Pith. sign in

REVIEW 2 major objections 53 references

ActiveVital: Geometry-Aware Embodied Vital Signs Monitoring for Home Healthcare Robots

T0 review · 2 major / 0 minor · reviewed 2026-06-30 · grok-4.3

Pith's one-line read By treating radar observation geometry as a controllable variable, home robots can monitor vital signs accurately without contact.

desk verdict ActiveVital turns mmWave geometry into an active control loop via vision keypoints, with large reported error drops, but the abstract leaves the supporting experiments and loop reliability unaddressed. read the letter →

arxiv 2606.30275 v1 pith:SQT6ZSNR submitted 2026-06-29 cs.RO

classification cs.RO
keywords vitalsignsmonitoringmmWaveradarembodiedsensingrobotvisioncontactlesshomehealthcaregeometricregulation
verification ladder T0 review T1 audit T2 compute T3 formal

The pith

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The reading

The paper sets out to prove that mmWave radar can deliver reliable respiration and heart rate data from moving robots if the observation angle is actively optimized. It shows that visual detection of the chest allows the robot to adjust its position for maximum radial motion sensitivity. Closing this perception-action loop with a phase enhancement step brings performance close to stationary ideal conditions. This would matter because it removes the need for fixed sensor placements in everyday home environments.

What carries the argument

The perception-action loop that uses visual keypoints to regulate sensing geometry by steering the robot for near-normal radar incidence.

What would settle it

Observation of vital signs errors staying high when the robot attempts alignment but keypoint detection fails or obstacles prevent proper positioning.

Watch

Extended reading notes

Core claim

We reformulate vital signs monitoring from passive signal recovery to active geometric regulation. ActiveVital localizes the chest anchor via visual keypoints and converts alignment errors into control commands. This steers the robot-mounted radar toward near-normal incidence to the thoracic surface, maximizing radial observability within a perception-action loop. A differential phase enhancement module further stabilizes signal extraction under motion. Experiments show respiration interval error reduced from 0.87 s to 0.14 s and heart rate error from 13.59 bpm to 2.22 bpm.

Load-bearing premise

That visual keypoints can accurately localize the chest anchor and that the resulting alignment errors can be turned into control commands achieving near-normal incidence in real home environments.

Share X Bluesky LinkedIn Reddit HN

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, simulated authors' rebuttal, and a circularity audit.

Referee Report

2 major / 0 minor

Summary. The paper proposes ActiveVital, a vision-guided sensing framework for home healthcare robots that reformulates mmWave vital signs monitoring as an active geometric control problem. Visual keypoints localize the chest anchor, alignment errors are converted to robot control commands to steer toward near-normal incidence, and a differential phase enhancement module stabilizes extraction; experiments report respiration interval error reduced from 0.87 s to 0.14 s and heart rate error from 13.59 bpm to 2.22 bpm under unconstrained configurations.

Significance. If the central claims hold, the work would demonstrate that treating sensing geometry as a controllable variable can overcome fundamental radial-observability limits of mmWave radar, enabling reliable non-contact vital signs monitoring in dynamic home environments where static placements fail.

major comments (2)
  1. [Abstract] Abstract and framework description: the headline error reductions are attributed to achieving near-normal incidence via the perception-action loop, yet no quantitative results are given on keypoint localization accuracy, distribution of achieved incidence angles, or success rate of the control loop across clothing, pose, lighting, or partial occlusion; without these, the geometric premise cannot be verified and the performance gains cannot be causally linked to active regulation.
  2. [Experiments] Experiments section: the abstract states specific numerical improvements but provides no information on subject count, statistical significance tests, experimental protocol details, or potential confounds (e.g., subject motion, clothing types), so the data support for robustness under unconstrained robot-human configurations cannot be assessed.

Simulated Author's Rebuttal

2 responses · 0 unresolved

We thank the referee for the constructive feedback. The comments correctly identify areas where additional quantitative details and experimental transparency are needed to strengthen the causal claims and assess robustness. We will revise the manuscript to incorporate these elements.

read point-by-point responses
  1. Referee: [Abstract] Abstract and framework description: the headline error reductions are attributed to achieving near-normal incidence via the perception-action loop, yet no quantitative results are given on keypoint localization accuracy, distribution of achieved incidence angles, or success rate of the control loop across clothing, pose, lighting, or partial occlusion; without these, the geometric premise cannot be verified and the performance gains cannot be causally linked to active regulation.

    Authors: We agree that the abstract and framework description would be strengthened by explicit quantitative validation of the perception-action loop. In the revised manuscript, we will add results on keypoint localization accuracy, the distribution of achieved incidence angles, and control loop success rates, reported across clothing, pose, lighting, and partial occlusion conditions. This will help verify the geometric premise and link the error reductions to active regulation of sensing geometry. revision: yes

  2. Referee: [Experiments] Experiments section: the abstract states specific numerical improvements but provides no information on subject count, statistical significance tests, experimental protocol details, or potential confounds (e.g., subject motion, clothing types), so the data support for robustness under unconstrained robot-human configurations cannot be assessed.

    Authors: We agree that the experiments section requires expanded reporting to support the robustness claims. The revised manuscript will specify subject count, include statistical significance tests, provide detailed experimental protocol information, and discuss potential confounds such as subject motion and clothing types. These additions will allow better assessment of performance under unconstrained robot-human configurations. revision: yes

Circularity Check

0 steps flagged · score 0.0 of 10

No circularity: empirical performance claims rest on measured outcomes, not definitional reduction

full rationale

The paper describes a vision-guided control loop that localizes chest keypoints and issues commands to achieve near-normal mmWave incidence, then reports measured error reductions (0.87 s → 0.14 s respiration interval; 13.59 bpm → 2.22 bpm heart rate) from experiments. These outcomes are presented as results of the method rather than quantities defined by or fitted to the same inputs. No equations equate a prediction to its own fit, no self-citation supplies a load-bearing uniqueness theorem, and no ansatz is smuggled via prior work. The derivation chain is therefore self-contained against external benchmarks.

Assumptions & free parameters 0 free parameters · 2 assumptions · 0 invented entities

Ledger populated from abstract alone; no full text details on parameters or entities available.

assumptions (2)
  • domain assumption mmWave radar phase sensitivity enables detection of sub-millimeter thoracic motions
    Stated as the basis for using mmWave in the abstract.
  • domain assumption Only the radial component of motion is observable by the radar
    Fundamental constraint invoked to motivate the geometry problem.

how reviews work

0 comments
Cite this review

Pith. "Pith review of ActiveVital: Geometry-Aware Embodied Vital Signs Monitoring for Home Healthcare Robots." pith.science (2026). https://pith.science/paper/SQT6ZSNR

@misc{pith2026260630275,
  author       = {Pith},
  title        = {Pith review of: ActiveVital: Geometry-Aware Embodied Vital Signs Monitoring for Home Healthcare Robots},
  year         = {2026},
  howpublished = {\url{https://pith.science/paper/SQT6ZSNR}},
  note         = {Machine review of arXiv:2606.30275}
}
read the original abstract

Home robots require reliable vital signs monitoring to support long-term companionship and safety in daily environments, yet obtaining respiration and heart rate without physical contact remains challenging in unconstrained home settings. Millimeter-wave (mmWave) radar offers a promising solution due to its phase sensitivity to sub-millimeter motions. However, mmWave measurements are fundamentally constrained by observation geometry, since only the radial component of motion is observable. Consequently, arbitrary robot-human orientations often introduce angular misalignment that destabilizes vital signs estimation. To address this limitation, we reformulate vital signs monitoring from passive signal recovery to active geometric regulation. We propose ActiveVital, a vision-guided sensing framework that treats sensing geometry as an explicit control variable for robots. It localizes the chest anchor via visual keypoints and converts alignment errors into control commands. This steers the robot-mounted radar toward near-normal incidence to the thoracic surface, maximizing radial observability within a perception-action loop. A differential phase enhancement module further stabilizes signal extraction under motion. Experiments show that ActiveVital reduces respiration interval error from 0.87 s to 0.14 s and heart rate error from 13.59 bpm to 2.22 bpm, achieving accuracy comparable to controlled static sensing while remaining robust under unconstrained robot-human configurations.

Discussion (0). Continue with ORCID to comment.

Reference graph

Works this paper leans on

53 extracted references · 3 canonical work pages

  1. [1]

    and Sparks, Ross S

    Celler, Branko G. and Sparks, Ross S. , journal=. Home Telemonitoring of Vital Signs—Technical Challenges and Future Directions , year=

  2. [2]

    Nature Electronics , author=

    Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor , volume=. Nature Electronics , author=. 2019 , month=

  3. [3]

    Radar-Based Vital Signal Extraction via Morphological Component Analysis , year=

    Li, Hongzhi and Ayuknso, Ayukocha Gandhi Bessemntoh and Yang, Nanyi and Wei, Zeying and Zhi, Minghan and Hua, Qinglong and Zhao, Bin , journal=. Radar-Based Vital Signal Extraction via Morphological Component Analysis , year=

  4. [4]

    State-of-the-Art Technologies and Emerging Trends in Radar-Based Vital Signs Sensing: A Review , year=

    Yuan, Tongyang and Kuo, Youyu and Ren, Aifeng and Huo, Runqi and Sun, Qing and Zahid, Adnan , journal=. State-of-the-Art Technologies and Emerging Trends in Radar-Based Vital Signs Sensing: A Review , year=

  5. [5]

    Contactless Respiration Rate Monitoring and Human Body Pose Detection for Search and Rescue Robots , year=

    Cittadini, Roberto and Buonocore, Luca Rosario and Di Castro, Mario and Zollo, Loredana , booktitle=. Contactless Respiration Rate Monitoring and Human Body Pose Detection for Search and Rescue Robots , year=

  6. [6]

    and Eckrich, Christian and Kakouche, Ibrahim and Fabian, Stefan and von Stryk, Oskar and Zoubir, Abdelhak M

    Schroth, Christian A. and Eckrich, Christian and Kakouche, Ibrahim and Fabian, Stefan and von Stryk, Oskar and Zoubir, Abdelhak M. and Muma, Michael , journal=. Emergency Response Person Localization and Vital Sign Estimation Using a Semi-Autonomous Robot Mounted SFCW Radar , year=

  7. [7]

    Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea , year=

    Scebba, Gaetano and Da Poian, Giulia and Karlen, Walter , journal=. Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea , year=

  8. [8]

    A Non-contact Method for Extracting Heart and Respiration Rates , year=

    Hessler, Christian and Abouelenien, Mohamed and Burzo, Mihai , booktitle=. A Non-contact Method for Extracting Heart and Respiration Rates , year=

Show all 53 references
  1. [9]

    Communications Biology , author=

    Using smart speakers to contactlessly monitor heart rhythms , volume=. Communications Biology , author=. 2021 , month=mar, pages=

  2. [10]

    Monitoring Vital Signs and Postures During Sleep Using WiFi Signals , year=

    Liu, Jian and Chen, Yingying and Wang, Yan and Chen, Xu and Cheng, Jerry and Yang, Jie , journal=. Monitoring Vital Signs and Postures During Sleep Using WiFi Signals , year=

  3. [11]

    Signal Preprocessing for Heartbeat Detection Using Continuous-Wave Doppler Radar , year=

    Lee, In-Seong and Yang, Jong-Ryul , journal=. Signal Preprocessing for Heartbeat Detection Using Continuous-Wave Doppler Radar , year=

  4. [12]

    Big Data and Cognitive Computing , VOLUME =

    Tran, Vinh Phuc and Al-Jumaily, Adel Ali and Islam, Syed Mohammed Shamsul , TITLE =. Big Data and Cognitive Computing , VOLUME =. 2019 , NUMBER =

  5. [13]

    Differential Enhancement Method for Robust and Accurate Heart Rate Monitoring via Microwave Vital Sign Sensing , year=

    Xiong, Yuyong and Peng, Zhike and Gu, Changzhan and Li, Songxu and Wang, Dong and Zhang, Wenming , journal=. Differential Enhancement Method for Robust and Accurate Heart Rate Monitoring via Microwave Vital Sign Sensing , year=

  6. [14]

    and Schroeder, Udo and Mysore R, Bhavani Shankar , journal=

    Mirhosseini, Seyedeh Fatemeh and Alaee-Kerahroodi, Mohammad and Olk, Andreas E. and Schroeder, Udo and Mysore R, Bhavani Shankar , journal=. In-Car Life Detection and Vital Signs Monitoring Using mmWave Radar Sensors , year=

  7. [15]

    Investigating Respiration-Heartbeat Separation Through a Multipoint Scattering Chest Wall Motion Model: 60-GHz FMCW Radar Assessment , year=

    Hu, Yuxuan and Xia, Zhaoyang and Xu, Feng , journal=. Investigating Respiration-Heartbeat Separation Through a Multipoint Scattering Chest Wall Motion Model: 60-GHz FMCW Radar Assessment , year=

  8. [16]

    A Hybrid Radar-Camera Respiratory Monitoring System Based on an Impulse-Radio Ultrawideband Radar , year=

    Yang, Chenxi and Bruce, Brendan and Liu, Xiaofan and Gholami, Behnood and Tavassolian, Negar , booktitle=. A Hybrid Radar-Camera Respiratory Monitoring System Based on an Impulse-Radio Ultrawideband Radar , year=

  9. [17]

    Vital Signs Identification System With Doppler Radars and Thermal Camera , year=

    Chian, De-Ming and Wen, Chao-Kai and Wang, Chang-Jen and Hsu, Ming-Huan and Wang, Fu-Kang , journal=. Vital Signs Identification System With Doppler Radars and Thermal Camera , year=

  10. [18]

    Camera-Augmented Non-Contact Vital Sign Monitoring in Real Time , year=

    Shokouhmand, Arash and Eckstrom, Samuel and Gholami, Behnood and Tavassolian, Negar , journal=. Camera-Augmented Non-Contact Vital Sign Monitoring in Real Time , year=

  11. [19]

    Vital Sign Monitoring in Dynamic Environment via mmWave Radar and Camera Fusion , year=

    Wang, Yingqi and Wang, Zhongqin and Zhang, Jian Andrew and Zhang, Haimin and Xu, Min , journal=. Vital Sign Monitoring in Dynamic Environment via mmWave Radar and Camera Fusion , year=

  12. [20]

    Vision-Assisted Chest Wall Localization for Microwave Vital Sign Monitoring , year=

    Gou, Yingjie and Xiong, Yuyong and Lin, Wenjie and Hong, Sicheng and Peng, Zhike , journal=. Vision-Assisted Chest Wall Localization for Microwave Vital Sign Monitoring , year=

  13. [21]

    Chai and Claas Ehmke and Philipp Rupp and Farah Z

    Hen-Wei Huang and Jack Chen and Peter R. Chai and Claas Ehmke and Philipp Rupp and Farah Z. Dadabhoy and Annie Feng and Canchen Li and Akhil J. Thomas and Marco da Silva and Edward W. Boyer and Giovanni Traverso , title =. Cyborg and Bionic Systems , volume =

  14. [22]

    Proceedings of the 36th International Conference on Neural Information Processing Systems , articleno =

    Xu, Yufei and Zhang, Jing and Zhang, Qiming and Tao, Dacheng , title =. Proceedings of the 36th International Conference on Neural Information Processing Systems , articleno =. 2022 , isbn =

  15. [23]

    2018 , volume=

    Jankiraman, Mohinder , booktitle=. 2018 , volume=

  16. [24]

    Keller , journal =

    Joseph B. Keller , journal =. Geometrical Theory of Diffraction , volume =

  17. [25]

    , journal=

    Al-Nashi, H. , journal=. Phase unwrapping of digital signals , year=

  18. [26]

    Proceedings of the 37th International Conference on Neural Information Processing Systems , articleno =

    Yang, Jianfei and Huang, He and Zhou, Yunjiao and Chen, Xinyan and Xu, Yuecong and Yuan, Shenghai and Zou, Han and Lu, Chris Xiaoxuan and Xie, Lihua , title =. Proceedings of the 37th International Conference on Neural Information Processing Systems , articleno =. 2023 , publisher =

  19. [27]

    Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) , year =

    Fan, Junqiao and Zhou, Yunjiao and Yang, Yizhuo and Cui, Xinyuan and Zhang, Jiarui and Xie, Lihua and Yang, Jianfei and Lu, Chris Xiaoxuan and Ding, Fangqiang , title =. Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) , year =

  20. [31]

    X-fi: A modality-invariant foundation model for multimodal human sensing

    Xinyan Chen and Jianfei Yang. X-fi: A modality-invariant foundation model for multimodal human sensing. arXiv preprint arXiv:2410.10167, 2025

  21. [32]

    Vital signs identification system with doppler radars and thermal camera

    De-Ming Chian, Chao-Kai Wen, Chang-Jen Wang, Ming-Huan Hsu, and Fu-Kang Wang. Vital signs identification system with doppler radars and thermal camera. IEEE Transactions on Biomedical Circuits and Systems, 16 0 (1): 0 153--167, 2022

  22. [33]

    Contactless respiration rate monitoring and human body pose detection for search and rescue robots

    Roberto Cittadini, Luca Rosario Buonocore, Mario Di Castro, and Loredana Zollo. Contactless respiration rate monitoring and human body pose detection for search and rescue robots. In 2024 10th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (...

  23. [34]

    M4human: A large-scale multimodal mmwave radar benchmark for human mesh reconstruction

    Junqiao Fan, Yunjiao Zhou, Yizhuo Yang, Xinyuan Cui, Jiarui Zhang, Lihua Xie, Jianfei Yang, Chris Xiaoxuan Lu, and Fangqiang Ding. M4human: A large-scale multimodal mmwave radar benchmark for human mesh reconstruction. In Proceedings of the IEEE/CVF Conference on Computer Visi...

  24. [35]

    Vision-assisted chest wall localization for microwave vital sign monitoring

    Yingjie Gou, Yuyong Xiong, Wenjie Lin, Sicheng Hong, and Zhike Peng. Vision-assisted chest wall localization for microwave vital sign monitoring. IEEE Sensors Journal, 26 0 (2): 0 2709--2723, 2026

  25. [36]

    A non-contact method for extracting heart and respiration rates

    Christian Hessler, Mohamed Abouelenien, and Mihai Burzo. A non-contact method for extracting heart and respiration rates. In 2020 17th Conference on Computer and Robot Vision (CRV), pages 1--8, 2020

  26. [37]

    Investigating respiration-heartbeat separation through a multipoint scattering chest wall motion model: 60-ghz fmcw radar assessment

    Yuxuan Hu, Zhaoyang Xia, and Feng Xu. Investigating respiration-heartbeat separation through a multipoint scattering chest wall motion model: 60-ghz fmcw radar assessment. IEEE Transactions on Instrumentation and Measurement, 73: 0 1--13, 2024

  27. [38]

    Waveman: mmwave-based room-scale human interaction perception for humanoid robots

    Yuxuan Hu, Kuangji Zuo, Boyu Ma, Shihao Li, Zhaoyang Xia, Feng Xu, and Jianfei Yang. Waveman: mmwave-based room-scale human interaction perception for humanoid robots. arXiv preprint arXiv:2601.07454, 2026

  28. [39]

    Chai, Claas Ehmke, Philipp Rupp, Farah Z

    Hen-Wei Huang, Jack Chen, Peter R. Chai, Claas Ehmke, Philipp Rupp, Farah Z. Dadabhoy, Annie Feng, Canchen Li, Akhil J. Thomas, Marco da Silva, Edward W. Boyer, and Giovanni Traverso. Mobile robotic platform for contactless vital sign monitoring. Cyborg and Bionic Systems, 202...

  29. [40]

    Signal preprocessing for heartbeat detection using continuous-wave doppler radar

    In-Seong Lee and Jong-Ryul Yang. Signal preprocessing for heartbeat detection using continuous-wave doppler radar. IEEE Microwave and Wireless Technology Letters, 33 0 (4): 0 479--482, 2023

  30. [41]

    Radar-based vital signal extraction via morphological component analysis

    Hongzhi Li, Ayukocha Gandhi Bessemntoh Ayuknso, Nanyi Yang, Zeying Wei, Minghan Zhi, Qinglong Hua, and Bin Zhao. Radar-based vital signal extraction via morphological component analysis. IEEE Transactions on Microwave Theory and Techniques, 73 0 (11): 0 9263--9278, 2025

  31. [42]

    Monitoring vital signs and postures during sleep using wifi signals

    Jian Liu, Yingying Chen, Yan Wang, Xu Chen, Jerry Cheng, and Jie Yang. Monitoring vital signs and postures during sleep using wifi signals. IEEE Internet of Things Journal, 5 0 (3): 0 2071--2084, 2018

  32. [43]

    Em-fall: Embodied mmwave sensing for day-and-night fall detection on humanoid robots

    Yanshuo Lu, Yuxuan Hu, Shenghai Yuan, Xinyu Zhou, Kuangji Zuo, Bofan Lyu, XiChen Yuan, and Jianfei Yang. Em-fall: Embodied mmwave sensing for day-and-night fall detection on humanoid robots. arXiv preprint arXiv:2606.11109, 2026

  33. [44]

    Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor

    Marco Mercuri, Ilde Rosa Lorato, Yao-Hong Liu, Fokko Wieringa, Chris Van Hoof, and Tom Torfs. Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor. Nature Electronics, 2 0 (6): 0 252–262, June 2019. ISSN 2520-1131

  34. [45]

    Olk, Udo Schroeder, and Bhavani Shankar Mysore R

    Seyedeh Fatemeh Mirhosseini, Mohammad Alaee-Kerahroodi, Andreas E. Olk, Udo Schroeder, and Bhavani Shankar Mysore R. In-car life detection and vital signs monitoring using mmwave radar sensors. IEEE Transactions on Radar Systems, 4: 0 207--231, 2026

  35. [46]

    Multispectral video fusion for non-contact monitoring of respiratory rate and apnea

    Gaetano Scebba, Giulia Da Poian, and Walter Karlen. Multispectral video fusion for non-contact monitoring of respiratory rate and apnea. IEEE Transactions on Biomedical Engineering, 68 0 (1): 0 350--359, 2021

  36. [47]

    Schroth, Christian Eckrich, Ibrahim Kakouche, Stefan Fabian, Oskar von Stryk, Abdelhak M

    Christian A. Schroth, Christian Eckrich, Ibrahim Kakouche, Stefan Fabian, Oskar von Stryk, Abdelhak M. Zoubir, and Michael Muma. Emergency response person localization and vital sign estimation using a semi-autonomous robot mounted sfcw radar. IEEE Transactions on Biomedical E...

  37. [48]

    Camera-augmented non-contact vital sign monitoring in real time

    Arash Shokouhmand, Samuel Eckstrom, Behnood Gholami, and Negar Tavassolian. Camera-augmented non-contact vital sign monitoring in real time. IEEE Sensors Journal, 22 0 (12): 0 11965--11978, 2022

  38. [49]

    Doppler radar-based non-contact health monitoring for obstructive sleep apnea diagnosis: A comprehensive review

    Vinh Phuc Tran, Adel Ali Al-Jumaily, and Syed Mohammed Shamsul Islam. Doppler radar-based non-contact health monitoring for obstructive sleep apnea diagnosis: A comprehensive review. Big Data and Cognitive Computing, 3 0 (1), 2019. ISSN 2504-2289

  39. [50]

    Sridhar, and Shyamnath Gollakota

    Anran Wang, Dan Nguyen, Arun R. Sridhar, and Shyamnath Gollakota. Using smart speakers to contactlessly monitor heart rhythms. Communications Biology, 4 0 (1): 0 319, March 2021. ISSN 2399-3642

  40. [51]

    Vital sign monitoring in dynamic environment via mmwave radar and camera fusion

    Yingqi Wang, Zhongqin Wang, Jian Andrew Zhang, Haimin Zhang, and Min Xu. Vital sign monitoring in dynamic environment via mmwave radar and camera fusion. IEEE Transactions on Mobile Computing, 23 0 (5): 0 4163--4180, 2024

  41. [52]

    Differential enhancement method for robust and accurate heart rate monitoring via microwave vital sign sensing

    Yuyong Xiong, Zhike Peng, Changzhan Gu, Songxu Li, Dong Wang, and Wenming Zhang. Differential enhancement method for robust and accurate heart rate monitoring via microwave vital sign sensing. IEEE Transactions on Instrumentation and Measurement, 69 0 (9): 0 7108--7118, 2020

  42. [53]

    Vitpose: simple vision transformer baselines for human pose estimation

    Yufei Xu, Jing Zhang, Qiming Zhang, and Dacheng Tao. Vitpose: simple vision transformer baselines for human pose estimation. In Proceedings of the 36th International Conference on Neural Information Processing Systems, NIPS '22, Red Hook, NY, USA, 2022. Curran Associates Inc. ...

  43. [54]

    A hybrid radar-camera respiratory monitoring system based on an impulse-radio ultrawideband radar

    Chenxi Yang, Brendan Bruce, Xiaofan Liu, Behnood Gholami, and Negar Tavassolian. A hybrid radar-camera respiratory monitoring system based on an impulse-radio ultrawideband radar. In 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Societ...

  44. [55]

    Mm-fi: multi-modal non-intrusive 4d human dataset for versatile wireless sensing

    Jianfei Yang, He Huang, Yunjiao Zhou, Xinyan Chen, Yuecong Xu, Shenghai Yuan, Han Zou, Chris Xiaoxuan Lu, and Lihua Xie. Mm-fi: multi-modal non-intrusive 4d human dataset for versatile wireless sensing. In Proceedings of the 37th International Conference on Neural Information ...

  45. [56]

    State-of-the-art technologies and emerging trends in radar-based vital signs sensing: A review

    Tongyang Yuan, Youyu Kuo, Aifeng Ren, Runqi Huo, Qing Sun, and Adnan Zahid. State-of-the-art technologies and emerging trends in radar-based vital signs sensing: A review. IEEE Sensors Journal, 26 0 (3): 0 3446--3459, 2026

Pith tools