Pith. sign in

REVIEW 1 cited by

A geometric multiscale model for the numerical simulation of blood flow in the human left heart

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2110.02114 v2 pith:2HKJHVOS submitted 2021-10-05 math.NA cs.NAphysics.flu-dynphysics.med-ph

classification math.NAcs.NAphysics.flu-dynphysics.med-ph
keywords modelleftnumericalventriclebloodcardiaccirculationcoupled
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

We present a new computational model for the numerical simulation of blood flow in the human left heart. To this aim, we use the Navier-Stokes equations in an Arbitrary Lagrangian Eulerian formulation to account for the endocardium motion and we model the cardiac valves by means of the Resistive Immersed Implicit Surface method. To impose a physiological displacement of the domain boundary, we use a 3D cardiac electromechanical model of the left ventricle coupled to a lumped-parameter (0D) closed-loop model of the remaining circulation. We thus obtain a one-way coupled electromechanics-fluid dynamics model in the left ventricle. To extend the left ventricle motion to the endocardium of the left atrium and to that of the ascending aorta, we introduce a preprocessing procedure according to which an harmonic extension of the left ventricle displacement is combined with the motion of the left atrium based on the 0D model. To better match the 3D cardiac fluid flow with the external blood circulation, we couple the 3D Navier-Stokes equations to the 0D circulation model, obtaining a multiscale coupled 3D-0D fluid dynamics model that we solve via a segregated numerical scheme. We carry out numerical simulations for a healthy left heart and we validate our model by showing that meaningful hemodynamic indicators are correctly reproduced.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Modeling heart flow dynamics using numerical simulations to identify the vortex ring: a practical guide

    physics.flu-dyn 2024-11 conditional novelty 4.0 of 10

    A CFD parameter study finds that moving walls, a hyperbolic-tangent inlet profile, a long enough inlet tube, and a mass-flow outlet reliably reproduce the left ventricular vortex ring in simulations.

Pith tools