REVIEW 3 major objections 6 minor 60 references
Coulomb Crystallization of Highly Charged Ni^12+ Ions in a Linear Paul Trap
T0 review · 3 major / 6 minor · reviewed 2026-08-16 · deepseek-v4-flash
Pith's one-line read The paper reports the first Coulomb crystallization of Ni$^{12+}$ highly charged ions, sympathetically cooled from megakelvin to 100 mK by laser-cooled $^9$Be$^+$ in a room-temperature Paul trap.
desk verdict First Coulomb crystallization of Ni12+ in a Paul trap, with an important caveat: the charge-state ID and 100-mK temperature both hang on a tuned MD simulation, so the claim needs an independent check or at least a parameter scan. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing mechanism is sympathetic cooling: laser-cooled $^9$Be$^+$ ions, whose charge-to-mass ratio is close to that of $^{58}$Ni$^{12+}$, share energy with the injected highly charged ions through Coulomb interaction until the whole two-species crystal reaches the 100 mK level. The charge-state assignment is carried by a molecular-dynamics comparison of axial crystal length, in which simulated lengths for Ni$^{11+}$, Ni$^{12+}$, and Ni$^{13+}$ (167.8, 171.9, and 175.8 μm) bracket the measured 171.1 μm. A two-step deceleration chain, from about 700 qV to about 100 qV in a pulsed drift tube and then into the trap raised to about 100 V, is what makes injection of such energetic ions possible.
What would settle it
Re-image the crystal at higher magnification and measure the axial secular-motion frequency or drive the predicted 24 Hz M1 clock transition of the dark ion: a resonance at the Ni$^{12+}$ wavelength would confirm the charge state directly, whereas a null or shifted signal would indicate that the dark ion is not Ni$^{12+}$ and that the simulation-based identification is not decisive.
Extended reading notes
Core claim
The paper reports that $^{58}$Ni$^{12+}$ ions, produced in an electron beam ion trap and selected by time-of-flight charge and isotope filtering, were decelerated from roughly 700 qV to about 100 qV by a pulsed drift tube and electrostatic lens system, injected into a room-temperature linear Paul trap, and sympathetically cooled by an already crystallized ensemble of laser-cooled $^9$Be$^+$ ions. The resulting two-species Coulomb crystal, imaged as nine bright Be$^+$ ions plus one dark ion, has an axial length of 171.1 μm, matching a molecular-dynamics simulation of one Ni$^{12+}$ among nine Be$^+$ (171.9 μm) and not the lengths predicted for Ni$^{11+}$ (167.8 μm) or Ni$^{13+}$ (175.8 μm). From the matched simulation the work extracts a final equilibrium ion temperature at the 100 mK level, seven orders of magnitude below the initial megakelvin kinetic energy.
Load-bearing premise
The identification of the dark ion as Ni$^{12+}$ and its 100 mK temperature rest on molecular-dynamics simulations that assume an 'appropriate random heating force' and a fixed composition of nine Be$^+$ ions plus one dark ion, while the simulated axial lengths for neighboring charge states differ by only about 4 μm, close to the imaging resolution.
Editorial extensions
If this is right
- The same deceleration and sympathetic-cooling protocol can be applied to other EBIT-produced highly charged ions; the paper reports its use for Ni$^{7+}$ through Ni$^{13+}$ and for argon HCIs.
- With Ni$^{12+}$ co-crystallized with Be$^+$, quantum-logic spectroscopy of the predicted 8 mHz E2 clock transition becomes possible, since Be$^+$ can serve as the logic ion.
- The measured crystal length provides a charge-state fingerprint that can validate time-of-flight charge selection in future injection runs.
- At the demonstrated 100 mK temperature and room-temperature vacuum of $3\times10^{-8}$ Pa, the HCI lifetime is limited to tens of seconds, so a cryogenic high-vacuum trap is the direct next step toward clock interrogation.
Reading between the lines
- A direct spectroscopic probe of the dark ion, rather than crystal-length matching alone, would strengthen the Ni$^{12+}$ identification, because the roughly 4 μm spacing between adjacent charge states is comparable to the imaging resolution.
- If the injection and cooling scheme generalizes as the paper suggests, a room-temperature EBIT-Paul-trap beamline could serve as a rapid screening platform for several HCI clock candidates before building a cryogenic clock system.
- The 100 mK temperature is an output of a simulation with a tuned heating force; a model-independent check would be to measure the dark ion's axial secular motion and compare its normal-mode frequency to the simulated value.
- A natural control experiment is to repeat the length-matching procedure with a known contaminant species, as the paper does for BeH$^+$, and verify that the fitted charge state tracks the time-of-flight selection across many injection cycles.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript reports the sympathetic cooling of highly charged nickel ions (58Ni12+) in a room-temperature linear Paul trap using laser-cooled 9Be+ ions. Ni-HCIs are produced in an EBIT, charge- and isotope-selected via time-of-flight with a pulsed electrode plate, decelerated through a pulsed drift tube and electrostatic lens stack, and injected into a Paul trap containing a pre-formed Be+ Coulomb crystal. Fluorescence images show a two-species crystal with a dark ion, and the authors infer both the dark ion's charge state and the crystal temperature by comparing the measured axial crystal length (171.1 µm) with molecular dynamics simulations (171.9 µm for Ni12+, versus 167.8 µm for Ni11+ and 175.8 µm for Ni13+). The simulation, which includes an 'appropriate random heating force' tuned to reproduce the image, yields an equilibrium temperature at the 100 mK level. The conclusion states that two-component Coulomb crystals of Ni12+ and Be+ were formed, with ion temperature reaching 100 mK, marking a step toward a Ni12+-based optical clock.
Significance. If the central claim holds, this is the first demonstration of a cold, crystallized sample of the Ni12+ clock candidate, substantively extending the prior art of sympathetic cooling of highly charged ions beyond the Ar13+ and Xe-HCI demonstrations. The experimental integration of EBIT production, TOF-based isotope/charge selection, pulsed deceleration, and room-temperature trap loading is technically significant and provides a transferable platform for HCI clock work. The paper also honestly identifies the residual-gas charge-exchange lifetime limitation of its room-temperature vacuum, and its MD-simulation comparison approach is a reasonable first-order analysis. However, as detailed in the major comments, the two headline quantitative claims—the Ni12+ charge identification and the 100 mK temperature—currently rest on a single tuned simulation without the error propagation and independent checks that a claim at this level of specificity requires.
major comments (3)
- [§III, Fig. 8] The charge-state identification of the dark ion as Ni12+ is not conclusively established. The experimental axial length of 171.1 µm is quoted without an uncertainty, while the stated imaging uncertainty is ±1.7 µm and the simulated lengths for Ni11+, Ni12+, and Ni13+ are 167.8, 171.9, and 175.8 µm—spacings of only about 4 µm, i.e., roughly twice the imaging resolution. The identification also assumes exactly nine Be+ ions and one dark ion in the simulated crystal. The authors should provide an uncertainty on the measured length, scan the assumed Be+ number and the heating-force amplitude, and ideally confirm the charge state by an independent measurement such as a secular-motion or axial-oscillation frequency, before claiming that the co-cooled species is Ni12+.
- [§III, Fig. 8 and Conclusion] The 100 mK temperature is not an independent experimental result. It is extracted from the same molecular-dynamics simulation that was tuned to reproduce the observed images by introducing an 'appropriate random heating force' whose physical origin and fitted value are not reported. Because the heating force directly controls the steady-state kinetic energy, the inferred temperature is circularly determined by the image match. The manuscript should specify the heating model, its parameters and uncertainties, and provide at least one independent temperature constraint (e.g., Doppler recooling timescale, sideband thermometry, or a separate non-tuned simulation) before the '100 mK level' claim is supported.
- [§III, Fig. 8(b)] The assumed ion composition of exactly nine Be+ ions plus one dark ion is not experimentally justified. The axial crystal length depends strongly on the total ion number, so an incorrect Be+ count would change the inferred charge state. The authors should explain how the Be+ number was determined (for example, from fluorescence intensity or known loading statistics) and show how the inferred charge state varies when the Be+ number is changed by ±1 or ±2 within the simulation.
minor comments (6)
- [Throughout] There are numerous typographical errors, including 'HCls' and 'HCl' for HCIs (e.g., in §III and Fig. 7 caption), and 'we using clear crystallized ion images' in §III; a thorough proofreading pass is needed.
- [Fig. 7 caption] The caption reads 'Coulomb crystal of Be+ and 58HCI12+' but should read 'Be+ and 58Ni12+'; also, the dark circular feature is not clearly marked.
- [§III, Fig. 8 caption] The caption for panel (c) refers to 'BeH⁺' but the text earlier does not define how this species was identified; clarify whether this was a known contaminant or an assumption.
- [§III] The sentence 'we built a double-pass optical path based on AOM to achieve a frequency shift of 1.25 GHz' is incomplete or imprecise: a double-pass AOM shifts by twice the AOM drive frequency, so the drive frequency should be stated.
- [References] Reference [57] is a conference abstract with limited accessibility; if possible, cite a peer-reviewed description of the cold-HCI preparation method.
- [§III] The manuscript states that a Python-based simulation program was developed but provides no code availability or detailed parameter list; making the code or a complete parameter table available would strengthen reproducibility.
Circularity Check
Reported 100 mK ion temperature is read from an MD simulation whose 'appropriate random heating force' was tuned to reproduce the image, so the headline temperature reduces to the fitted model.
-
fitted input called prediction
[Section III, molecular-dynamics simulation paragraph and Fig. 8 temperature extraction]
"By introducing an appropriate random heating force, we generated a series of ion crystal images under different conditions. Comparing the equilibrium-state ion distributions from the simulations with the experimentally observed images enabled us to identify the simulated configurations that best reproduced the experimental results. ... For the temperature, we obtained simulated images that closely matched the experimental results, from the simulation, the temperature evolution curve was extracted, yielding a final equilibrium temperature of 100 mK level."
The 'appropriate random heating force' is a free parameter selected by matching simulated images to the experimental image. The reported 100 mK temperature is then read from the matched simulation rather than measured independently. Within the assumed model, the equilibrium temperature is a dependent variable of this tuned heating force, so the conclusion's claim that the ions reach the 100 mK level is an output of the fitting procedure, not an independently constrained prediction. No calibration of the heating force to a known temperature or exploration of degenerate parameter combinations is reported.
full rationale
The charge-state identification itself is not circular: the paper tests Ni11+, Ni12+, and Ni13+ in a forward model and compares the predicted axial lengths (167.8, 171.9, 175.8 um) with the observed 171.1 um, and it calibrates the simulation against known 3-Be+ and 5-Be+ plus BeH+ crystals. That is a model-comparison argument with independent content. The circular burden is limited to the temperature claim: the same MD simulation is tuned with an 'appropriate random heating force' until its images match the experiment, and then the equilibrium temperature of the tuned simulation (100 mK) is reported as the experimental ion temperature. This is a fitted input called prediction, making the temperature claim partially circular. The self-citations (e.g., Refs. [55], [56], [58]) are methods and background citations and are not load-bearing for the derivation. The paper also honestly notes the short HCI lifetime due to charge exchange, which is a limitation rather than a circularity.
Assumptions & free parameters
free parameters (3)
- Random heating force in MD simulation =
not stated (tuned to match images)
- Number of Be+ ions and one dark ion in simulated crystal =
nine Be+ ions plus one dark ion
- Charge state of the co-cooled dark ion =
12+ (inferred from best match)
assumptions (3)
- domain assumption The molecular dynamics simulation method of Ref. [60] accurately reproduces ion positions and fluorescence images of multispecies Coulomb crystals in a Paul trap.
- domain assumption The extracted and selected ion bunch is pure 58Ni12+ with no other ion species surviving the Wien filter and time-of-flight selection.
- domain assumption The observed crystal is in quasi-equilibrium, so the simulated equilibrium state corresponds to the experimental temperature.
Cite this review
Pith. "Pith review of Coulomb Crystallization of Highly Charged Ni^12+ Ions in a Linear Paul Trap." pith.science (2026). https://pith.science/paper/2YPM5M3I
@misc{pith2026250419182,
author = {Pith},
title = {Pith review of: Coulomb Crystallization of Highly Charged Ni^12+ Ions in a Linear Paul Trap},
year = {2026},
howpublished = {\url{https://pith.science/paper/2YPM5M3I}},
note = {Machine review of arXiv:2504.19182}
}
abstract
Optical clocks have garnered widespread attention due to their unparalleled precision in time-frequency standards, geodetic measurements, and fundamental physics research. Among emerging developments, highly charged ion (HCI)-based optical clocks have attracted significant scientific interest owing to their exceptional resilience against electromagnetic perturbations and enhanced sensitivity to variations in the fine-structure constant ($\alpha$). While the recent successful demonstration of an Ar$^{13+}$ optical clock has validated the feasibility of HCI-based systems, Ni$^{12+}$ -- featuring an ultranarrow clock transition linewidth -- stands out as a superior candidate for achieving HCI optical clocks with $10^{-19}$ level uncertainty and stability. In this work, we report the Coulomb crystallization of nickel highly charged ions (Ni-HCIs). Through a precision deceleration and sympathetic cooling protocol in a room-temperature Paul trap, high-energy Ni-HCI bunches were sympathetically cooled from megakelvin to the 100-millikelvin range using laser-cooled Be$^{+}$ ions. This work represents a pivotal step toward the realization of an optical clock based on the Ni$^{12+}$ ion.
Figures
Reference graph
Works this paper leans on
-
[1]
Y. M. Yu and B. K. Sahoo, Selected Highly Charged Ions as Prospective Candidates for Optical Clocks with Quality Factors Larger than 1015, Phys. Rev. A 97, 041403 (2018)
work page 2018
-
[2]
M. G. Kozlov, M. S. Safronova, J. R. Crespo López-Urrutia, and P. O. Schmidt, Highly Charged Ions: Optical Clocks and Applications in Fundamental Physics, Rev. Mod. Phys. 90, 045005 (2018)
work page 2018
-
[3]
J. C. Berengut, V. A. Dzuba, and V. V Flambaum, Enhanced Laboratory Sensitivity to Variation of the Fine -Structure Constant Using Highly Charged Ions, Phys. Rev. Lett. 105, 120801 (2010)
work page 2010
-
[4]
Y. Yu and B. K. Sahoo, A Hunt for Highly Charged Ions as Ultra-Stable Optical Clock Candidates: Art of the Energy Level -Crossing Approach, ArXiv 2307.14543v1 (2023)
work page Pith review arXiv 2023
-
[5]
Y.-M. Yu, B. K. Sahoo, and B. Suo, Highly Charged Ion (HCI) Clocks: Frontier Candidates for Testing Variation of Fine-Structure Constant, Front. Phys. 11, 1 (2023). 14
work page 2023
-
[6]
N. Huntemann, C. Sanner, B. Lipphardt, C. Tamm, and E. Peik, Single -Ion Atomic Clock with 3×10-18 Systematic Uncertainty, Phys. Rev. Lett. 116, 063001 (2016)
work page 2016
-
[7]
W. F. Mcgrew, X. Zhang, R. J. Fasano, S. A. Schäffer, K. Beloy, D. Nicolodi, R. C. Brown, N. Hinkley, G. Milani, M. Schioppo, T. H. Yoon, and A. D. Ludlow, Atomic Clock Performance Enabling Geodesy below the Centimetre Level , Nature 564, 87 (2018)
work page 2018
-
[8]
S. M. Brewer, J. -S. Chen, A. M. Hankin, E. R. Clements, C. W. Chou, D. J. Wineland, D. B. Hume, and D. R. Leibrandt, 27Al+ Quantum-Logic Clock with a Systematic Uncertainty below 10−18, Phys. Rev. Lett. 123, 033201 (2019)
work page 2019
Show all 60 references
-
[9]
Aeppli, K
A. Aeppli, K. Kim, W. Warfield, M. S. Safronova, and J. Ye, Clock with 8×10 - 19 Systematic Uncertainty, Phys. Rev. Lett. 133, 23401 (2024)
2024
-
[10]
Oelker, R
E. Oelker, R. B. Hutson, C. J. Kennedy, L. Sonderhouse, T. Bothwell, A. Goban, D. Kedar, C. Sanner, J. M. Robinson, G. E. Marti, D. G. Matei, T. Legero, M. Giunta, R. Holzwarth, F. Riehle, U. Sterr, and J. Ye, Demonstration of 4.8×10 −17 Stability at 1 s for Two Independent Op...
2019
-
[11]
Huang, B
Y. Huang, B. Zhang, M. Zeng, Y. Hao, Z. Ma, H. Zhang, H. Guan, Z. Chen, M. Wang, and K. Gao, Liquid-Nitrogen-Cooled Ca+ Optical Clock with Systematic Uncertainty of 3×10-18, Phys. Rev. Appl. 17, 034041 (2022)
2022
-
[12]
Scheidegger and F
S. Scheidegger and F. Merkt, Precision -Spectroscopic Determination of the Binding Energy of a Two- Body Quantum System: The Hydrogen Atom and the Proton-Size Puzzle, Phys. Rev. Lett. 132, 113001 (2024)
2024
-
[13]
Zhiqiang, K
Z. Zhiqiang, K. J. Arnold, R. Kaewuam, and M. D. Barrett, 176Lu+ Clock Comparison at the 10 -18 Level via Correlation Spectroscopy, Sci. Adv. 9, eadg1971 (2023)
2023
-
[14]
Thielking, M
J. Thielking, M. V. Okhapkin, P. Głowacki, D. M. Meier, L. Von Der Wense, B. Seiferle, C. E. Düllmann, P. G. Thirolf, and E. Peik, Laser Spectroscopic Characterization of the Nuclear-Clock Isomer 229mTh, Nature 556, 321 (2018)
2018
-
[15]
Masuda, A
T. Masuda, A. Yoshimi, A. Fujieda, H. Fujimoto, H. Haba, H. Hara, T. Hiraki, H. Kaino, Y. Kasamatsu, S. Kitao, K. Konashi, Y. Miyamoto, K. Okai, S. Okubo, N. Sasao, M. Seto, T. Schumm, Y. Shigekawa, K. Suzuki, S. Stellmer, K. Tamasaku, S. Uetake, M. Watanabe, T. Watanabe, Y. Y...
2019
-
[16]
Yamaguchi, H
A. Yamaguchi, H. Muramatsu, T. Hayashi, N. Yuasa, K. Nakamura, M. Takimoto, H. Haba, K. Konashi, M. Watanabe, H. Kikunaga, K. Maehata, N. Y. Yamasaki, and K. Mitsuda, Energy of the 229Th Nuclear Clock Isomer Determined by Absolute γ -Ray Energy Difference, Phys. Rev. Lett. 123...
2019
-
[17]
Sikorsky, J
T. Sikorsky, J. Geist, D. Hengstler, S. Kempf, L. Gastaldo, C. Enss, C. Mokry, J. Runke, C. E. Düllmann, P. Wobrauschek, K. Beeks, V. Rosecker, J. H. Sterba, G. Kazakov, T. Schumm, and A. Fleischmann, Measurement of the 229Th Isomer Energy with a Magnetic Microcalorimeter, Phy...
2020
-
[18]
Von Der Wense, B
L. Von Der Wense, B. Seiferle, M. Laatiaoui, J. B. Neumayr, H. J. Maier, H. F. Wirth, C. Mokry, J. Runke, K. Eberhardt, C. E. Düllmann, N. G. Trautmann, and P. G. Thirolf, Direct Detection of the 229Th Nuclear Clock Transition, Nature 533, 47 (2016)
2016
-
[19]
Kraemer, J
S. Kraemer, J. Moens, M. Athanasakis- Kaklamanakis, S. Bara, K. Beeks, P. Chhetri, K. Chrysalidis, A. Claessens, T. E. Cocolios, J. G. M. Correia, H. De Witte, R. Ferrer, S. Geldhof, R. Heinke, N. Hosseini, M. Huyse, U. Köster, Y. Kudryavtsev, M. Laatiaoui, R. Lica, G. Magchie...
2023
-
[20]
Elwell, C
R. Elwell, C. Schneider, J. Jeet, J. E. S. Terhune, H. W. T. Morgan, A. N. Alexandrova, H. B. Tran Tan, A. Derevianko, and E. R. Hudson, Laser Excitation of the 229Th Nuclear Isomeric Transition in a Solid-State Host, Phys. Rev. Lett. 133, 13201 (2024)
2024
-
[21]
Zhang, T
C. Zhang, T. Ooi, J. S. Higgins, J. F. Doyle, L. von der Wense, K. Beeks, A. Leitner, G. A. Kazakov, P. Li, P. G. Thirolf, T. Schumm, and J. Ye, Frequency Ratio of the 229mTh Nuclear Isomeric Transition and the 87Sr Atomic Clock , Nature 633, 63 (2024)
2024
-
[22]
Yamaguchi, Y
A. Yamaguchi, Y. Shigekawa, H. Haba, H. Kikunaga, K. Shirasaki, M. Wada, and H. Katori, Laser Spectroscopy of Triply Charged 229Th Isomer for a Nuclear Clock, Nature 629, 62 (2024)
2024
-
[23]
Tiedau, M
J. Tiedau, M. V. Okhapkin, K. Zhang, J. Thielking, G. Zitzer, E. Peik, F. Schaden, T. Pronebner, I. Morawetz, L. T. De Col, F. Schneider, A. Leitner, M. Pressler, G. A. Kazakov, K. Beeks, T. Sikorsky, and T. Schumm, Laser Excitation of the Th-229 Nucleus, Phys. Rev. Lett. 132,...
2024
-
[24]
Zhang, L
C. Zhang, L. von der Wense, J. F. Doyle, J. S. Higgins, T. Ooi, H. U. Friebel, J. Ye, R. Elwell, J. E. S. Terhune, H. W. T. Morgan, A. N. Alexandrova, H. B. Tran Tan, A. Derevianko, and E. R. Hudson, 229ThF4 Thin Films for Solid- State Nuclear Clocks, Nature 636, 603 (2024)
2024
-
[25]
Hiraki, K
T. Hiraki, K. Okai, M. Bartokos, K. Beeks, H. Fujimoto, Y. Fukunaga, H. Haba, Y. Kasamatsu, S. Kitao, A. Leitner, T. Masuda, M. Guan, N. Nagasawa, R. Ogake, M. Pimon, M. Pressler, N. Sasao, F. Schaden, T. Schumm, M. Seto, Y. Shigekawa, K. Shimizu, T. Sikorsky, K. Tamasaku, S. ...
2024
-
[26]
Draganić, J
I. Draganić, J. R. Crespo López-Urrutia, R. DuBois, S. Fritzsche, V. M. Shabaev, R. S. Orts, I. I. Tupitsyn, Y. Zou, and J. Ullrich, High Precision Wavelength Measurements of QED -Sensitive Forbidden Transitions in Highly Charged Argon Ions, Phys. Rev. Lett. 91, 183001 (2003)
2003
-
[27]
Mäckel, R
V. Mäckel, R. Klawitter, G. Brenner, J. R. Crespo López-Urrutia, and J. Ullrich, Laser Spectroscopy on Forbidden Transitions in Trapped Highly Charged Ar 13+, 16 Phys. Rev. Lett. 107, 143002 (2011)
2011
-
[28]
A. Egl, I. Arapoglou, M. Höcker, K. König, T. Ratajczyk, T. Sailer, B. Tu, A. Weigel, K. Blaum, W. Nörtershäuser, and S. Sturm, Application of the Continuous Stern- Gerlach Effect for Laser Spectroscopy of the 40Ar13+ Fine Structure in a Penning Trap, Phys. Rev. Lett. 123, 123...
2019
-
[29]
Leopold, S
T. Leopold, S. A. King, P. Micke, A. Bautista-Salvador, J. C. Heip, C. Ospelkaus, J. R. Crespo López -Urrutia, and P. O. Schmidt, A Cryogenic Radio- Frequency Ion Trap for Quantum Logic Spectroscopy of Highly Charged Ions , Rev. Sci. Instrum. 90, 073201 (2019)
2019
-
[30]
Micke, J
P. Micke, J. Stark, S. A. King, T. Leopold, T. Pfeifer, L. Schmöger, M. Schwarz, L. J. Spieß, P. O. Schmidt, and J. R. Crespo López-Urrutia, Closed-Cycle, Low- Vibration 4 K Cryostat for Ion Traps and Other Applications, Rev. Sci. Instrum. 90, 065104 (2019)
2019
-
[31]
Schmöger, O
L. Schmöger, O. O. Versolato, M. Schwarz, M. Kohnen, A. Windberger, B. Piest, S. Feuchtenbeiner, J. Pedregosa-Gutierrez, T. Leopold, P. Micke, A. K. Hansen, T. M. Baumann, M. Drewsen, J. Ullrich, P. O. Schmidt, and J. R. C. López - Urrutia, Coulomb Crystallization of Highly Ch...
2015
-
[32]
E. A. Dijck, C. Warnecke, M. Wehrheim, R. B. Henninger, J. Eff, K. Georgiou, A. Graf, S. Kokh, L. P. Kozhiparambil Sajith, C. Mayo, V. M. Schäfer, C. Volk, P. O. Schmidt, T. Pfeifer, and J. R. Crespo López -Urrutia, Sympathetically Cooled Highly Charged Ions in a Radio-Frequen...
2023
-
[33]
Micke, T
P. Micke, T. Leopold, S. A. King, E. Benkler, L. J. Spieß, L. Schmöger, M. Schwarz, J. R. Crespo López- Urrutia, and P. O. Schmidt, Coherent Laser Spectroscopy of Highly Charged Ions Using Quantum Logic , Nature 578 , 60 (2020)
2020
-
[34]
S. A. King, L. J. Spieß, P. Micke, A. Wilzewski, T. Leopold, E. Benkler, R. Lange, N. Huntemann, A. Surzhykov, V. A. Yerokhin, J. R. Crespo López - Urrutia, and P. O. Schmidt, An Optical Atomic Clock Based on a Highly Charged Ion, Nature 611, 43 (2022)
2022
-
[35]
S. G. Porsev, U. I. Safronova, M. S. Safronova, P. O. Schmidt, A. I. Bondarev, M. G. Kozlov, I. I. Tupitsyn, and C. Cheung, Optical Clocks Based on the Cf 15+ and Cf17+ Ions, Phys. Rev. A 102, 012802 (2020)
2020
-
[36]
V. A. Dzuba, V. V Flambaum, and H. Katori, Optical Clock Sensitive to Variations of the Fine-Structure Constant Based on the Ho14+ Ion, Phys. Rev. A 91, 022119 (2015)
2015
-
[37]
J. C. Berengut, V. A. Dzuba, V. V. Flambaum, and A. Ong, Electron -Hole Transitions in Multiply Charged Ions for Precision Laser Spectroscopy and Searching for Variations in α, Phys. Rev. Lett. 106, 210802 (2011)
2011
-
[38]
Cheung, M
C. Cheung, M. S. Safronova, S. G. Porsev, M. G. Kozlov, I. I. Tupitsyn, and A. I. Bondarev, Accurate Prediction of Clock Transitions in a Highly Charged Ion with Complex Electronic Structure, Phys. Rev. Lett. 124, 163001 (2020)
2020
-
[39]
S. G. Porsev, C. Cheung, M. S. Safronova, H. Bekker, N.- H. Rehbehn, J. R. C. 17 López-Urrutia, and S. M. Brewer, Pr 10+as a Candidate for a High- Accuracy Optical Clock for Tests of Fundamental Physics , Phys. Rev. A 110, 042823 (2024)
2024
-
[40]
J. C. Berengut, V. A. Dzuba, V. V Flambaum, and A. Ong, Optical Transitions in Highly Charged Californium Ions with High Sensitivity to Variation of the Fine-Structure Constant, Phys. Rev. Lett. 109, 070802 (2012)
2012
-
[41]
V. I. Yudin, A. V. Taichenachev, and A. Derevianko, Magnetic -Dipole Transitions in Highly Charged Ions as a Basis of Ultraprecise Optical Clocks , Phys. Rev. Lett. 113, 233003 (2014)
2014
-
[42]
Y. Yu, D. Pan, S. Chen, B. Arora, H. Guan, K. Gao, and J. Chen, Atoms Atomic Structure of Nd9+ for Highly Charged Ion Clocks, Atoms 10, 123 (2022)
2022
-
[43]
Yu and B
Y. Yu and B. K. Sahoo, Scrutinizing Al -like 51V10+, 53Cr11+, 55Mn12+, 57Fe13+, 59Co14+, 61Ni15+,and 63Cu16+ Ions for Atomic , Phys. Rev. A 94, 062502 (2016)
2016
-
[44]
V. A. Dzuba, A. Derevianko, and V. V. Flambaum, Ion Clock and Search for the Variation of the Fine-Structure Constant Using Optical Transitions in Nd 13+ and Sm15+, Phys. Rev. A 86, 054502 (2012)
2012
-
[45]
S. O. Allehabi, S. M. Brewer, V. A. Dzuba, V. V. Flambaum, and K. Beloy, High-Accuracy Optical Clocks Based on Group- 16-like Highly Charged Ions , Phys. Rev. A 106, 043101 (2022)
2022
-
[46]
C. Lyu, C. H. Keitel, and Z. Harman, Ultrastable and Ultra -Accurate Clock Transitions in Open-Shell Highly Charged Ions, Commun. Phys. 8, 3 (2025)
2025
-
[47]
Bekker, A
H. Bekker, A. Borschevsky, Z. Harman, C. H. Keitel, T. Pfeifer, P. O. Schmidt, J. R. Crespo López-Urrutia, and J. C. Berengut, Detection of the 5p – 4f Orbital Crossing and Its Optical Clock Transition in Pr 9+, Nat. Commun. 10, 5651 (2019)
2019
-
[48]
Liang, T.-X
S.-Y. Liang, T.-X. Zhang, H. Guan, Q.-F. Lu, J. Xiao, S.-L. Chen, Y. Huang, Y.- H. Zhang, C.-B. Li, Y.-M. Zou, J.-G. Li, Z.-C. Yan, A. Derevianko, M.-S. Zhan, T.-Y. Shi, and K.-L. Gao, Probing Multiple Electric-Dipole-Forbidden Optical Transitions in Highly Charged Nickel Ions...
2021
-
[49]
Windberger, J
A. Windberger, J. R. Crespo López -Urrutia, H. Bekker, N. S. Oreshkina, J. C. Berengut, V. Bock, A. Borschevsky, V. A. Dzuba, E. Eliav, Z. Harman, U. Kaldor, S. Kaul, U. I. Safronova, V. V. Flambaum, C. H. Keitel, P. O. Schmidt, J. Ullrich, and O. O. V ersolato, Identification...
2015
-
[50]
Cheung, S
C. Cheung, S. G. Porsev, D. Filin, M. S. Safronova, M. Wehrheim, L. J. Spieß, S. Chen, A. Wilzewski, J. R. C. López -Urrutia, and P. O. Schmidt, Finding the Ultra-Narrow 3P2 to 3P0 Electric Quadrupole Transition in Ni 12+ Ion for an Optical Clock, Arxiv 2502.05386 (2025)
2025 arXiv
-
[51]
Zhang, C
T. Zhang, C. Li, and T. Shi, Hyperfine- Induced Frequency Shifts for the Candidate Clock Transitions in the 61Ni12+ Ion, Phys. Rev. A 110, 032801 (2024)
2024
-
[52]
C. J. Campbell, A. G. Radnaev, and A. Kuzmich, Wigner Crystals of 229Th for Optical Excitation of the Nuclear Isomer, Phys. Rev. Lett. 106, 223001 (2011)
2011
-
[53]
Kwapień, U
T. Kwapień, U. Eichmann, and W. Sandner, Sympathetic Cooling of Laser - 18 Produced Doubly Charged Ions in a Few-Ion Crystal, Phys. Rev. A 75, 063418 (2007)
2007
-
[54]
Zitzer, J
G. Zitzer, J. Tiedau, M. V. Okhapkin, K. Zhang, C. Mokry, J. Runke, C. E. Düllmann, and E. Peik, Sympathetic Cooling of Trapped Th3+ Alpha-Recoil Ions for Laser Spectroscopy, Phys. Rev. A 109, 033116 (2024)
2024
-
[55]
Liang, Q
S. Liang, Q. Lu, X. Wang, Y. Yang, K. Yao, Y. Shen, B. Wei, J. Xiao, S. Chen, P. Zhou, W. Sun, Y. Zhang, Y. Huang, H. Guan, X. Tong, C. Li, Y. Zou, T. Shi, and K. Gao, A Low-Energy Compact Shanghai-Wuhan Electron Beam Ion Trap for Extraction of Highly Charged Ions, Rev. Sci. I...
2019
-
[56]
S. Chen, Z. Zhou, J. Li, T. Zhang, C. Li, T. Shi, Y. Huang, K. Gao, and H. Guan, Precision Measurement of M1 Optical Clock Transition in Ni 12+, Phys. Rev. Res. 6, 13030 (2024)
2024
-
[57]
S. Chen, Z. Zhou, Y. Huang, H. Guan, and K. Gao, Preparation of Cold Highly Charged Ions in an Ion Trap, in The 4th Conference on Cluster Science and Atomic Manufacturing (2023), p. 65
2023
-
[58]
Z. Zhou, S. Liang, S. Chen, P. Zhou, W. Sun, J. Xiao, Y. Huang, H. Guan, and K. Gao, Deceleration of Highly Charged Ni Ions with Compressed Longitudinal Kinetic Energy Distribution by a Falling Potential, AIP Adv. 12, 035220 (2022)
2022
-
[59]
L.-J. Du, T. Chen, H.-F. Song, S.-L. Chen, H.-X. Li, Y. Huang, X. Tong, K.- L. Gao, and H. Guan, Compensating for Excess Micromotion of Ion Crystals , Chinese Phys. B 24, 083702 (2015)
2015
-
[60]
C. B. Zhang, D. Offenberg, B. Roth, M. A. Wilson, and S. Schiller, Molecular - Dynamics Simulations of Cold Single -Species and Multispecies Ion Ensembles in a Linear Paul Trap, Phys. Rev. A 76, 012719 (2007)
2007
Reviewed August 16, 2026 · model on record in the stance chip above.