A compensated multi-gap RPC with 2 m-long strips for the LEPS2 experiment
classification
⚛️ physics.ins-det
keywords
chamberscorrectiondetectorexperimentleps2multi-gapslewingstrips
read the original abstract
We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in a mirrored configuration. A time resolution of sigma ~ 80 ps was achieved for any position within a strip (at above 99% detection efficiency); after performing the time-charge slewing correction, this value could be reduced to 60 ps. A link between the small contribution of the slewing correction to timing and the suppression of modal dispersion in the detector could be established.
This paper has not been read by Pith yet.
discussion (0)