan positions drift off this grid (microscope distortions, beam drift, fly-back, or non-grid scans), the fast shift-and-add path breaks down and the method loses its real-time advantage.
Editorial extensions
If this is right
- A WDD ptychographic reconstruction can be produced progressively as events arrive, so the estimate improves continuously and can be displayed in real time during acquisition.
- Because the library is specimen-independent, the same precomputed kernels serve any dataset acquired under the same illumination, eliminating per-dataset heavy transforms.
- Reconstruction cost scales linearly with the number of events and scan positions, removing the nonlinear N² or N log N bottleneck that limits field of view in direct ptychography.
- The method admits count-wise, frame-based, or hybrid data formats through the same additive pipeline, and extends to sideband integration and integrated center-of-mass imaging.
- Low-dose performance matches conventional direct approaches: interpretable contrast is demonstrated in simulation down to about 10 e−/Ų.
Reading between the lines
- Editorial extension: the shift-and-add structure suggests that any linear direct-reconstruction scheme could be compiled into a kernel library, so future instrument-specific optimizations could be pushed entirely into library precomputation.
- Editorial extension: because each event contributes independently, the approach naturally supports streaming and distributed processing across many cores without inter-event communication — a property the paper notes but does not demonstrate.
- Editorial extension: the integer-scan-step restriction implies the practical payoff depends on scan-raster fidelity; combining the method with live scan-position correction (via beam-current or drift monitoring) would be a direct testable extension.
- Editorial extension: the guide-function profiles show that near-aperture scattering vectors carry the most noise-robust information, which quantifies which detector annuli matter most for low-dose experiments and could guide detector design.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript introduces 'guided progressive reconstructive imaging' (GPRI), a reformulation of analytical ptychography in which the reconstruction is built by cumulatively adding precomputed, specimen-independent guide functions, one per detected event or per detector pixel. The derivation starts from the standard WDD relation (Eq. 14), inserts a single-count intensity modeled as a product of Dirac deltas (Eq. 15), and obtains a guide-function library G_WDD_qd(r) (Eqs. 17–18). The whole reconstruction is then expressed as a shift-and-add sum over scan positions and detector events (Eqs. 20–22). The paper claims O(events) complexity, no dense frame storage, progressive/immediate feedback, and identical results to conventional WDD. Validation is by multislice simulations of a poliovirus at doses down to about 10 e⁻/Ų, using a 144×144 perfectly aligned raster. The appendix extends the same library idea to SBI and iCoM.
Significance. The mathematical reduction is elegant and appears internally consistent. If the equivalence to conventional WDD is exact up to normalization and pixelization, the event-wise shift-and-add formulation is a genuinely useful algorithmic insight: it decouples the reconstruction from FFT-based scan-to-frequency transforms and makes the cost linear in the number of events. The precomputed kernel-limited library is a practical strength, and the extension to SBI/iCoM broadens the impact. However, the headline claims of real-time, low-dose, large-field-of-view imaging are only partially supported: the real-time capability is not measured here and is delegated to ref. [33]; the low-dose demonstration is qualitative; and the linear-complexity advantage hinges on an integer-aligned scan raster that is not robust to drift or non-Cartesian scan paths.
major comments (4)
- [§3.1] This section states that the ratio of the scan step to the reconstruction pixel size 'has to be a integer', and that otherwise 'FFT-based shifting becomes necessary, which defeats the purpose of the wider algorithm.' This condition is load-bearing for the O(events) real-time claim. Real event-driven acquisitions include beam drift, flyback, and non-uniform scan paths, all of which produce scan positions that are not exact integer multiples of the reconstruction pixel. No simulation or experiment with a perturbed, drifted, or non-Cartesian raster is presented; the only demonstration is a perfectly aligned 144×144 grid. The authors should either provide a quantitative analysis of the cost and accuracy of an interpolation/FFT fallback, or explicitly restrict the real-time/linear-complexity claims to integer-aligned rasters.
- [Conclusion and §3.3] The conclusion claims 'a result identical to that of a conventional WDD implementation was obtained', but this is not supported by the evidence shown. Figure 4 displays GPRI reconstructions for several doses, but no side-by-side comparison with a conventional WDD reconstruction of the same simulated data, no difference map, and no error metric (e.g., SSIM, RMS error, or Fourier ring correlation) are provided. Since exact equivalence is a central claim, a quantitative comparison should be supplied.
- [§3.3 and §4.2] The dose-efficiency conclusion rests on visual inspection of Fig. 4. The text states that results show 'the same stability against noise as demonstrated by existing workflows', but no quantitative comparison with conventional WDD, SBI, or iterative methods is made. Likewise, the real-time throughput claim ('processing speed high enough to surpass the acquisition bandwidth', §4.2) is not measured anywhere in this manuscript; it is delegated to ref. [33]. Please include at least a timing/memory benchmark of the GPRI update loop, or soften the claims to statements about algorithmic complexity.
- [Eqs. (20) and (21)] The pattern-wise normalization in Eq. (20) divides by n(r_s), the number of counts at scan position r_s. In the low-dose regime that is central to the paper, many scan positions will have n(r_s)=0, and the formula as written is undefined there. The authors should specify the convention for empty scan positions (e.g., omit them from the sum or define 0/0=0) and demonstrate that this convention does not bias the result.
minor comments (5)
- [§3.1] 'the ratio of the scan step over it has to be a integer' should read 'an integer'.
- [§2.4] The sentence 'thus by a simple summation of individual qd-selected and rs-shifted guide functions G_WDD_qd(r), was also devised in subsection 1.3' is grammatically incomplete; please revise for clarity.
- [Fig. 3 caption] 'The exception is the case of a)' should be 'the case of panel (a)'.
- [Appendix, Eqs. (25) and (27)] The notation \tilde{G}^{SBI}_{q_d}(r) mixes Fourier-domain tilde notation with a real-space argument r. Please clarify which quantity is defined in which space.
- [§1.3, Eq. (4)] The claim that 'an additive cumulation of the contributions then leads to the same result as a collective treatment' is introduced before the WDD-specific definition of ΔT. It would help to state explicitly the class of reconstruction operators for which this linearity holds.
Circularity Check
No significant circularity: the event-wise GPRI result is a linear rearrangement of the established WDD Wiener filter, not an input-equivalent prediction.
full rationale
The central equivalence is derived by substitution, not assumed: Eqs. (15)-(16) insert a single-count delta into the established WDD phase-space relation (Eq. 14, from the original WDD literature), and Eq. (18) defines the guide function as the resulting illumination-only kernel. Because Eq. (14) is linear in the reformed data J, Eqs. (20)-(22) follow by direct summation; the 'additive cumulation ... same result as a collective treatment' claim in Eq. (4) is an algebraic consequence of linearity, not a fitted or self-defined outcome. The simulations use abTEM multislice data and an external poliovirus structure, so the reconstruction target is not an input to the library calculation. The integer scan-step condition in Sec. 3.1 is a practical constraint on the linear-complexity implementation, not a circular step; the paper explicitly states that non-integer ratios force FFT-based shifting and defeat the algorithm's purpose. The main references to the authors' own prior work ([33], [40], [100]) support the event-driven acquisition platform, the Wiener-parameter and normalization choices, and the patent-named framework; none of those citations supplies the mathematical equivalence itself. The conclusion's assertion of identity with conventional WDD is not backed by a quantitative side-by-side comparison, but that is a verification gap, not circularity.
Assumptions & free parameters
free parameters (4)
- Wiener parameter epsilon =
1e-6
- Final kernel radius for count updates =
8 x Abbe radius, with Hann window
- Initial calculation radius for library =
16 x Abbe radius
- Scattering-vector cutoff =
4 q_A
assumptions (7)
- domain assumption Phase object approximation T(r0) = exp(i phi(r0))
- domain assumption Fully coherent, aperture-limited probe with known aberration function
- domain assumption Multiplicative interaction model Psi = P * T
- standard math Wigner-distribution deconvolution relation Eq (12)/(14)
- domain assumption Single detected electron represented by a Dirac delta in (rs, qd)
- ad hoc to paper Scan positions lie on a uniform integer-aligned grid
- domain assumption Experimental intensity is an unbiased estimate of the underlying scattered intensity
Cite this review
Pith. "Pith review of Guided progressive reconstructive imaging: a new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography." pith.science (2026). https://pith.science/paper/QWOZEKFC
@misc{pith2026251217561,
author = {Pith},
title = {Pith review of: Guided progressive reconstructive imaging: a new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography},
year = {2026},
howpublished = {\url{https://pith.science/paper/QWOZEKFC}},
note = {Machine review of arXiv:2512.17561}
}
read the original abstract
By profiting from recent developments in detector technologies, making it possible to access a stream of detection events with few-ns time resolutions, a new ptychographic workflow is established. This methodological framework, referred to as guided progressive reconstructive imaging, relies on a quantization-based description of the acquired intensity, through an elementary derivation. Established direct phase retrieval solutions, such as the Wigner distribution deconvolution approach, can then be adapted to a continuous treatment of received counts, with no need for a dense data representation. Consequently, the result is obtained in the form of a progressively improving estimate, while providing immediate user feedback thanks to a processing speed high enough to surpass the acquisition bandwidth. This fast measurement is enabled by the cumulative usage of a pre-calculated library of kernel-limited functions, accumulating count-wise contributions as a function of the triggered detector pixel. Hence, the reconstruction offers the same advantages of direct phase retrieval methods, in particular a high dose-efficiency and the absence of complex convergence dynamics, with much less stringent restrictions on the field of view than is typical in current alternatives. Its implementation is also significantly more straightforward and flexible. Overall, this work constitutes a major evolution in the state-of-the-art, facilitating repeatable and low-dose experiments with high accessibility, and being applicable to electron-based imaging, X-ray diffraction and optical microscopy.
Figures
Figures from the paper (2 more)
Reference graph
Works this paper leans on
-
[33]
A. Annys, H. L. L. Robert, S. Gholam, J. Ha- dermann, J. Verbeeck, Removing constraints of 4D-STEM with a framework for event- driven acquisition and processing, Ultrami- croscopy 277 (2025) 114206.arXiv:2505.06602, doi:10.1016/j.ultramic.2025.114206. URLhttp://arxiv.org/abs/2505.06602https: //linkinghub.elsevier.com/retrieve/pii/ S0304399125001044
arXiv 2025
-
[100]
H. L. Lalandec Robert, J. Verbeeck, METHOD AND SYSTEM FOR RECONSTRUCTION OF AN IMAGE FROM ELECTRON DIFFRACTION DATA, International application published under the patent cooperation treaty (PCT), with number WO 2025/124784 A1 (2025)
2025
-
[1]
J. Rodenburg, A. Maiden, Ptychography, in: Springer Handbooks, Springer, 2019, pp. 819–904. doi:10.1007/978-3-030-00069-1_17. URLhttp://link.springer.com/10.1007/ 978-3-030-00069-1_17
-
[2]
R. Wang, Q. Zhao, L. Loetgering, F. Allars, Z. Hong, T. J. Pennycook, R. Horstmeyer, J. Ro- denburg, A. Maiden, G. Zheng, Ptychography at all wavelengths, Nature Reviews Methods Primers 5 (1) (2025) 68.doi:10.1038/s43586-025-00438-3. URLhttps://www.nature.com/articles/ s43586-025-00438-3
-
[3]
Hoppe, Beugung im inhomogenen Primärstrahlwellenfeld
W. Hoppe, Beugung im inhomogenen Primärstrahlwellenfeld. I. Prinzip einer Phasenmes- sung von Elektronenbeungungsinterferenzen, Acta Crystallographica Section A 25 (4) (1969) 495–501. doi:10.1107/S0567739469001045. URLhttps://scripts.iucr.org/cgi-bin/ paper?S0567739469001045
-
[4]
W. Hoppe, G. Strube, Beugung in inhomoge- nen Primärstrahlenwellenfeld. II. Lichtoptische Analogieversuche zur Phasenmessung von Gitterin- terferenzen, Acta Crystallographica Section A 25 (4) (1969) 502–507.doi:10.1107/S0567739469001057. URLhttps://scripts.iucr.org/cgi-bin/ paper?S0567739469001057
-
[5]
Hoppe, Beugung im inhomogenen Primärstrahlwellenfeld
W. Hoppe, Beugung im inhomogenen Primärstrahlwellenfeld. III. Amplituden- und Phasenbestimmung bei unperiodischen Objekten, Acta Crystallographica Section A 25 (4) (1969) 508–514.doi:10.1107/S0567739469001069. URLhttps://scripts.iucr.org/cgi-bin/ paper?S0567739469001069
-
[6]
J. Miao, Computational microscopy with coherent diffractive imaging and ptychog- raphy, Nature 637 (8045) (2025) 281–295. doi:10.1038/s41586-024-08278-z. URLhttp://dx.doi.org/10.1038/ s41586-024-08278-zhttps://www.nature.com/ articles/s41586-024-08278-z
Show all 166 references
-
[8]
H. M. Faulkner, J. M. Rodenburg, Movable aper- ture lensless transmission microscopy: A novel phase retrieval algorithm, Physical Review Letters 93 (2) (2004)2–5.doi:10.1103/PhysRevLett.93.023903
2004 doi
-
[9]
J. M. Rodenburg, H. M. Faulkner, A phase retrieval algorithm for shifting illumination, Applied Physics Letters 85 (20) (2004) 4795–4797.doi:10.1063/1. 1823034
2004 doi
-
[10]
Thibault, M
P. Thibault, M. Dierolf, A. Menzel, O. Bunk, C. David, F. Pfeiffer, High-resolution scanning X- ray diffraction microscopy, Science 321 (5887) (2008) 379–382.doi:10.1126/science.1158573
2008 doi
-
[11]
Guizar-Sicairos, J
M. Guizar-Sicairos, J. R. Fienup, Phase retrieval with transverse translation diversity: a nonlinear op- timization approach, Optics Express 16 (10) (2008) 7264.doi:10.1364/oe.16.007264
2008 doi
-
[12]
Müller, A
K. Müller, A. Rosenauer, M. Schowalter, J. Zweck, R. Fritz, K. Volz, Strain Measure- ment in Semiconductor Heterostructures by Scanning Transmission Electron Microscopy, Mi- croscopy and Microanalysis 18 (5) (2012) 995–1009. doi:10.1017/S1431927612001274. URLhttp://dx.doi.org/...
2012 doi
-
[13]
McMullan, D
G. McMullan, D. Cattermole, S. Chen, R. Hen- derson, X. Llopart, C. Summerfield, L. Tlustos, A. Faruqi, Electron imaging with Medipix2 hybrid pixel detector, Ultramicroscopy 107 (4-5) (2007) 401–413.doi:10.1016/j.ultramic.2006.10.005. URLhttps://linkinghub.elsevier.com/ retrie...
2007 doi
-
[14]
Ballabriga, M
R. Ballabriga, M. Campbell, E. Heijne, X. Llopart, L. Tlustos, W. Wong, Medipix3: A 64k pixel detector readout chip working in single pho- ton counting mode with improved spectrometric performance, Nuclear Instruments and Meth- ods in Physics Research Section A: Accelera- tors...
2011 doi
-
[15]
Plackett, I
R. Plackett, I. Horswell, E. N. Gimenez, J. Mar- chal, D. Omar, N. Tartoni, Merlin: a fast 15 versatile readout system for Medipix3, Jour- nal of Instrumentation 8 (1) (2013) C01038. doi:10.1088/1748-0221/8/01/C01038. URLhttp://iopscience.iop.org/article/10. 1088/1748-0221/8/0...
2013 doi
-
[16]
H. Ryll, M. Simson, R. Hartmann, P. Holl, M. Huth, S. Ihle, Y. Kondo, P. Kotula, A. Liebel, K. Müller- Caspary, A. Rosenauer, R. Sagawa, J. Schmidt, H. Soltau, L. Strüder, A pnCCD-based, fast direct single electron imaging camera for TEM and STEM, J. Instrum. 11 (04) (2016) P0...
2016 doi
-
[17]
M. W. Tate, P. Purohit, D. Chamberlain, K. X. Nguyen, R. Hovden, C. S. Chang, P. Deb, E. Turgut, J.T.Heron, D.G.Schlom, D.C.Ralph, G.D.Fuchs, K. S. Shanks, H. T. Philipp, D. A. Muller, S. M. Gruner, High Dynamic Range Pixel Array Detec- tor for Scanning Transmission Electron M...
2016 arXiv
-
[18]
H. T. Philipp, M. W. Tate, K. S. Shanks, L. Mele, M. Peemen, P. Dona, R. Hartong, G. van Veen, Y.-T. Shao, Z. Chen, J. Thom-Levy, D. A. Muller, S. M. Gruner, Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy, Microscopy and Microanal- y...
2022 arXiv
-
[19]
Zambon, S
P. Zambon, S. Bottinelli, R. Schnyder, D. Musarra, D. Boye, A. Dudina, N. Lehmann, S. De Carlo, M. Rissi, C. Schulze-Briese, M. Meffert, M. Cam- panini, R. Erni, L. Piazza, KITE: High frame rate, high count rate pixelated electron counting ASIC for 4D STEM applications featuri...
2022
-
[20]
Ercius, I
P. Ercius, I. J. Johnson, P. Pelz, B. H. Savitzky, L. Hughes, H. G. Brown, S. E. Zeltmann, S.-L. Hsu, C. C. S. Pedroso, B. E. Cohen, R. Ramesh, D. Paul, J. M. Joseph, T. Stezelberger, C. Czarnik, M. Lent, E. Fong, J. Ciston, M. C. Scott, C. Ophus, A. M. Minor, P. Denes, The 4D...
2024 arXiv
-
[21]
H. Yang, L. Jones, H. Ryll, M. Simson, H. Soltau, Y. Kondo, R. Sagawa, H. Banba, I. MacLaren, P. D. Nellist, 4D STEM: High efficiency phase contrast imaging using a fast pixelated detector, J. Phys.: Conf. Ser. 644 (1) (2015) 12032.doi:10.1088/ 1742-6596/644/1/012032. URLhttp:...
2015
-
[22]
Müller-Caspary, F
K. Müller-Caspary, F. F. Krause, F. Winkler, A. Béché, J. Verbeeck, S. Van Aert, A. Rosenauer, S. VanAert, A. Rosenauer, Comparison of first moment STEM with conventional differential phase contrast and the dependence on electron dose, Ultramicroscopy accepted (August 2018) (2...
2018 doi
-
[23]
Strauch, D
A. Strauch, D. Weber, A. Clausen, A. Lesnichaia, A. Bangun, B. März, F. J. Lyu, Q. Chen, A. Rosenauer, R. Dunin-Borkowski, K. Müller- Caspary, Live Processing of Momentum-Resolved STEM Data for First Moment Imaging and Pty- chography, Microscopy and Microanalysis 27 (5) (2021)...
2021 arXiv
-
[24]
C.-P. Yu, T. Friedrich, D. Jannis, S. Van Aert, J. Verbeeck, Real-Time Integration Center of Mass (riCOM) Reconstruction for 4D STEM, Microscopy and Microanalysis 28 (5) (2022) 1526–1537.arXiv:2112.04442, doi:10.1017/S1431927622000617. URLhttps://academic.oup.com/mam/article/ ...
2022 arXiv
-
[25]
Bangun, P
A. Bangun, P. F. Baumeister, A. Clausen, D. Weber, R. E. Dunin-Borkowski, Wigner Distribution De- convolution Adaptation for Live Ptychography Re- construction, Microscopy and Microanalysis 29 (3) (2023) 994–1008.arXiv:2212.01309,doi:10. 1093/micmic/ozad021. URLhttps://doi.org...
2023 arXiv
-
[26]
Weber, S
D. Weber, S. Ehrig, A. Schropp, A. Clausen, S. Achilles, N. Hoffmann, M. Bussmann, R. E. Dunin-Borkowski, C. G. Schroer, Live Iterative Ptychography, Microscopy and Microanalysis 30 (1) (2024) 103–117.arXiv:2308.10674, 16 doi:10.1093/mam/ozae004. URLhttp://arxiv.org/abs/2308.1...
2024 arXiv
-
[27]
Poikela, J
T. Poikela, J. Plosila, T. Westerlund, M. Campbell, M. D. Gaspari, X. Llopart, V. Gromov, R. Kluit, M. V. Beuzekom, F. Zappon, V. Zivkovic, C. Brez- ina, K. Desch, Y. Fu, A. Kruth, Timepix3: a 65K channel hybrid pixel readout chip with simultane- ous ToA/ToT and sparse readout...
2014 doi
-
[28]
Frojdh, M
E. Frojdh, M. Campbell, M. D. Gaspari, S. Kulis, X. Llopart, T. Poikela, L. Tlustos, Timepix3: first measurements and characterization of a hybrid-pixel detector working in event driven mode, Journal of Instrumentation 10 (01) (2015) C01039–C01039. doi:10.1088/1748-0221/10/01/...
2015 doi
-
[29]
Llopart, J
X. Llopart, J. Alozy, R. Ballabriga, M. Campbell, R. Casanova, V. Gromov, E. Heijne, T. Poikela, E. Santin, V. Sriskaran, L. Tlustos, A. Vitkovskiy, Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning, Journal...
2022 doi
-
[30]
Y. Auad, J. Baaboura, J. D. Blazit, M. Tencé, O. Stéphan, M. Kociak, L. H. Tizei, Time calibration studies for the Timepix3 hybrid pixel detector in electron microscopy, Ultrami- croscopy 257 (November 2023) (2024) 113889. doi:10.1016/j.ultramic.2023.113889. URLhttps://doi.org...
2023
-
[31]
Kuttruff, J
J. Kuttruff, J. Holder, Y. Meng, P. Baum, Real-time electron clustering in an event- driven hybrid pixel detector, Ultrami- croscopy 255 (September 2023) (2024) 113864. doi:10.1016/j.ultramic.2023.113864. URLhttps://doi.org/10.1016/j.ultramic. 2023.113864
2023
-
[32]
Jannis, C
D. Jannis, C. Hofer, C. Gao, X. Xie, A. Béché, T. Pennycook, J. Verbeeck, Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications, Ultramicroscopy 233 (Oc- tober 2021) (2022) 113423.arXiv:2...
2021 arXiv
-
[34]
Pfeiffer, X-ray ptychography, Nature Pho- tonics 12 (1) (2018) 9–17.doi:10.1038/ s41566-017-0072-5
F. Pfeiffer, X-ray ptychography, Nature Pho- tonics 12 (1) (2018) 9–17.doi:10.1038/ s41566-017-0072-5
2018
-
[35]
Egerton, Radiation damage to organic and inorganic specimens in the TEM, Mi- cron 119 (January) (2019) 72–87.doi: 10.1016/j.micron.2019.01.005
R. Egerton, Radiation damage to organic and inorganic specimens in the TEM, Mi- cron 119 (January) (2019) 72–87.doi: 10.1016/j.micron.2019.01.005. URLhttps://doi.org/10.1016/j.micron.2019. 01.005https://linkinghub.elsevier.com/ retrieve/pii/S0968432818304359
2019 doi
-
[36]
T. J. Pennycook, G. T. Martinez, P. D. Nel- list, J. C. Meyer, High dose efficiency atomic resolution imaging via electron ptychography, Ul- tramicroscopy 196 (October 2018) (2019) 131–135. doi:10.1016/j.ultramic.2018.10.005. URLhttps://doi.org/10.1016/j.ultramic. 2018.10.005
2018 doi
-
[37]
C. M. O’Leary, C. S. Allen, C. Huang, J. S. Kim, E. Liberti, P. D. Nellist, A. I. Kirkland, Phase reconstruction using fast binary 4D STEM data, Applied Physics Letters 116 (12) (2020) 124101. doi:10.1063/1.5143213. URLhttps://pubs.aip.org/apl/ article/116/12/124101/570971/ Ph...
2020 doi
-
[38]
C. M. O’Leary, G. T. Martinez, E. Liberti, M. J. Humphry, A. I. Kirkland, P. D. Nellist, Contrast transfer and noise considerations in focused-probe electron ptychography, Ultrami- croscopy 221 (December 2020) (2021) 113189. doi:10.1016/j.ultramic.2020.113189. URLhttps://doi.o...
2020
-
[39]
Jílek, T
Z. Jílek, T. Radlička, V. Krzyžánek, Simulation Study of Low-Dose 4D-STEM Phase Contrast Tech- niques at the Nanoscale in SEM, Nanomaterials 17 15 (1) (2025) 70.doi:10.3390/nano15010070. URLhttps://www.mdpi.com/2079-4991/15/1/70
2025 doi
-
[40]
H. L. Lalandec Robert, M. L. Leidl, K. Müller- Caspary, J. Verbeeck, Benchmarking analytical electron ptychography methods for the low-dose imaging of beam-sensitive materials, The European Physical Journal Applied Physics 100 (2025) 20. arXiv:2501.08874,doi:10.1051/epjap/2025...
2025 arXiv
-
[41]
Dearg, N
M. Dearg, N. Michaelides, J. Gilbert, Z. Ding, Z. Aslam, D. Hopkinson, C. Allen, L. Clark, Stabil- ity of electron ptychography at low electron dose, Journal of Microscopy (February) (2025) 1–10. doi:10.1111/jmi.70011. URLhttps://onlinelibrary.wiley.com/doi/ 10.1111/jmi.70011
2025 doi
-
[42]
H. Yang, R. N. Rutte, L. Jones, M. Simson, R. Sagawa, H. Ryll, M. Huth, T. J. Pennycook, M. L. H. Green, H. Soltau, Y. Kondo, B. G. Davis, P. D. Nellist, Simultaneous atomic-resolution elec- tron ptychography and Z-contrast imaging of light and heavy elements in complex nanost...
2016 doi
-
[44]
P. Wang, F. Zhang, S. Gao, M. Zhang, A. I. Kirkland, Electron ptychographic diffractive imag- ing of boron atoms in LaB 6 crystals, Scien- tific Reports 7 (1) (2017) 1–8.doi:10.1038/ s41598-017-02778-x
2017
-
[46]
M. L. Leidl, C. Sachse, K. Müller-Caspary, Dy- namical scattering in ice-embedded proteins in conventional and scanning transmission elec- tron microscopy, IUCrJ 10 (4) (2023) 867–876. doi:10.1107/S2052252523004505. URLhttps://scripts.iucr.org/cgi-bin/ paper?S2052252523004505
2023 doi
-
[47]
J. G. Lozano, G. T. Martinez, L. Jin, P. D. Nel- list, P. G. Bruce, Low-Dose Aberration-Free Imag- ing of Li-Rich Cathode Materials at Various States of Charge Using Electron Ptychography, Nano Let- ters 18 (11) (2018) 6850–6855.doi:10.1021/acs. nanolett.8b02718
2018 doi
-
[48]
W. Song, M. A. Pérez-Osorio, J.-J. Marie, E. Lib- erti, X. Luo, C. O’Leary, R. A. House, P. G. Bruce, P. D. Nellist, Direct imaging of oxygen shifts associated with the oxygen redox of Li-rich layered oxides, Joule 6 (5) (2022) 1049–1065. doi:10.1016/j.joule.2022.04.008. URLht...
2022 doi
-
[49]
W. Song, M. A. Pérez-Osorio, J. Chen, Z. Ding, J.-J. Marie, M. Juelsholt, R. A. House, P. G. Bruce, P. D. Nellist, Visualization of Tetrahedral Li in the Al- kali Layers of Li-Rich Layered Metal Oxides, Journal of the American Chemical Society 146 (34) (2024) 23814–23824.doi:1...
2024 doi
-
[50]
H. Sha, J. Cui, J. Li, Y. Zhang, W. Yang, Y. Li, R. Yu, Ptychographic measurements of varying size and shape along zeolite channels, Science Advances 9 (11) (2023) 1–8.doi:10.1126/sciadv.adf1151. URLhttps://doi.org/10.1126/sciadv.adf1151
2023 doi
-
[51]
Zhang, G
H. Zhang, G. Li, J. Zhang, D. Zhang, Z. Chen, X. Liu, P. Guo, Y. Zhu, C. Chen, L. Liu, X. Guo, Y. Han, Three-dimensional inhomogeneity of zeolite structure and composition revealed by electron ptychography, Science 380 (6645) (2023) 633–638. doi:10.1126/science.adg3183. URLhtt...
2023 doi
-
[52]
Z. Dong, E. Zhang, Y. Jiang, Q. Zhang, A. May- oral, H. Jiang, Y. Ma, Atomic-Level Imaging of Zeo- lite Local Structures Using Electron Ptychography, Journal of the American Chemical Society 145 (12) (2023) 6628–6632.doi:10.1021/jacs.2c12673. URLhttps://pubs.acs.org/doi/10.102...
2023 doi
-
[53]
Mitsuishi, K
K. Mitsuishi, K. Nakazawa, R. Sagawa, M. Shimizu, H. Matsumoto, H. Shima, T. Takewaki, Direct observation of Cu in high-silica chabazite zeolite by electron ptychography using Wigner distribution deconvolution, Scientific Reports 13 (1) (2023) 316. doi:10.1038/s41598-023-27452...
2023 doi
-
[54]
B. Hao, Z. Ding, X. Tao, P. D. Nellist, H. E. Assender, Atomic-scale imaging of polyvinyl 18 alcohol crystallinity using electron ptychog- raphy, Polymer 284 (August) (2023) 126305. doi:10.1016/j.polymer.2023.126305. URLhttps://doi.org/10.1016/j.polymer. 2023.126305https://lin...
2023
-
[55]
Chen, T.-C
Y. Chen, T.-C. Chou, C.-H. Fang, C.-Y. Lu, C.-N. Hsiao, W.-T. Hsu, C.-C. Chen, Direct observation of single-atom defects in monolayer two-dimensional materials by using electron ptychography at 200 kV acceleration voltage, Scientific Reports 14 (1) (2024) 277.doi:10.1038/s4159...
2024 doi
-
[56]
L. Loh, S. Ning, D. Kieczka, Y. Chen, J. Yang, Z. Wang, S. J. Pennycook, G. Eda, A. L. Shluger, M. Bosman, Electron Ptychography for Atom- by-Atom Quantification of 1D Defect Complexes in Monolayer MoS 2, ACS Nano (feb 2025). doi:10.1021/acsnano.4c14988. URLhttps://pubs.acs.or...
2025 doi
-
[57]
Hofer, J
C. Hofer, J. Madsen, T. Susi, T. J. Penny- cook, Detecting charge transfer at defects in 2D materials with electron ptychography, Journal of Microscopy (December 2024) (2025) 1–11. arXiv:2301.04469,doi:10.1111/jmi.13404. URLhttp://arxiv.org/abs/2301.04469https: //onlinelibrary...
2024 arXiv
-
[58]
G. Li, M. Xu, W.-q. Tang, Y. Liu, C. Chen, D. Zhang, L. Liu, S. Ning, H. Zhang, Z.-y. Gu, Z. Lai, D. A. Muller, Y. Han, Atomically resolved imaging of radiation-sensitive metal- organic frameworks via electron ptychography, Nature Communications 16 (1) (2025) 914. doi:10.1038/...
2025 doi
-
[59]
Scheid, Y
A. Scheid, Y. Wang, M. Jung, T. Heil, D. Moia, J. Maier, P. A. van Aken, Electron Ptychographic Phase Imaging of Beam-sensitive All-inorganic Halide Perovskites Using Four-dimensional Scan- ning Transmission Electron Microscopy, Mi- croscopy and Microanalysis 29 (3) (2023) 869...
2023 doi
-
[60]
B. Yuan, Z. Wang, S. Zhang, C. Hofer, C. Gao, T. Chennit, H. Shi, X. Wu, Y. Han, L. Dou, Y. Yu, T. J. Pennycook, Atomically resolved edges and defects in lead halide per- ovskites, Nature 647 (8089) (2025) 364–368. doi:10.1038/s41586-025-09693-6. URLhttps://www.nature.com/arti...
2025 doi
-
[61]
L. Zhou, J. Song, J. S. Kim, X. Pei, C. Huang, M. Boyce, L. Mendonça, D. Clare, A. Siebert, C. S. Allen, E. Liberti, D. Stuart, X. Pan, P. D. Nellist, P. Zhang, A. I. Kirkland, P. Wang, Low-dose phase retrieval of biological specimens using cryo-electron ptychography, Nature C...
2020 doi
-
[62]
X. Pei, L. Zhou, C. Huang, M. Boyce, J. S. Kim, E. Liberti, Y. Hu, T. Sasaki, P. D. Nellist, P. Zhang, D. I. Stuart, A. I. Kirkland, P. Wang, Cryogenic electron ptychographic single particle analysis with wide bandwidth information trans- fer, Nature Communications 14 (1) (202...
2023 doi
-
[63]
Küçükoğlu, I
B. Küçükoğlu, I. Mohammed, R. C. Guerrero- Ferreira, S. M. Ribet, G. Varnavides, M. L. Leidl, K. Lau, S. Nazarov, A. Myasnikov, M. Kube, J.Radecke, C.Sachse, K.Müller-Caspary, C.Ophus, H. Stahlberg, Low-dose cryo-electron ptychogra- phy of proteins at sub-nanometer resolution,...
2024 doi
-
[64]
Cheng, N
Y. Cheng, N. Grigorieff, P. A. Penczek, T. Walz, A Primer to Single-Particle Cryo- Electron Microscopy, Cell 161 (3) (2015) 438–449. doi:10.1016/j.cell.2015.03.050. URLhttp://dx.doi.org/10.1016/j.cell.2015. 03.050https://linkinghub.elsevier.com/ retrieve/pii/S0092867415003700
2015 doi
-
[65]
Nakane, A
T. Nakane, A. Kotecha, A. Sente, G. McMul- lan, S. Masiulis, P. M. G. E. Brown, I. T. Grigoras, L. Malinauskaite, T. Malinauskas, J. Miehling, T. Uchański, L. Yu, D. Karia, E. V. Pechnikova, E. de Jong, J. Keizer, M. Bischoff, J. McCormack, P. Tiemeijer, S. W. Hardwick, D. Y. ...
2020 doi
-
[66]
Thibault, M
P. Thibault, M. Guizar-Sicairos, Maximum- likelihood refinement for coherent diffractive imaging, New Journal of Physics 14 (2012) 1–20. doi:10.1088/1367-2630/14/6/063004
2012 doi
-
[67]
Odstrčil, A
M. Odstrčil, A. Menzel, M. Guizar-Sicairos, Itera- tive least-squares solver for generalized maximum- likelihood ptychography, Optics Express 26 (3) (2018) 3108.doi:10.1364/oe.26.003108
2018 doi
-
[68]
Schloz, T
M. Schloz, T. C. Pekin, Z. Chen, W. Van den Broek, D. A. Muller, C. T. Koch, Overcoming in- formation reduced data and experimentally uncer- tain parameters in ptychography with regularized optimization, Optics Express 28 (19) (2020) 28306. arXiv:2005.01530,doi:10.1364/oe.396925
2020 arXiv
-
[69]
Z. Chen, Y. Jiang, Y.-T. T. Shao, M. E. Holtz, M. Odstrčil, M. Guizar-Sicairos, I. Hanke, S. Gan- schow, D. G. Schlom, D. A. Muller, Electron pty- chography achieves atomic-resolution limits set by lattice vibrations, Science 372 (6544) (2021) 826– 831.arXiv:2101.00465,doi:10....
2021 arXiv
-
[70]
H. Sha, J. Cui, R. Yu, Deep sub-angstrom resolution imaging by electron ptychography with misorienta- tion correction, Science Advances 8 (19) (2022) 1–7. doi:10.1126/sciadv.abn2275. URLhttps://www.science.org/doi/10.1126/ sciadv.abn2275
2022 doi
-
[71]
Maiden, W
A. Maiden, W. Mei, P. Li, WASP: Weighted Average of Sequential Projections for ptychographic phase re- trieval, Optics Express 32 (12) (2024) 21327–21344. doi:10.1364/oe.516946
2024 doi
-
[72]
Marchesini, H
S. Marchesini, H. Krishnan, B. J. Daurer, D. A. Shapiro, T. Perciano, J. A. Sethian, F. R. Maia, SHARP: A distributed GPU-based ptychographic solver, Journal of Applied Crystallography 49 (4) (2016) 1245–1252.arXiv:1602.01448,doi:10. 1107/S1600576716008074
2016 arXiv
-
[73]
Wakonig, H
K. Wakonig, H. C. Stadler, M. Odstrcil, E. H. Tsai, A. DIaz, M. Holler, I. Usov, J. Raabe, A. Men- zel, M. Guizar-Sicairos, PtychoShelves, a versa- tile high-level framework for high-performance anal- ysis of ptychographic data, Journal of Applied Crystallography 53 (2020) 574...
2020
-
[74]
X. Yu, V. Nikitin, D. J. Ching, S. Aslan, D. Gürsoy, T. Biçer, Scalable and accurate multi-GPU-based image reconstruction of large-scale ptychography data, Scientific Re- ports 12 (1) (2022) 1–16.arXiv:2106.07575, doi:10.1038/s41598-022-09430-3. URLhttps://doi.org/10.1038/ s41...
2022 arXiv
-
[75]
X. Wang, A. Tsaris, D. Mukherjee, M. Wahib, P. Chen, M. Oxley, O. Ovchinnikova, J. Hin- kle, Image Gradient Decomposition for Parallel and Memory-Efficient Ptychographic Recon- struction, in: SC22: International Conference for High Performance Computing, Network- ing, Storage ...
2022 arXiv
-
[76]
Gilgenbach, J
C. Gilgenbach, J. M. LeBeau, phaser: An all-in- one package for (multislice) electron ptychography (2025) 34–38arXiv:2505.14372. URLhttp://arxiv.org/abs/2505.14372
2025 arXiv
-
[77]
C.-H. Lee, S. E. Zeltmann, D. Yoon, D. Ma, D. A. Muller, PtyRAD: A High-performance and Flexible Ptychographic Reconstruction Framework with Au- tomatic Differentiation (2016) (may 2025).arXiv: 2505.07814. URLhttp://arxiv.org/abs/2505.07814
2016 arXiv
-
[78]
Skoupy, E
R. Skoupy, E. Müller, T. J. Pennycook, M. Guizar- Sicairos, E. Fabbri, E. Poghosyan, Ptychoscopy: a user friendly experimental design tool for pty- chography, Scientific Reports 15 (1) (2025) 24959. doi:10.1038/s41598-025-09871-6. URLhttps://www.nature.com/articles/ s41598-025-09871-6
2025 doi
-
[79]
Mukherjee, K
D. Mukherjee, K. M. Roccapriore, A. Al-Najjar, A. Ghosh, J. D. Hinkle, A. R. Lupini, R. K. Vasudevan, S. V. Kalinin, O. S. Ovchinnikova, M. A. Ziatdinov, N. S. Rao, A Roadmap for Edge Computing Enabled Automated Multidimensional Transmission Electron Microscopy, Microscopy Tod...
2022 arXiv
-
[80]
S. S. Welborn, C. Harris, S. M. Ribet, G. Varna- vides, C. Ophus, B. Enders, P. Ercius, Streaming Large-Scale Microscopy Data to a Supercomputing Facility, Microscopy and Microanalysis (2024) 1– 9arXiv:2407.03215,doi:10.1093/mam/ozae109. URLhttp://arxiv.org/abs/2407.03215https...
2024 arXiv
-
[81]
Katkovnik, J
V. Katkovnik, J. Astola, Sparse ptychographical coherent diffractive imaging from noisy measure- ments, Journal of the Optical Society of America A 30 (3) (2013) 367.doi:10.1364/JOSAA.30.000367. URLhttps://opg.optica.org/abstract.cfm? URI=josaa-30-3-367
2013 doi
-
[82]
Chennit, S
T. Chennit, S. Li, H. L. Lalandec Robert, C. Hofer, N. J. Schrenker, L. Manna, S. Bals, T. J. Pen- nycook, J. Verbeeck, Investigating the conver- gence properties of iterative ptychography for atomic-resolution low-dose imaging, Ultrami- croscopy 278 (2025) 114245.arXiv:2507.0...
2025
-
[83]
Maiden, D
A. Maiden, D. Johnson, P. Li, Further improvements to the ptychographical iterative engine, Optica 4 (7) (2017) 736.doi:10.1364/optica.4.000736
2017 doi
-
[84]
Bangun, O
A. Bangun, O. Melnyk, B. Marz, B. Diederichs, A. Clausen, D. Weber, F. Filbir, K. Muller-Caspary, Inverse Multislice Ptychography by Layer-wise Op- timisation and Sparse Matrix Decomposition, IEEE Transactions on Computational Imaging 8 (2022) 1–16.arXiv:2205.03902,doi:10.1109...
2022 arXiv
-
[85]
M. L. Leidl, B. Diederichs, C. Sachse, K. Müller- Caspary, Influence of loss function and electron dose on ptychography of 2D materials using the Wirtinger flow, Micron 185 (July) (2024) 103688. doi:10.1016/j.micron.2024.103688. URLhttps://doi.org/10.1016/j.micron.2024. 103688...
2024
-
[86]
Müller, F
K. Müller, F. F. Krause, A. Béché, M. Schowal- ter, V. Galioit, S. Löffler, J. Verbeeck, J. Zweck, P. Schattschneider, A. Rosenauer, Atomic electric fields revealed by a quantum mechanical approach to electron picodiffraction, Nature Communications 5 (1) (2014) 5653.doi:10.103...
2014 doi
-
[87]
Lazić, E
I. Lazić, E. G. T. Bosch, S. Lazar, Phase contrast {STEM} for thin samples: Inte- grated differential phase contrast, Ultrami- croscopy 160 (2016) 265–280.doi:http: //doi.org/10.1016/j.ultramic.2015.10.011. URLhttp://www.sciencedirect.com/science/ article/pii/S0304399115300449
2016 doi
-
[88]
Yücelen, I
E. Yücelen, I. Lazic, E. G. T. Bosch, I. Lazić, E. G. T. Bosch, Phase contrast scanning trans- mission electron microscopy imaging of light and heavy atoms at the limit of contrast and resolution, Scientific Reports 8 (1) (2018) 1–10. doi:10.1038/s41598-018-20377-2. URLhttps:/...
2018 doi
-
[90]
J. M. Rodenburg, R. H. T. Bates, The the- ory of super-resolution electron microscopy via Wigner-distribution deconvolution, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences 339 (1655) (1992) 521–553.doi:10.1098/rsta.1992.0...
1992
-
[92]
P. Li, T. B. Edo, J. M. Rodenburg, Pty- chographic inversion via Wigner distribution deconvolution: Noise suppression and probe design, Ultramicroscopy 147 (2014) 106–113. doi:10.1016/j.ultramic.2014.07.004. URLhttp://dx.doi.org/10.1016/j.ultramic. 2014.07.004
2014 doi
-
[93]
Rodenburg, B
J. Rodenburg, B. McCallum, P. Nellist, Experi- mental tests on double-resolution coherent imaging via STEM, Ultramicroscopy 48 (3) (1993) 304–314. doi:10.1016/0304-3991(93)90105-7. URLhttps://linkinghub.elsevier.com/ retrieve/pii/0304399193901057
1993
-
[94]
T. J. Pennycook, A. R. Lupini, H. Yang, M. F. Murfitt, L. Jones, P. D. Nellist, Efficient phase contrast imaging in STEM using a pixelated detec- tor. Part 1: Experimental demonstration at atomic resolution, Ultramicroscopy 151 (0) (2015) 160–167. doi:10.1016/j.ultramic.2014.0...
2015 doi
-
[95]
H. Yang, T. J. Pennycook, P. D. Nellist, Efficient phase contrast imaging in STEM using a pixelated detector. Part II: Optimisation of imaging con- ditions, Ultramicroscopy 151 (0) (2015) 232–239. 21 doi:10.1016/j.ultramic.2014.10.013. URLhttp://www.sciencedirect.com/science/ ...
2015 doi
-
[96]
H. Yang, P. Ercius, P. D. Nellist, C. Ophus, Enhanced phase contrast transfer using pty- chography combined with a pre-specimen phase plate in a scanning transmission electron mi- croscope, Ultramicroscopy 171 (2016) 117–125. doi:10.1016/j.ultramic.2016.09.002. URLhttp://dx.do...
2016 doi
-
[97]
H. Guo, E. Franken, Y. Deng, S. Benlekbir, G. Singla Lezcano, B. Janssen, L. Yu, Z. A. Ripstein, Y. Z. Tan, J. L. Rubinstein, Electron- event representation data enable efficient cryoEM file storage with full preservation of spatial and temporal resolution, IUCrJ 7 (5) (2020) ...
2020 doi
-
[98]
Datta, K
A. Datta, K. F. Ng, D. Balakrishnan, M. Ding, S. W. Chee, Y. Ban, J. Shi, N. D. Loh, A data reduction and compression description for high throughput time-resolved electron microscopy, Nature Communications 12 (1) (2021) 664. doi:10.1038/s41467-020-20694-z. URLhttp://dx.doi.or...
2021 doi
-
[99]
P. M. Pelz, I. Johnson, C. Ophus, P. Ercius, M. C. Scott, Real-Time Interactive 4D-STEM Phase- Contrast Imaging From Electron Event Representa- tion Data: Less computation with the right repre- sentation, IEEE Signal Processing Magazine 39 (1) (2022) 25–31.doi:10.1109/MSP.2021...
2022
-
[101]
F.Hüe, J.M.Rodenburg, A.M.Maiden, F.Sweeney, P. A. Midgley, Wave-front phase retrieval in trans- mission electron microscopy via ptychography, Phys- ical Review B - Condensed Matter and Materi- als Physics 82 (12) (2010) 1–4.doi:10.1103/ PhysRevB.82.121415
2010
-
[102]
J. Song, C. S. Allen, S. Gao, C. Huang, H. Sawada, X. Pan, J. Warner, P. Wang, A. I. Kirkland, Atomic Resolution Defocused Electron Ptychog- raphy at Low Dose with a Fast, Direct Electron Detector, Scientific Reports 9 (1) (2019) 3919. doi:10.1038/s41598-019-40413-z. URLhttp:/...
2019 doi
-
[103]
J. A. Mir, R. Clough, R. MacInnes, C. Gough, R. Plackett, I. Shipsey, H. Sawada, I. Ma- cLaren, R. Ballabriga, D. Maneuski, V. O’Shea, D. McGrouther, A. I. Kirkland, Characterisa- tion of the Medipix3 detector for 60 and 80 keV electrons, Ultramicroscopy 182 (2017) 44–53. doi:...
2017 doi
-
[104]
M. C. Cao, Y. Han, Z. Chen, Y. Jiang, K. X. Nguyen, E. Turgut, G. D. Fuchs, D. A. Muller, Theory and practice of electron diffraction from sin- gle atoms and extended objects using an EMPAD, Microscopy 67 (December 2017) (2018) i150–i161. doi:10.1093/jmicro/dfx123
2017 doi
-
[105]
Aharonov, D
Y. Aharonov, D. Bohm, Significance of Electromag- netic Potentials in the Quantum Theory, Phys. Rev. 115 (3) (1959) 485–491.doi:10.1103/PhysRev. 115.485
1959 doi
-
[106]
J. N. Cederquist, C. C. Wackerman, Phase- retrieval error: a lower bound, Journal of the Optical Society of America A 4 (9) (1987) 1788. doi:10.1364/JOSAA.4.001788. URLhttps://opg.optica.org/abstract.cfm? URI=josaa-4-9-1788
1987 doi
-
[107]
Luczka, M
J. Luczka, M. Niemiec, A master equation for quan- tum systems driven by Poisson white noise, Jour- nal of Physics A: Mathematical and General 24 (17) (1991) L1021–L1024.doi:10.1088/0305-4470/24/ 17/010. URLhttps://iopscience.iop.org/article/10. 1088/0305-4470/24/17/010
1991 doi
-
[108]
Drenth, A
A. Drenth, A. Huiser, H. Ferwerda, The Prob- lem of Phase Retrieval in Light and Electron Microscopy of Strong Objects, Optica Acta: Inter- national Journal of Optics 22 (7) (1975) 615–628. doi:10.1080/713819083. URLhttps://doi.org/10.1080/ 713819083https://www.tandfonline.com...
1975 doi
-
[109]
Godard, M
P. Godard, M. Allain, V. Chamard, J. Rodenburg, Noise models for low counting rate coherent diffrac- tion imaging, Optics Express 20 (23) (2012) 25914. doi:10.1364/OE.20.025914. URLhttps://opg.optica.org/abstract.cfm? URI=oe-20-23-25914
2012 doi
-
[110]
A. J. D’Alfonso, L. J. Allen, H. Sawada, A. I. Kirkland, Dose-dependent high-resolution electron 22 ptychography, Journal of Applied Physics 119 (5) (2016) 0–5.doi:10.1063/1.4941269. URLhttp://dx.doi.org/10.1063/ 1.4941269https://pubs.aip.org/ jap/article/119/5/054302/142480/ ...
2016 doi
-
[111]
Madsen, T
J. Madsen, T. Susi, The abTEM code: trans- mission electron microscopy from first prin- ciples, Open Research Europe 1 (2021) 24. doi:10.12688/openreseurope.13015.2. URLhttps://open-research-europe.ec. europa.eu/articles/1-24/v2
2021 doi
-
[112]
J. P. van Schayck, E. van Genderen, E. Maddox, L. Roussel, H. Boulanger, E. Fröjdh, J.-P. Abra- hams, P. J. Peters, R. B. Ravelli, Sub-pixel electron detection using a convolutional neural network, Ultramicroscopy 218 (February) (2020) 113091. doi:10.1016/j.ultramic.2020.11309...
2020
-
[113]
T. Seki, Y. Ikuhara, N. Shibata, Theoret- ical framework of statistical noise in scan- ning transmission electron microscopy, Ul- tramicroscopy 193 (June) (2018) 118–125. doi:10.1016/j.ultramic.2018.06.014. URLhttps://doi.org/10.1016/j.ultramic. 2018.06.014http://www.sciencedi...
2018 doi
-
[114]
L. Bian, J. Suo, J. Chung, X. Ou, C. Yang, F. Chen, Q. Dai, Fourier ptychographic reconstruc- tion using Poisson maximum likelihood and trun- cated Wirtinger gradient, Scientific Reports 6 (June) (2016) 1–10.arXiv:1603.04746,doi:10.1038/ srep27384
2016 arXiv
-
[115]
Seifert, Y
J. Seifert, Y. Shao, R. van Dam, D. Bouchet, T. van Leeuwen, A. P. Mosk, Maximum-likelihood estima- tion in ptychography in the presence of Poisson- Gaussian noise statistics (2023) 1–11arXiv:2308. 02436,doi:10.1364/OL.502344. URLhttp://arxiv.org/abs/2308.02436http:// dx.doi.o...
2023 arXiv
-
[116]
Fujiwara, Relativistic Dynamical Theory of Electron Diffraction, Journal of the Physi- cal Society of Japan 16 (11) (1961) 2226–2238
K. Fujiwara, Relativistic Dynamical Theory of Electron Diffraction, Journal of the Physi- cal Society of Japan 16 (11) (1961) 2226–2238. doi:10.1143/JPSJ.16.2226. URLhttps://journals.jps.jp/doi/10.1143/ JPSJ.16.2226
1961 doi
-
[117]
J. M. Cowley, I. Sumio, S. Iijima, Electron Micro- scope Image Contrast for Thin Crystal, Zeitschrift für Naturforschung A 27 (3) (1972) 445–451. doi:10.1515/zna-1972-0312. URLhttps://www.degruyter.com/document/ doi/10.1515/zna-1972-0312/htmlhttps: //www.degruyter.com/view/j/z...
1972 doi
-
[118]
Z. Chen, E. Turgut, Y. Jiang, K. X. Nguyen, M. J. Stolt, S. Jin, D. C. Ralph, G. D. Fuchs, D. A. Muller, Lorentz electron ptychography for imaging magnetic textures beyond the diffraction limit, Na- tureNanotechnology17(11)(2022)1165–1170.doi: 10.1038/s41565-022-01224-y
2022 doi
-
[119]
J. Cui, H. Sha, W. Yang, R. Yu, Antiferro- magnetic imaging via ptychographic phase retrieval, Science Bulletin (xxxx) (dec 2023). doi:10.1016/j.scib.2023.12.044. URLhttps://doi.org/10.1016/j.scib.2023. 12.044https://linkinghub.elsevier.com/ retrieve/pii/S2095927323009167
2023 doi
-
[120]
Robert, I
H. Robert, I. Lobato, F. Lyu, Q. Chen, S. Van Aert, D. Van Dyck, K. Müller-Caspary, Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning trans- mission electron microscopy at atomic resolution, Ultramicroscopy 233 (October 2021...
2021
-
[121]
O. Bunk, M. Dierolf, S. Kynde, I. Johnson, O. Marti, F. Pfeiffer, Influence of the overlap parameter on the convergence of the ptychographical iterative engine, Ultramicroscopy 108 (5) (2008) 481–487. doi:10.1016/j.ultramic.2007.08.003. URLhttps://linkinghub.elsevier.com/ retr...
2008 doi
-
[122]
C. J. Humphreys, P. B. Hirsch, Absorption param- eters in electron diffraction theory, Philosophical Magazine 18 (151) (1968) 115–122.doi:10.1080/ 14786436808227313
1968
-
[123]
Grieb, P
A.Beyer, F.F.Krause, H.L.Robert, S.Firoozabadi, T. Grieb, P. Kükelhan, D. Heimes, M. Schowalter, K. Müller-Caspary, A. Rosenauer, K. Volz, Influ- ence of plasmon excitations on atomic-resolution quantitative 4D scanning transmission electron microscopy, Scientific Reports 10 (...
2020 doi
-
[124]
Barthel, L
J. Barthel, L. J. Allen, Role of ionization in imaging and spectroscopy utilizing fast electrons that have 23 excited phonons, Physical Review B 104 (10) (2021) 1–13.doi:10.1103/PhysRevB.104.104108
2021 doi
-
[125]
H. L. Robert, B. Diederichs, K. Müller-Caspary, Contribution of multiple plasmon scattering in low-angle electron diffraction investigated by energy-filtered atomically resolved 4D-STEM, Applied Physics Letters 121 (21) (2022) 213502. doi:10.1063/5.0129692. URLhttps://aip.scit...
2022 doi
-
[126]
Van Dyck, Is the frozen phonon model adequate to describe inelastic phonon scattering?, Ultrami- croscopy 109 (6) (2009) 677–682.doi:10.1016/j
D. Van Dyck, Is the frozen phonon model adequate to describe inelastic phonon scattering?, Ultrami- croscopy 109 (6) (2009) 677–682.doi:10.1016/j. ultramic.2009.01.001
2009 doi
-
[127]
Van Dyck, Persistent misconceptions about incoherence in electron microscopy, Ultramicroscopy 111 (7) (2011) 894–900
D. Van Dyck, Persistent misconceptions about incoherence in electron microscopy, Ultramicroscopy 111 (7) (2011) 894–900. doi:10.1016/j.ultramic.2011.01.007. URLhttp://www.sciencedirect.com/science/ article/pii/S0304399111000222https: //linkinghub.elsevier.com/retrieve/pii/ S03...
2011 doi
-
[128]
R. S. Ruskin, Z. Yu, N. Grigorieff, Quanti- tative characterization of electron detectors for transmission electron microscopy, Journal of Structural Biology 184 (3) (2013) 385–393. doi:10.1016/j.jsb.2013.10.016. URLhttp://dx.doi.org/10.1016/j.jsb.2013. 10.016https://linkinghu...
2013 doi
-
[129]
Paszke, S
A. Paszke, S. Gross, F. Massa, A. Lerer, J. Brad- bury, G. Chanan, T. Killeen, Z. Lin, N. Gimelshein, L. Antiga, A. Desmaison, A. Kopf, E. Yang, Z. DeVito, M. Raison, A. Tejani, S. Chilamkurthy, B.Steiner, L.Fang, J.Bai, S.Chintala, PyTorch: An Imperative Style, High-Performan...
2019
-
[130]
G. C. Capitani, P. Oleynikov, S. Hovmöller, M. Mellini, A practical method to detect and cor- rect for lens distortion in the TEM, Ultramicroscopy 106 (2) (2006) 66–74.doi:10.1016/j.ultramic. 2005.06.003
2006 doi
-
[131]
Z. Li, J. Biskupek, U. Kaiser, H. Rose, Integrated Differential Phase Contrast (IDPC)-STEM Utilizing a Multi-Sector Detector for Imaging Thick Samples, Microscopy and Microanalysis 28 (3) (2022) 611– 621.doi:10.1017/S1431927622000289
2022 doi
-
[132]
Grieb, F
T. Grieb, F. F. Krause, T. Mehrtens, C. Mahr, B. Gerken, M. Schowalter, B. Freitag, A. Rose- nauer, GaN atomic electric fields from a segmented STEM detector: Experiment and simulation, Journal of Microscopy (January) (2024) 1–7. doi:10.1111/jmi.13276. URLhttps://onlinelibrary...
2024 doi
-
[133]
Pöllath, F
S. Pöllath, F. Schwarzhuber, J. Zweck, The differential phase contrast uncertainty relation: Connection between electron dose and field resolu- tion, Ultramicroscopy 228 (March) (2021) 113342. doi:10.1016/j.ultramic.2021.113342. URLhttps://doi.org/10.1016/j.ultramic. 2021.113342
2021
-
[134]
Lorenzen, B
T. Lorenzen, B. März, T. Xue, A. Beyer, K. Volz, T. Bein, K. Müller-Caspary, Imaging built-in elec- tric fields and light matter by Fourier-precession TEM, Scientific Reports 14 (1) (2024) 1320. doi:10.1038/s41598-024-51423-x. URLhttps://doi.org/10.1038/ s41598-024-51423-xhttp...
2024 doi
-
[135]
J. M. Cowley, IMAGE CONTRAST IN A TRANS- MISSION SCANNING ELECTRON MICRO- SCOPE, Applied Physics Letters 15 (2) (1969) 58–59.doi:10.1063/1.1652901. URLhttp://aip.scitation.org/doi/10.1063/ 1.1652901
1969 doi
-
[136]
F. F. Krause, A. Rosenauer, Reciprocity relations in transmission electron microscopy: A rigorous derivation, Micron 92 (Supplement C) (2017) 1–5. doi:10.1016/j.micron.2016.09.007. URLhttp://www.sciencedirect.com/science/ article/pii/S0968432816301421
2017 doi
-
[137]
J. Zhao, C. Huang, A. Mostaed, A. Moshtaghpour, J. M. Parkhurst, I. Lobato, M. Gallagher-Jones, J. S. Kim, M. Boyce, D. Stuart, E. A. Andreeva, J.-p. Colletier, A. I. Kirkland, Electron fourier ptychography for phase reconstruction, Scientific Reports 15 (1) (2025) 37955.arXiv...
2025
-
[138]
Basavappa, D
R. Basavappa, D. Filman, R. Syed, O. Flore, J. Icenogle, J. Hogle, Role and mechanism of the maturation cleavage of VP0 in poliovirus assembly: Structure of the empty capsid assembly intermediate at 2.9 Å resolution, Protein Science 3 (10) (1994) 24 1651–1669.doi:10.1002/pro.5...
1994 doi
-
[139]
J. M. Cowley, A. F. Moodie, The scattering of elec- trons by atoms and crystals. I. A new theoretical approach, Acta Crystallographica 10 (10) (1957) 609–619.doi:10.1107/s0365110x57002194. URLhttp://dx.doi.org/10.1107/ S0365110X57002194
1957 doi
-
[140]
Goodman, A
P. Goodman, A. F. Moodie, Numerical evaluations of N-beam wave functions in electron scattering by the multi-slice method, Acta Crystallographica Section A 30 (2) (1974) 280–290.doi:10.1107/ S056773947400057X
1974
-
[141]
Ishizuka, N
K. Ishizuka, N. Uyeda, A new theoretical and practical approach to the multislice method, Acta Crystallogr., Sect. A 33 (5) (1977) 740–749. doi:10.1107/S0567739477001879. URLhttp://dx.doi.org/10.1107/ S0567739477001879
1977 doi
-
[142]
E. J. Kirkland, Advanced Computing in Electron Microscopy, Springer International Publishing, Cham, 2020.doi:10.1007/978-3-030-33260-0. URLhttp://link.springer.com/10.1007/ 978-3-030-33260-0
2020 doi
-
[143]
Butan, D
C. Butan, D. J. Filman, J. M. Hogle, Cryo-Electron Microscopy Reconstruction Shows Poliovirus 135S Particles Poised for Membrane Interaction and RNA Release, Journal of Virology 88 (3) (2014) 1758–1770.doi:10.1128/JVI.01949-13. URLhttps://journals.asm.org/doi/10.1128/ JVI.01949-13
2014 doi
-
[144]
Dimova, R
N. Dimova, R. Plackett, D. Weatherill, D. Wood, L. O’Ryan, G. Crevatin, J. Barnard, M. Gallagher- Jones, D. Hynds, R. Goldsbrough, I. Shipsey, D. Bortoletto, A. Kirkland, Measurement of the resolution of the Timepix4 detector for 100 keV and 200 keV electrons for transmission ...
2025 arXiv
-
[145]
S. Li, N. Gauquelin, H. L. Lalandec Robert, A. An- nys, C. Gao, C. Hofer, T. J. Pennycook, J. Verbeeck, Improving the low-dose performance of aberration correction in single sideband ptychography, Ultra- microscopy 277 (2025) 114225.arXiv:2505.09555, doi:10.1016/j.ultramic.202...
2025
-
[146]
Thibault, M
P. Thibault, M. Dierolf, O. Bunk, A. Menzel, F. Pfeiffer, Probe retrieval in ptychographic coherent diffractive imaging, Ultramicroscopy 109 (4) (2009) 338–343.doi:10.1016/j.ultramic.2008.12.011
2009 doi
-
[147]
A. M. Maiden, J. M. Rodenburg, An improved pty- chographical phase retrieval algorithm for diffractive imaging, Ultramicroscopy 109 (10) (2009) 1256– 1262.doi:10.1016/j.ultramic.2009.05.012. URLhttps://linkinghub.elsevier.com/ retrieve/pii/S0304399109001284
2009 doi
-
[148]
Thibault, A
P. Thibault, A. Menzel, Reconstructing state mixtures from diffraction measurements, Na- ture 494 (7435) (2013) 68–71.doi:10.1038/ nature11806. URLhttp://dx.doi.org/10.1038/nature11806
2013 doi
-
[149]
Z. Chen, M. Odstrcil, Y. Jiang, Y. Han, M. H. Chiu, L. J. Li, D. A. Muller, Mixed-state electron ptychography enables sub-angstrom resolution imaging with picometer precision at low dose, Nature Communications 11 (1) (2020) 1–10. doi:10.1038/s41467-020-16688-6. URLhttp://dx.do...
2020 doi
-
[150]
A. M. Maiden, M. J. Humphry, F. Zhang, J. M. Ro- denburg, Superresolution imaging via ptychography, Journal of the Optical Society of America A 28 (4) (2011) 604.doi:10.1364/josaa.28.000604
2011 doi
-
[151]
Humphry, B
M. Humphry, B. Kraus, A. Hurst, A. Maiden, J. Ro- denburg, Ptychographic electron microscopy using high-angle dark-field scattering for sub-nanometre resolution imaging, Nature Communications 3 (1) (2012) 730.doi:10.1038/ncomms1733. URLhttp://dx.doi.org/10.1038/ ncomms1733http...
2012 doi
-
[152]
Jiang, Z
Y. Jiang, Z. Chen, Y. Han, P. Deb, H. Gao, S. Xie, P. Purohit, M. W. Tate, J. Park, S. M. Gruner, V. Elser, D. A. Muller, Electron ptychography of 2D materials to deep sub-ångström resolution (jul 2018).doi:10.1038/s41586-018-0298-5. URLhttp://www.nature.com/articles/ s41586-0...
2018 doi
-
[153]
A. M. Maiden, M. J. Humphry, J. M. Rodenburg, Ptychographic transmission microscopy in three dimensions using a multi-slice approach, Journal of the Optical Society of America A 29 (8) (2012) 1606.doi:10.1364/JOSAA.29.001606. URLhttps://opg.optica.org/abstract.cfm? URI=josaa-2...
2012 doi
-
[154]
S. Gao, P. Wang, F. Zhang, G. T. Martinez, P. D. Nellist, X. Pan, A. I. Kirkland, Electron ptychographic microscopy for three-dimensional imaging, Nature Communications 8 (1) (2017) 163. doi:10.1038/s41467-017-00150-1. URLhttps://doi.org/10.1038/ s41467-017-00150-1http://dx.do...
2017 doi
-
[155]
Sayre, Some implications of a theorem due to Shannon, Acta Crystallographica 5 (6) (1952) 843
D. Sayre, Some implications of a theorem due to Shannon, Acta Crystallographica 5 (6) (1952) 843. doi:10.1107/S0365110X52002276. URLhttps://doi.org/10.1107/ S0365110X52002276
1952 doi
-
[156]
Gerchberg, Super-resolution through Er- ror Energy Reduction, Optica Acta: Interna- tional Journal of Optics 21 (9) (1974) 709–720
R. Gerchberg, Super-resolution through Er- ror Energy Reduction, Optica Acta: Interna- tional Journal of Optics 21 (9) (1974) 709–720. doi:10.1080/713818946. URLhttps://www.tandfonline.com/doi/full/ 10.1080/713818946
1974 doi
-
[157]
Close, Z
R. Close, Z. Chen, N. Shibata, S. D. Findlay, To- wards quantitative, atomic-resolution reconstruction of the electrostatic potential via differential phase contrast using electrons, Ultramicroscopy 159 (2015) 124–137.doi:10.1016/j.ultramic.2015.09.002. URLhttp://dx.doi.org/10...
2015 doi
-
[158]
Addiego, W
C. Addiego, W. Gao, X. Pan, Thickness and defocus dependence of inter-atomic electric fields measured by scanning diffraction, Ultra- microscopy 208 (September 2019) (2020) 112850. doi:10.1016/j.ultramic.2019.112850. URLhttps://doi.org/10.1016/j.ultramic. 2019.112850
2019
-
[159]
Bürger, T
J. Bürger, T. Riedl, J. K. Lindner, Influence of lens aberrations, specimen thickness and tilt on differential phase contrast STEM images, Ultramicroscopy 219 (February) (2020) 113118. doi:10.1016/j.ultramic.2020.113118. URLhttps://doi.org/10.1016/j.ultramic. 2020.113118
2020
-
[160]
Liang, D
Z. Liang, D. Song, B. Ge, Optimizing experi- mental parameters of integrated differential phase contrast (iDPC) for atomic resolution imaging, Ultramicroscopy 246 (June 2022) (2023) 113686. doi:10.1016/j.ultramic.2023.113686. URLhttps://doi.org/10.1016/j.ultramic. 2023.113686
2022
-
[161]
Clark, G
L. Clark, G. T. Martinez, C. M. O’Leary, H. Yang, Z. Ding, T. C. Petersen, S. D. Findlay, P. D. Nellist, The Effect of Dynamical Scattering on Single-plane Phase Retrieval in Electron Ptychography, Mi- croscopy and Microanalysis 29 (1) (2023) 384–394. doi:10.1093/micmic/ozac02...
2023 doi
-
[162]
C. Gao, C. Hofer, T. Pennycook, On cen- tral focusing for contrast optimization in direct electron ptychography of thick samples, Ultramicroscopy 256 (November
-
[163]
S. H. Shahmoradian, E. H. Tsai, A. Diaz, M. Guizar- Sicairos, J. Raabe, L. Spycher, M. Britschgi, A. Ruf, H. Stahlberg, M. Holler, Three-dimensional imaging of biological tissue by cryo x-ray pty- chography, Scientific Reports 7 (1) (2017) 1–12. doi:10.1038/s41598-017-05587-4....
2017 doi
-
[164]
T. Wang, S. Jiang, P. Song, R. Wang, L. Yang, T. Zhang, G. Zheng, Optical ptychography for biomedical imaging: recent progress and future directions [Invited], Biomedical Optics Express 14 (2) (2023) 489.doi:10.1364/BOE.480685. URLhttps://opg.optica.org/abstract.cfm? URI=boe-14-2-489
2023 doi
-
[165]
Kunze, C
S. Kunze, C. Nam, H. Kim, J. Chung, E. Hong, J. Song, H. Choi, J. Lim, X-ray imaging methods for multiscale characterization of batteries, Bulletin of the Korean Chemical Society 46 (4) (2025) 360–380. doi:10.1002/bkcs.70009. URLhttps://onlinelibrary.wiley.com/doi/ 10.1002/bkcs.70009
2025 doi
-
[166]
K. Sun, H. Sha, J. Cui, J. Zhang, Z. Liu, Y. Dong, R. Yu, The challenge of imaging electron-beam sensitive LiCoO2 cathode at atomic scale and a pty- chography solution, Journal of Energy Chemistry (jul 2025).doi:10.1016/j.jechem.2025.07.037. URLhttps://doi.org/10.1016/j.jechem...
2025 doi
-
[167]
Donnelly, V
C. Donnelly, V. Scagnoli, M. Guizar-Sicairos, M. Holler, F. Wilhelm, F. Guillou, A. Rogalev, C. Detlefs, A. Menzel, J. Raabe, L. J. Heyderman, High-resolution hard x-ray magnetic imaging with dichroic ptychography, Physical Review B 94 (6) (2016) 064421.doi:10.1103/PhysRevB.94...
2016 doi
-
[168]
H. KP, R. Xu, K. Patel, K. J. Crust, A. Khandelwal, C. Zhang, S. Prosandeev, H. Zhou, Y.-T. Shao, 26 L. Bellaiche, H. Y. Hwang, D. A. Muller, Electron ptychography reveals a ferroelectricity dominated by anion displacements, Nature Materials (apr 2025).doi:10.1038/s41563-025-0...
2025 doi
-
[169]
T. A. Butcher, N. W. Phillips, C.-C. Wei, S.- C. Chang, I. Beinik, K. Thånell, J.-C. Yang, S.-W. Huang, J. Raabe, S. Finizio, Imaging fer- roelectric domains with soft-x-ray ptychography at the oxygen K-edge, Physical Review Applied 23 (1) (2025) L011002.arXiv:2408.09608, doi:...
2025 arXiv
-
[170]
Black, E
G. Black, E. H. Linfoot, Spherical aberration and the information content of optical images, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences 239 (1219) (1957) 522–540.doi:10.1098/rspa.1957.0059. URLhttps://royalsocietypublishing.org/ do...
1957
-
[2023]
URLhttp://arxiv.org/abs/2306.08587https: //linkinghub.elsevier.com/retrieve/pii/ S0304399123001961
(2024) 113879.arXiv:2306.08587, doi:10.1016/j.ultramic.2023.113879. URLhttp://arxiv.org/abs/2306.08587https: //linkinghub.elsevier.com/retrieve/pii/ S0304399123001961
2024 arXiv
Reviewed August 3, 2026 · model on record in the stance chip above.
Discussion (0). Sign in to comment.