Pith. sign in

REVIEW 3 cited by

The Submillimeter Array Polarimeter

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 0807.2255 v1 pith:3JERGW67 submitted 2008-07-14 astro-ph

classification astro-ph
keywords platespolarizationantennapolarimeterwavearraybeencross-polarization
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We describe the Submillimeter Array (SMA) Polarimeter, a polarization converter and feed multiplexer installed on the SMA. The polarimeter uses narrow-band quarter-wave plates to generate circular polarization sensitivity from the linearly-polarized SMA feeds. The wave plates are mounted in rotation stages under computer control so that the polarization handedness of each antenna is rapidly selectable. Positioning of the wave plates is found to be highly repeatable, better than 0.2 degrees. Although only a single polarization is detected at any time, all four cross correlations of left- and right-circular polarization are efficiently sampled on each baseline through coordinated switching of the antenna polarizations in Walsh function patterns. The initial set of anti-reflection coated quartz and sapphire wave plates allows polarimetry near 345 GHz; these plates have been have been used in observations between 325 and 350 GHz. The frequency-dependent cross-polarization of each antenna, largely due to the variation with frequency of the retardation phase of the single-element wave plates, can be measured precisely through observations of bright point sources. Such measurements indicate that the cross-polarization of each antenna is a few percent or smaller and stable, consistent with the expected frequency dependence and very small alignment errors. The polarimeter is now available for general use as a facility instrument of the SMA.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. OpenAlex reports about 44 citations worldwide. Full citation record

  1. Tracking down the broadband polarimetric properties of PG 1553+113

    astro-ph.HE 2026-05 unverdicted novelty 4.0 of 10

    New IXPE X-ray polarimetry and optical monitoring of PG 1553+113 reveal variable polarization and a large EVPA swing, supporting jet models with related but non-co-spatial X-ray and optical emission regions.

  2. IXPE Observations of the Blazar Mrk 501 in 2022: A Multiwavelength View

    astro-ph.HE 2025-07 conditional novelty 4.0 of 10

    IXPE's third 2022 observation of Mrk 501 yields X-ray polarization degree 6±2% at angle 143±11°, consistent with earlier epochs and with shock-based jet models.

  3. Measuring Magnetic Field Strengths in Galactic Star-forming Regions via the Zeeman Effect with the SKA

    astro-ph.GA 2026-06 unverdicted novelty 2.0 of 10

    The paper presents predictions and observational plans for Zeeman effect measurements with SKA to provide statistical data on magnetic field strengths across scales in molecular clouds.

Pith tools