REVIEW 4 major objections 6 minor 228 references
Review: Adaptive Radiation Therapy for Head and Neck Cancer
T0 review · 4 major / 6 minor · reviewed 2026-08-06 · deepseek-v4-flash
Pith's one-line read The review argues that adaptive radiotherapy for head and neck cancer is entering an imaging-biomarker era, and that a standardized validation framework—beginning with a Delphi consensus study—is needed before these tools can guide…
desk verdict A useful narrative review and trial compilation whose forward-looking 'must adapt now' framing outruns the evidence it itself cites; worth serious peer review. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing proposal is a structured validation framework for imaging biomarkers: a Delphi consensus study intended to produce the IB-IDEAL initiative, a harmonized development pathway for imaging biomarkers specific to radiation oncology. The paper also surveys the technical enablers—MRI-guided linear accelerators, PET-guided radiotherapy delivery, AI-based auto-segmentation, synthetic CT generation, and multiparametric MRI methods such as diffusion-weighted imaging, dynamic contrast enhancement, and MR fingerprinting—and treats them as components that this framework would standardize and validate. The argument is carried by the claim that these components are individually promising but collectively uncoordinated, and that a consensus-based evaluation pathway is the missing link.
What would settle it
A prospective multicenter trial in which mid-treatment imaging biomarkers (for example, a measured change in apparent diffusion coefficient at week three) are used to trigger replanning, compared against standard weekly replanning, would settle the claim: if the biomarker-guided arm shows no improvement in locoregional control or patient-reported toxicity, or if the biomarker cannot be measured reproducibly across centers with the recommended protocols, the paper's central recommendation loses its empirical basis.
Extended reading notes
Core claim
On the paper's own terms, adaptive radiation therapy for head and neck cancer is nearing a transition: technical platforms now exist that can both measure biological change and act on it, but the field lacks the shared standards to turn that capability into reliable clinical decisions. The review's central claim is that imaging biomarkers—apparent diffusion coefficient, dynamic contrast enhancement, tissue relaxometry, oxygen-sensitive signals, and MR fingerprinting—can inform when and how to adapt treatment, and that new delivery systems such as MRI-guided linear accelerators and PET-guided radiotherapy should be used to respond to those signals in near real time. Because the current evidence base contains only one completed phase III randomized trial of ART, which did not show significant differences in primary endpoints, the paper does not argue for one optimal implementation; instead it argues for coordinated standardization, starting with a Delphi consensus study that would produce a harmonized development pathway for imaging biomarkers (proposed as IB-IDEAL). The goal is to close the translational gap between research tools and routine patient care, and to make adaptation a biology-driven rather than schedule-driven intervention.
Load-bearing premise
The recommendations depend on the assumption that imaging biomarkers such as apparent diffusion coefficient, dynamic contrast enhancement, and MR fingerprinting can be validated and translated into adaptive-treatment decisions; this is not established by the cited evidence, which includes only a single completed phase III randomized trial of ART and it showed no significant difference in primary endpoints.
Editorial extensions
If this is right
- If imaging biomarkers are validated, adaptive plans can be triggered by measured tumor response rather than by fixed weekly schedules, potentially concentrating dose where it is needed.
- A harmonized framework like the proposed Delphi-based IB-IDEAL would give the field shared terminology and reporting standards, making independent studies comparable and enabling credible multi-center trials.
- MR-guided and PET-guided treatment systems could act on biomarker signals in near real time, shifting adaptation from offline replanning to online, even intra-fraction, adjustment.
- NTCP-aware adaptation, in which replanning is triggered by predicted normal-tissue complication risks, would combine with biomarker information to personalize both dose and timing.
- If the framework is adopted, the evidence base can move beyond the single completed phase III trial (which did not show a significant difference in primary endpoints) toward trials in which the right patients receive the right adaptation at the right time.
Reading between the lines
- A natural extension is that the inconclusive first phase III trial might be reinterpreted: if biomarkers identify patients whose anatomy is changing in a way that adaptation would help, the benefit of ART may be real but hidden in unselected populations, and a biomarker-stratified trial would test this directly.
- A biological-extension inference is that the proposed consensus process would need to specify not only how biomarkers are reported but also how they gain regulatory clearance, a step the review touches on but does not resolve.
- A testable near-term extension would be to use the reported week-three ADC change (with an area under the curve near 0.83 for predicting local recurrence) as the trigger for a prospective adaptive trial, with validation thresholds fixed before enrollment.
- If imaging biomarkers fail external validation, the fallback may be purely dosimetric adaptation using NTCP thresholds, which is already supported by retrospective data; the biomarker program would then remain a research tool rather than a clinical driver.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript is a narrative review of adaptive radiation therapy (ART) for head and neck cancer (HNC), covering current IGRT platforms (Halcyon, CT-on-Rails, Ethos, MR-Linac), AI-based contouring, emerging PET-guided and MR-based imaging biomarkers (DWI/ADC, DCE, CEST, T1rho, BOLD, ASL/IVIM, SyntheticMR, MRF), and decision-support concepts such as NTCP-aware ART, Markov decision processes, and digital twins. The authors argue that ART for HNC is entering a new era in which imaging biomarkers and new technologies should be integrated into clinical workflows, and they recommend a structured consensus framework (a Delphi study and an 'IB-IDEAL' initiative) to standardize biomarker development and validation in radiation oncology.
Significance. If its forward-looking claims are appropriately tempered, this review would be a useful synthesis for medical physicists, radiation oncologists, and trialists planning ART biomarker studies. Its strengths are breadth and currency: it gathers recent device-specific experience, summarizes quantitative MRI techniques relevant to HNC, and clearly identifies the gap between technical availability of imaging biomarkers and their validated clinical integration. The paper also gives appropriate attention to quality assurance, clinical trial frameworks (R-IDEAL, DECIDE-AI, QIBA), and the need for interdisciplinary collaboration. The main weakness is that the review's central recommendation is stated more strongly than the evidence it cites supports, and several presentation issues (notably in Table 1) undermine its reliability as a reference summary.
major comments (4)
- [§1 and §5] The central claim that imaging biomarkers 'must be addressed now' for ART patient impact (§1) and the call for an 'IB-IDEAL' consensus framework (§5) are not supported by the evidence the review itself presents. The only completed phase III ART RCT (ARTIX, ref 10) reported no significant differences in primary or secondary endpoints except parotid excretory function, and the biomarker evidence is dominated by small single-center, retrospective, or preprint studies (e.g., refs 102-104, 158-160). The 'prospective validation' of ADC in ref 102 is a preprint, BOLD results are described as 'inconsistent' (§4.2), and IVIM on the MR-Linac showed 'low correlations' (§4.3). Please reframe the conclusion as a research and standardization agenda, with explicit statements about evidence maturity, rather than as a directive for clinical adoption of these biomarkers.
- [Table 1] Table 1 contains multiple impossible entries in the 'Enrollment Start Date' column, such as '41 Dec 2009', '74 Sep 2010', '100 Aug 2011', '0 Nov 2015', '472 May 2018', and '0 Dec 2024'. These appear to result from merging enrollment numbers or other fields with the start date. Since Table 1 is a central reference summary of the trial landscape, please re-extract each row from ClinicalTrials.gov and correct the column, and verify trial phase and status labels against the source records (e.g., NCT01124409 is listed as Phase 3).
- [§3.2] The motion statistics quoted for the upper airway of HNC patients (motion greater than 5 mm and 10 mm seen in 13% and 4% of intrafraction imaging time) are attributed to ref 96, which is a study of esophageal motion, not head-and-neck upper-airway motion. This mis-citation weakens the case for real-time motion monitoring on the MR-Linac. Please either replace the citation with HNC-specific cine MRI data (e.g., refs 97-98) or rephrase the claim to reflect the actual study population.
- [§5] The statement that 'organizations like RSNA shift their focus, including a move away from QIBA initiatives' is asserted without a citation, and it is part of the rationale for proposing the new IB-IDEAL framework. Please add a verifiable source for this claim or qualify it as the authors' opinion. In addition, if IB-IDEAL is intended as a concrete proposal, the review should define its scope, stakeholders, and relationship to existing frameworks (R-IDEAL, DECIDE-AI, QIBA) rather than naming it only in the final paragraph.
minor comments (6)
- [§2.2.2] The sentence 'Although cone-beam CT (CBCT) is commonly used for patient setup due to its integration into radiotherapy systems and the ability to perform imaging directly in the treatment position...' is duplicated; please delete the repeated sentence.
- [§2.2.4] The text 'developed by Elekta and Phillips' should be 'developed by Elekta and Philips'.
- [§4.3] The word 'redout' should be 'readout' in the description of arterial spin labeling.
- [§4.4.2] The phrase 'On of the most exciting recent expansions' should be 'One of the most exciting recent expansions'.
- [Table 1] The row for NCT05996432 lists the primary outcome as 'Imaging biomarkers' but the summary says 'Use of MRI for identifying radioresistence'; 'radioresistence' should be 'radioresistance'.
- [References] Several references to the Journal of Magnetic Resonance Imaging are listed with the journal title 'Magnetic Resonance Imaging' (e.g., refs 159-160), which is a different journal; please standardize the journal names across the reference list.
Circularity Check
No significant circularity: the paper is a narrative review that makes no derived predictions; its self-citations are evidentiary rather than load-bearing.
full rationale
This manuscript is a narrative review of adaptive radiation therapy (ART) for head and neck cancer, not a derivation of new quantitative results. It contains no fitted parameters, no equations whose outputs are defined by their inputs, and no prediction that is statistically forced by a prior fit. The paper's central call for imaging-biomarker validation and for a structured consensus framework ('IB-IDEAL') is presented explicitly as a proposal and a research need rather than as a result derived from data. Its statements about biomarker performance are literature summaries, and where those summaries rely on the authors' own prior work or preprints, the citations point to external studies (e.g., refs 102, 103, 196-198, 213) that are not outputs of the present review and are not used to define the review's conclusions. The self-citation in the proposed framework lineage (R-IDEAL, ref 32, with a co-author overlap) is used as an example of an existing evaluation framework, not as an authority that forecloses alternatives. The paper even disclaims providing a single correct answer in its abstract and conclusion. Thus no step in the paper reduces by construction to its own inputs, and the review's forward-looking recommendations, however contestable on evidence-maturity grounds, are not circular.
Assumptions & free parameters
assumptions (3)
- domain assumption Imaging biomarkers (ADC, DCE, MRF, etc.) will eventually be validated and improve ART decision making.
- domain assumption RSNA is moving away from QIBA initiatives, creating a leadership gap in imaging biomarkers for radiation oncology.
- domain assumption The cited literature is accurately interpreted and representative of the field.
invented entities (1)
-
IB-IDEAL initiative
Cite this review
Pith. "Pith review of Review: Adaptive Radiation Therapy for Head and Neck Cancer." pith.science (2026). https://pith.science/paper/76MIY37G
@misc{pith2026250800651,
author = {Pith},
title = {Pith review of: Review: Adaptive Radiation Therapy for Head and Neck Cancer},
year = {2026},
howpublished = {\url{https://pith.science/paper/76MIY37G}},
note = {Machine review of arXiv:2508.00651}
}
read the original abstract
The future of ART in head and neck cancer is just beginning. Novel technologies have pushed the boundary of what is possible in terms of techniques to identify biomarkers for adaptation as well as innovative devices specialized to respond to these adaptations, sometimes in real-time. Important interdisciplinary steps must be taken moving forward to ensure the safe deployment of these new techniques, such as rigorous quality assurance evaluations from medical physicists, clinical trials from physicians, and comprehensive testing from vendors prior to release. In summary, we aimed not to provide a single correct answer for the optimal implementation of ART in the era of imaging biomarkers, but to encourage the field to collaborate and bring each idea discussed here together to overcome current barriers and deliver the best treatment possible to the patient.
Reference graph
Works this paper leans on
-
[1]
Nuyts S, Bollen H, Eisbruch A, et al. Adaptive radiotherapy for head and neck cancer: Pitfalls and possibilities from the radiation oncologist’s point of view. Cancer Medicine. 2024;13(8):e7192. doi:10.1002/cam4.7192
-
[2]
Maheshwari G, Dhanawat A, Kumar HS, Sharma N, Jakhar SL. Clinical and dosimetric impact of adaptive intensity-modulated radiotherapy in locally advanced head-and- neck cancer. Journal of Cancer Research and Therapeutics. 2020;16(3):600-604. doi:10.4103/jcrt.JCRT_928_19
-
[3]
In silico evaluation and feasibility of near margin- less head and neck daily adaptive radiotherapy
Dohopolski M, Visak J, Choi B, et al. In silico evaluation and feasibility of near margin- less head and neck daily adaptive radiotherapy. Radiotherapy and Oncology. 2024;197:110178. doi:10.1016/j.radonc.2024.110178
arXiv 2024
-
[4]
In Silico Analysis of Adjuvant Head and Neck Online Adaptive Radiation Therapy
All S, Zhong X, Choi B, et al. In Silico Analysis of Adjuvant Head and Neck Online Adaptive Radiation Therapy. Advances in Radiation Oncology. 2024;9(1):101319. doi:10.1016/j.adro.2023.101319
arXiv 2024
-
[5]
Yang H, Hu W, Wang W, Chen P, Ding W, Luo W. Replanning During Intensity Modulated Radiation Therapy Improved Quality of Life in Patients With Nasopharyngeal Carcinoma. International Journal of Radiation Oncology*Biology*Physics. 2013;85(1):e47-e54. doi:10.1016/j.ijrobp.2012.09.033
-
[6]
Burns PB, Rohrich RJ, Chung KC. The Levels of Evidence and Their Role in Evidence- Based Medicine: Plastic and Reconstructive Surgery. 2011;128(1):305-310. doi:10.1097/PRS.0b013e318219c171
-
[7]
De Bruycker A, De Neve W, Daisne JF, et al. Disease Control and Late Toxicity in Adaptive Dose Painting by Numbers Versus Nonadaptive Radiation Therapy for Head and Neck Cancer: A Randomized Controlled Phase 2 Trial. International Journal of Radiation Oncology*Biology*Physics. 2024;120(2):516-527. doi:10.1016/j.ijrobp.2024.01.012 30
-
[8]
Adaptive Dose Painting by Numbers for Head-and-Neck Cancer
Duprez F, De Neve W, De Gersem W, Coghe M, Madani I. Adaptive Dose Painting by Numbers for Head-and-Neck Cancer. International Journal of Radiation Oncology*Biology*Physics. 2011;80(4):1045-1055. doi:10.1016/j.ijrobp.2010.03.028
Show all 228 references
-
[9]
Ghosh Laskar S, Sinha S, Kumar A, et al. Reducing Salivary Toxicity with Adaptive Radiotherapy (ReSTART): A Randomized Controlled Trial Comparing Conventional IMRT to Adaptive IMRT in Head and Neck Squamous Cell Carcinomas. Clinical Oncology. 2024;36(6):353-361. doi:10.1016/j....
2024 doi
-
[10]
Weekly Adaptive Radiotherapy vs Standard Intensity-Modulated Radiotherapy for Improving Salivary Function in Patients With Head and Neck Cancer: A Phase 3 Randomized Clinical Trial
Castelli J, Thariat J, Benezery K, et al. Weekly Adaptive Radiotherapy vs Standard Intensity-Modulated Radiotherapy for Improving Salivary Function in Patients With Head and Neck Cancer: A Phase 3 Randomized Clinical Trial. JAMA Oncol. 2023;9(8):1056. doi:10.1001/jamaoncol.2023.1352
2023
-
[11]
Maximum tolerated dose in a phase I trial on adaptive dose painting by numbers for head and neck cancer
Madani I, Duprez F, Boterberg T, et al. Maximum tolerated dose in a phase I trial on adaptive dose painting by numbers for head and neck cancer. Radiotherapy and Oncology. 2011;101(3):351-355. doi:10.1016/j.radonc.2011.06.020
2011 doi
-
[12]
Ding Y, Mohamed ASR, Yang J, et al. Prospective observer and software-based assessment of magnetic resonance imaging quality in head and neck cancer: Should standard positioning and immobilization be required for radiation therapy applications? Practical Radiation Oncology. 20...
2015 doi
-
[13]
Early 18F-FDG-PET Response During Radiation Therapy for HPV-Related Oropharyngeal Cancer May Predict Disease Recurrence
Mowery YM, Vergalasova I, Rushing CN, et al. Early 18F-FDG-PET Response During Radiation Therapy for HPV-Related Oropharyngeal Cancer May Predict Disease Recurrence. Int J Radiat Oncol Biol Phys. 2020;108(4):969-976. doi:10.1016/j.ijrobp.2020.08.029
2020 doi
-
[14]
Heukelom J, Hamming O, Bartelink H, et al. Adaptive and innovative Radiation Treatment FOR improving Cancer treatment outcomE (ARTFORCE); a randomized controlled phase II trial for individualized treatment of head and neck cancer. BMC Cancer. 2013;13:84. doi:10.1186/1471-2407-13-84
2013 doi
-
[15]
A Phase II Trial Evaluating Rapid Mid-Treatment Nodal Shrinkage to Select for Adaptive Deescalation in p16+ Oropharyngeal Cancer Patients Undergoing Definitive Chemoradiation
Kim JK, Tam M, Karp JM, et al. A Phase II Trial Evaluating Rapid Mid-Treatment Nodal Shrinkage to Select for Adaptive Deescalation in p16+ Oropharyngeal Cancer Patients Undergoing Definitive Chemoradiation. International Journal of Radiation Oncology*Biology*Physics. 2023;117(...
2023 doi
-
[16]
Adaptive FDG-PET/CT guided dose escalation in head and neck squamous cell carcinoma: Late toxicity and oncologic outcomes (The ADMIRE study)
Al-Mamgani A, Kessels R, Gouw ZAR, et al. Adaptive FDG-PET/CT guided dose escalation in head and neck squamous cell carcinoma: Late toxicity and oncologic outcomes (The ADMIRE study). Clin Transl Radiat Oncol. 2023;43:100676. doi:10.1016/j.ctro.2023.100676 31
2023
-
[17]
Longitudinal assessment of diffusion-weighted imaging during magnetic resonance-guided radiotherapy in head and neck cancer
Boeke S, Habrich J, Kübler S, et al. Longitudinal assessment of diffusion-weighted imaging during magnetic resonance-guided radiotherapy in head and neck cancer. Radiat Oncol. 2025;20(1):15. doi:10.1186/s13014-025-02589-9
2025 doi
-
[18]
MR-Guided Adaptive Radiotherapy for Head and Neck Cancer: Prospective Evaluation of Migration and Anatomical Changes of the Major Salivary Glands
van Timmeren JE, Chamberlain M, Bogowicz M, et al. MR-Guided Adaptive Radiotherapy for Head and Neck Cancer: Prospective Evaluation of Migration and Anatomical Changes of the Major Salivary Glands. Cancers (Basel). 2021;13(21):5404. doi:10.3390/cancers13215404
2021 doi
-
[19]
Sakanaka K, Ishida Y, Fujii K, et al. Radiation Dose-escalated Chemoradiotherapy Using Simultaneous Integrated Boost Intensity-Modulated Radiotherapy for Locally Advanced Unresectable Thoracic Oesophageal Squamous Cell Carcinoma: A Single- institution Phase I Study. Clin Oncol...
2021 doi
-
[20]
Interim 18F-FDG-PET based response-adaptive dose escalation of proton therapy for head and neck cancer: a treatment planning feasibility study
Garrido-Hernandez G, Henjum H, Winter RM, et al. Interim 18F-FDG-PET based response-adaptive dose escalation of proton therapy for head and neck cancer: a treatment planning feasibility study. Physica Medica. 2024;123:103404. doi:10.1016/j.ejmp.2024.103404
2024
-
[21]
Differential Response in Quantitative MRI Parameters Detected in Head and Neck Cancer Patients Treated with Concurrent Immunotherapy during Hypo-Fractionated MR-gRT
Bonate R, Paulson ES, Frei A, et al. Differential Response in Quantitative MRI Parameters Detected in Head and Neck Cancer Patients Treated with Concurrent Immunotherapy during Hypo-Fractionated MR-gRT. International Journal of Radiation Oncology*Biology*Physics. 2023;117(2, S...
2023 doi
-
[22]
Accessed June 10, 2025
Impact of circulating tumor human papillomavirus DNA kinetics on disease outcomes in HPV‐associated oropharyngeal cancer - Jhawar - 2025 - International Journal of Cancer - Wiley Online Library. Accessed June 10, 2025. https://onlinelibrary.wiley.com/doi/10.1002/ijc.35291
2025 doi
-
[23]
Cone-beam computed tomography- based online adaptive radiotherapy of esophageal cancer in the neoadjuvant setting: Dosimetric analysis, toxicity and treatment response
Bachmann N, Ahmadsei M, Hürlimann M, et al. Cone-beam computed tomography- based online adaptive radiotherapy of esophageal cancer in the neoadjuvant setting: Dosimetric analysis, toxicity and treatment response. Radiotherapy and Oncology. 2025;209:110981. doi:10.1016/j.radonc...
2025
-
[24]
A phase II study of personalized ultrafractionated stereotactic adaptive radiotherapy for palliative head and neck cancer treatment (PULS-Pal): a single-arm clinical trial protocol
Courtney PT, L Santoso M, Savjani RR, et al. A phase II study of personalized ultrafractionated stereotactic adaptive radiotherapy for palliative head and neck cancer treatment (PULS-Pal): a single-arm clinical trial protocol. BMC Cancer. 2024;24(1):1564. doi:10.1186/s12885-02...
2024 doi
-
[25]
Feasibility of Adaptive Radiation Therapy for Human-Papilloma Virus-Positive Oropharyngeal Cancer Patients Using MR- Guided RT
Jethanandani A, Freedman LM, Kubicek GJ, et al. Feasibility of Adaptive Radiation Therapy for Human-Papilloma Virus-Positive Oropharyngeal Cancer Patients Using MR- Guided RT. International Journal of Radiation Oncology, Biology, Physics. 2024;118(5):e15. doi:10.1016/j.ijrobp....
2024 doi
-
[26]
BEST (Biomarkers, EndpointS, and Other Tools) Resource
FDA-NIH Biomarker Working Group. BEST (Biomarkers, EndpointS, and Other Tools) Resource. Food and Drug Administration (US); 2016. Accessed December 29, 2024. http://www.ncbi.nlm.nih.gov/books/NBK326791/
2016
-
[27]
Imaging biomarker roadmap for cancer studies
O’Connor JPB, Aboagye EO, Adams JE, et al. Imaging biomarker roadmap for cancer studies. Nat Rev Clin Oncol. 2017;14(3):169-186. doi:10.1038/nrclinonc.2016.162
2017 doi
-
[28]
Van Houdt PJ, Saeed H, Thorwarth D, et al. Integration of quantitative imaging biomarkers in clinical trials for MR-guided radiotherapy: Conceptual guidance for multicentre studies from the MR-Linac Consortium Imaging Biomarker Working Group. European Journal of Cancer. 2021;1...
2021 doi
-
[29]
The QIBA Profile for Diffusion-Weighted MRI: Apparent Diffusion Coefficient as a Quantitative Imaging Biomarker
Boss MA, Malyarenko D, Partridge S, et al. The QIBA Profile for Diffusion-Weighted MRI: Apparent Diffusion Coefficient as a Quantitative Imaging Biomarker. Goh V, ed. Radiology. 2024;313(1):e233055. doi:10.1148/radiol.233055
2024 doi
-
[30]
Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE- AI
Vasey B, Nagendran M, Campbell B, et al. Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE- AI. BMJ. Published online May 18, 2022:e070904. doi:10.1136/bmj-2022-070904
2022 doi
-
[31]
DECIDE-AI: a new reporting guideline and its relevance to artificial intelligence studies in radiology
Vasey B, Novak A, Ather S, Ibrahim M, McCulloch P. DECIDE-AI: a new reporting guideline and its relevance to artificial intelligence studies in radiology. Clinical Radiology. 2023;78(2):130-136. doi:10.1016/j.crad.2022.09.131
2023 doi
-
[32]
R-IDEAL: A Framework for Systematic Clinical Evaluation of Technical Innovations in Radiation Oncology
Verkooijen HM, Kerkmeijer LGW, Fuller CD, et al. R-IDEAL: A Framework for Systematic Clinical Evaluation of Technical Innovations in Radiation Oncology. Front Oncol. 2017;7. doi:10.3389/fonc.2017.00059
2017
-
[33]
The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping
Zwanenburg A, Vallières M, Abdalah MA, et al. The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping. Radiology. 2020;295(2):328-338. doi:10.1148/radiol.2020191145
2020 doi
-
[34]
Bahig H, Yuan Y, Mohamed ASR, et al. Magnetic Resonance-based Response Assessment and Dose Adaptation in Human Papilloma Virus Positive Tumors of the Oropharynx treated with Radiotherapy (MR-ADAPTOR): An R-IDEAL stage 2a- 2b/Bayesian phase II trial. Clin Transl Radiat Oncol. 2...
2018 doi
-
[35]
Metrology Standards for Quantitative Imaging Biomarkers
Sullivan DC, Obuchowski NA, Kessler LG, et al. Metrology Standards for Quantitative Imaging Biomarkers. Radiology. 2015;277(3):813-825. doi:10.1148/radiol.2015142202
2015 doi
-
[36]
Image Guided Radiation Therapy (IGRT) Technologies for Radiation Therapy Localization and Delivery
De Los Santos J, Popple R, Agazaryan N, et al. Image Guided Radiation Therapy (IGRT) Technologies for Radiation Therapy Localization and Delivery. International Journal of Radiation Oncology*Biology*Physics. 2013;87(1):33-45. doi:10.1016/j.ijrobp.2013.02.021 33
2013 doi
-
[37]
Quality and Safety Considerations in Image Guided Radiation Therapy: An ASTRO Safety White Paper Update
Qi XS, Albuquerque K, Bailey S, et al. Quality and Safety Considerations in Image Guided Radiation Therapy: An ASTRO Safety White Paper Update. Practical Radiation Oncology. 2023;13(2):97-111. doi:10.1016/j.prro.2022.09.004
2023 doi
-
[38]
Image guided radiotherapy moving towards real time adaptive radiotherapy; global positioning system for radiotherapy? Technical Innovations & Patient Support in Radiation Oncology
McNair H, Buijs M. Image guided radiotherapy moving towards real time adaptive radiotherapy; global positioning system for radiotherapy? Technical Innovations & Patient Support in Radiation Oncology. 2019;12:1-2. doi:10.1016/j.tipsro.2019.10.006
2019 doi
-
[39]
Head and Neck Cancer Adaptive Radiation Therapy (ART): Conceptual Considerations for the Informed Clinician
Heukelom J, Fuller CD. Head and Neck Cancer Adaptive Radiation Therapy (ART): Conceptual Considerations for the Informed Clinician. Seminars in Radiation Oncology. 2019;29(3):258-273. doi:10.1016/j.semradonc.2019.02.008
2019 doi
-
[40]
Two novel stereotactic radiotherapy methods for locally advanced, previously irradiated head and neck cancers patients
Pokhrel D, Misa J, McCarthy S, Yang ES. Two novel stereotactic radiotherapy methods for locally advanced, previously irradiated head and neck cancers patients. Med Dosim. 2024;49(2):114-120. doi:10.1016/j.meddos.2023.09.003
2024 doi
-
[41]
Dosimetric performance evaluation of the Halcyon treatment platform for stereotactic radiotherapy: A pooled study
Huang Y, Liu Z. Dosimetric performance evaluation of the Halcyon treatment platform for stereotactic radiotherapy: A pooled study. Medicine. 2023;102(36):e34933. doi:10.1097/MD.0000000000034933
2023 doi
-
[42]
Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma
Ju SG, Ahn YC, Kim YB, et al. Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma. Radiat Oncol. 2022;17(1):155. doi:10.1186/s13014-022- 02124-0
2022 doi
-
[43]
Evaluation of auto-planning in IMRT and VMAT for head and neck cancer
Ouyang Z, Liu Shen Z, Murray E, et al. Evaluation of auto-planning in IMRT and VMAT for head and neck cancer. J Appl Clin Med Phys. 2019;20(7):39-47. doi:10.1002/acm2.12652
2019 doi
-
[44]
Characterization of the HalcyonTM multileaf collimator system
Lim TY, Dragojević I, Hoffman D, Flores-Martinez E, Kim GY. Characterization of the HalcyonTM multileaf collimator system. J Appl Clin Med Phys. 2019;20(4):106-114. doi:10.1002/acm2.12568
2019 doi
-
[45]
Benchmarking halcyon ring delivery system for hypofractionated breast radiotherapy: Validation and clinical implementation of the fast‐forward trial
Pokhrel D, Smith M, Volk A, Bernard ME. Benchmarking halcyon ring delivery system for hypofractionated breast radiotherapy: Validation and clinical implementation of the fast‐forward trial. J Applied Clin Med Phys. 2023;24(9):e14047. doi:10.1002/acm2.14047
2023 doi
-
[46]
Treatment time of image-guided radiotherapy with a Halcyon 2.0 system
Hermida-López M, García-Relancio D, Comino-Muriano M, et al. Treatment time of image-guided radiotherapy with a Halcyon 2.0 system. Journal of Medical Imaging and Radiation Sciences. 2023;54(1):117-122. doi:10.1016/j.jmir.2022.12.002
2023 doi
-
[47]
A Simulated Dosimetric Study of Contribution to Radiotherapy Accuracy by Fractional Image Guidance Protocol of Halcyon System
Wang H, Huang Y, Hu Q, et al. A Simulated Dosimetric Study of Contribution to Radiotherapy Accuracy by Fractional Image Guidance Protocol of Halcyon System. Front Oncol. 2021;10:543147. doi:10.3389/fonc.2020.543147 34
2021
-
[48]
CT-on-Rails Versus In-Room CBCT for Online Daily Adaptive Proton Therapy of Head-and-Neck Cancers
Nesteruk KP, Bobić M, Lalonde A, Winey BA, Lomax AJ, Paganetti H. CT-on-Rails Versus In-Room CBCT for Online Daily Adaptive Proton Therapy of Head-and-Neck Cancers. Cancers. 2021;13(23):5991. doi:10.3390/cancers13235991
2021 doi
-
[49]
In-room CT techniques for image-guided radiation therapy
Ma CMC, Paskalev K. In-room CT techniques for image-guided radiation therapy. Med Dosim. 2006;31(1):30-39. doi:10.1016/j.meddos.2005.12.010
2006 doi
-
[50]
Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
Barker JL, Garden AS, Ang KK, et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. International Journal of Radiation Oncology*Biology*Physics. 2004;59(4)...
2004 doi
-
[51]
Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review
Srinivasan K, Mohammadi M, Shepherd J. Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review. Pol J Radiol. 2014;79:181-193. doi:10.12659/PJR.890745
2014 doi
-
[52]
Adaptive radiotherapy for head-and-neck cancer: initial clinical outcomes from a prospective trial
Schwartz DL, Garden AS, Thomas J, et al. Adaptive radiotherapy for head-and-neck cancer: initial clinical outcomes from a prospective trial. Int J Radiat Oncol Biol Phys. 2012;83(3):986-993. doi:10.1016/j.ijrobp.2011.08.017
2012 doi
-
[53]
Personalized medicine: From diagnostic to adaptive
Braig ZV. Personalized medicine: From diagnostic to adaptive. Biomedical Journal. 2022;45(1):132-142. doi:10.1016/j.bj.2019.05.004
2022 doi
-
[54]
Review of cone beam computed tomography based online adaptive radiotherapy: current trend and future direction
Liu H, Schaal D, Curry H, et al. Review of cone beam computed tomography based online adaptive radiotherapy: current trend and future direction. Radiat Oncol. 2023;18(1):144. doi:10.1186/s13014-023-02340-2
2023 doi
-
[55]
Investigating the feasibility of using Ethos generated treatment plans for head and neck cancer patients
El-qmache A, McLellan J. Investigating the feasibility of using Ethos generated treatment plans for head and neck cancer patients. Technical Innovations & Patient Support in Radiation Oncology. 2023;27:100216. doi:10.1016/j.tipsro.2023.100216
2023
-
[56]
Evaluation of Ethos intelligent optimization engine for left locally advanced breast cancer
Prunaretty J, Lopez L, Cabaillé M, et al. Evaluation of Ethos intelligent optimization engine for left locally advanced breast cancer. Front Oncol. 2024;14:1399978. doi:10.3389/fonc.2024.1399978
2024
-
[57]
Technical feasibility of novel immunostimulatory low‐dose radiation for polymetastatic disease with CBCT‐based online adaptive and conventional approaches
Nasser N, Perez BA, Penagaricano JA, et al. Technical feasibility of novel immunostimulatory low‐dose radiation for polymetastatic disease with CBCT‐based online adaptive and conventional approaches. J Applied Clin Med Phys. 2024;25(6):e14303. doi:10.1002/acm2.14303
2024 doi
-
[58]
Varian ethos online adaptive radiotherapy for prostate cancer: Early results of contouring accuracy, treatment plan quality, and treatment time
Byrne M, Archibald‐Heeren B, Hu Y, et al. Varian ethos online adaptive radiotherapy for prostate cancer: Early results of contouring accuracy, treatment plan quality, and treatment time. J Applied Clin Med Phys. 2022;23(1):e13479. doi:10.1002/acm2.13479 35
2022 doi
-
[59]
Feasibility of Conebeam CT-based online adaptive radiotherapy for neoadjuvant treatment of rectal cancer
De Jong R, Visser J, Van Wieringen N, Wiersma J, Geijsen D, Bel A. Feasibility of Conebeam CT-based online adaptive radiotherapy for neoadjuvant treatment of rectal cancer. Radiat Oncol. 2021;16(1):136. doi:10.1186/s13014-021-01866-7
2021 doi
-
[60]
Feasibility study of adaptive radiotherapy with Ethos for breast cancer
Galand A, Prunaretty J, Mir N, et al. Feasibility study of adaptive radiotherapy with Ethos for breast cancer. Front Oncol. 2023;13:1274082. doi:10.3389/fonc.2023.1274082
2023
-
[61]
A head and neck treatment planning strategy for a CBCT‐guided ring‐gantry online adaptive radiotherapy system
Nasser N, Yang GQ, Koo J, et al. A head and neck treatment planning strategy for a CBCT‐guided ring‐gantry online adaptive radiotherapy system. J Applied Clin Med Phys. 2023;24(12):e14134. doi:10.1002/acm2.14134
2023 doi
-
[62]
Initial Evaluation of a Novel Cone-Beam CT-Based Semi-Automated Online Adaptive Radiotherapy System for Head and Neck Cancer Treatment – A Timing and Automation Quality Study
Yoon SW, Lin H, Alonso-Basanta M, et al. Initial Evaluation of a Novel Cone-Beam CT-Based Semi-Automated Online Adaptive Radiotherapy System for Head and Neck Cancer Treatment – A Timing and Automation Quality Study. Cureus. Published online August 11, 2020. doi:10.7759/cureus.9660
2020 doi
-
[63]
Early Experience of Online Adaptive Radiation Therapy for Definitive Radiation of Patients With Head and Neck Cancer
Avkshtol V, Meng B, Shen C, et al. Early Experience of Online Adaptive Radiation Therapy for Definitive Radiation of Patients With Head and Neck Cancer. Advances in Radiation Oncology. 2023;8(5):101256. doi:10.1016/j.adro.2023.101256
2023
-
[64]
Prospects for online adaptive radiation therapy (ART) for head and neck cancer
Guberina M, Guberina N, Hoffmann C, et al. Prospects for online adaptive radiation therapy (ART) for head and neck cancer. Radiat Oncol. 2024;19(1):4. doi:10.1186/s13014-023-02390-6
2024 doi
-
[65]
MRI-LINAC: A transformative technology in radiation oncology
Ng J, Gregucci F, Pennell RT, et al. MRI-LINAC: A transformative technology in radiation oncology. Front Oncol. 2023;13:1117874. doi:10.3389/fonc.2023.1117874
2023
-
[66]
Clinical application of MR-Linac in tumor radiotherapy: a systematic review
Liu X, Li Z, Yin Y. Clinical application of MR-Linac in tumor radiotherapy: a systematic review. Radiat Oncol. 2023;18(1):52. doi:10.1186/s13014-023-02221-8
2023 doi
-
[67]
Adaptive radiotherapy: The Elekta Unity MR-linac concept
Winkel D, Bol GH, Kroon PS, et al. Adaptive radiotherapy: The Elekta Unity MR-linac concept. Clinical and Translational Radiation Oncology. 2019;18:54-59. doi:10.1016/j.ctro.2019.04.001
2019 doi
-
[68]
Evaluation of Unity 1.5 T MR‐linac plan quality in patients with prostate cancer
Tanaka S, Kadoya N, Ishizawa M, et al. Evaluation of Unity 1.5 T MR‐linac plan quality in patients with prostate cancer. J Applied Clin Med Phys. 2023;24(12):e14122. doi:10.1002/acm2.14122
2023 doi
-
[69]
Evaluation of MRI‐only based online adaptive radiotherapy of abdominal region on MR‐ linac
Nousiainen K, Santurio GV, Lundahl N, Cronholm R, Siversson C, Edmund JM. Evaluation of MRI‐only based online adaptive radiotherapy of abdominal region on MR‐ linac. J Applied Clin Med Phys. 2023;24(3):e13838. doi:10.1002/acm2.13838
2023 doi
-
[70]
MR‐linac is the best modality for lung SBRT
Godley A, Zheng D, Rong Y. MR‐linac is the best modality for lung SBRT. J Applied Clin Med Phys. 2019;20(6):7-11. doi:10.1002/acm2.12615 36
2019 doi
-
[71]
The Use of MR-Guided Radiation Therapy for Head and Neck Cancer and Recommended Reporting Guidance
McDonald BA, Dal Bello R, Fuller CD, Balermpas P. The Use of MR-Guided Radiation Therapy for Head and Neck Cancer and Recommended Reporting Guidance. Seminars in Radiation Oncology. 2024;34(1):69-83. doi:10.1016/j.semradonc.2023.10.003
2024 doi
-
[72]
Magnetic resonance linear accelerator technology and adaptive radiation therapy: An overview for clinicians
Hall WA, Paulson E, Li XA, et al. Magnetic resonance linear accelerator technology and adaptive radiation therapy: An overview for clinicians. CA A Cancer J Clinicians. 2022;72(1):34-56. doi:10.3322/caac.21707
2022 doi
-
[73]
Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation
McDonald BA, Zachiu C, Christodouleas J, et al. Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation. Front Oncol. 2023;12:1086258. doi:10.3389/fonc.2022.1086258
2023
-
[74]
A survey on deep learning in medical image analysis
Litjens G, Kooi T, Bejnordi BE, et al. A survey on deep learning in medical image analysis. Medical Image Analysis. 2017;42:60-88. doi:10.1016/j.media.2017.07.005
2017 doi
-
[75]
Deep Learning in Medical Image Analysis
Shen D, Wu G, Suk HI. Deep Learning in Medical Image Analysis. Annu Rev Biomed Eng. 2017;19:221-248. doi:10.1146/annurev-bioeng-071516-044442
2017 doi
-
[76]
UNet++: A Nested U-Net Architecture for Medical Image Segmentation
Zhou Z, Siddiquee MMR, Tajbakhsh N, Liang J. UNet++: A Nested U-Net Architecture for Medical Image Segmentation. Deep Learn Med Image Anal Multimodal Learn Clin Decis Support (2018). 2018;11045:3-11. doi:10.1007/978-3-030-00889-5_1
2018 doi
-
[77]
Dermatologist-level classification of skin cancer with deep neural networks
Esteva A, Kuprel B, Novoa RA, et al. Dermatologist-level classification of skin cancer with deep neural networks. Nature. 2017;542(7639):115-118. doi:10.1038/nature21056
2017 doi
-
[78]
The role of artificial intelligence in radiotherapy clinical practice
Landry G, Kurz C, Traverso A. The role of artificial intelligence in radiotherapy clinical practice. BJR|Open. 2023;5(1):20230030. doi:10.1259/bjro.20230030
2023 doi
-
[79]
Automated Contouring and Planning in Radiation Therapy: What Is ‘Clinically Acceptable’? Diagnostics
Baroudi H, Brock KK, Cao W, et al. Automated Contouring and Planning in Radiation Therapy: What Is ‘Clinically Acceptable’? Diagnostics. 2023;13(4):667. doi:10.3390/diagnostics13040667
2023 doi
-
[80]
Artificial Intelligence Uncertainty Quantification in Radiotherapy Applications - A Scoping Review
Wahid KA, Kaffey ZY, Farris DP, et al. Artificial Intelligence Uncertainty Quantification in Radiotherapy Applications - A Scoping Review. Published online May 13, 2024. doi:10.1101/2024.05.13.24307226
2024 doi
-
[81]
Embracing imperfect datasets: A review of deep learning solutions for medical image segmentation
Tajbakhsh N, Jeyaseelan L, Li Q, Chiang JN, Wu Z, Ding X. Embracing imperfect datasets: A review of deep learning solutions for medical image segmentation. Medical Image Analysis. 2020;63:101693. doi:10.1016/j.media.2020.101693
2020
-
[82]
The technical design and concept of a PET/CT linac for biology-guided radiotherapy
Oderinde OM, Shirvani SM, Olcott PD, Kuduvalli G, Mazin S, Larkin D. The technical design and concept of a PET/CT linac for biology-guided radiotherapy. Clinical and Translational Radiation Oncology. 2021;29:106-112. doi:10.1016/j.ctro.2021.04.003 37
2021 doi
-
[83]
Treatment planning system commissioning of the first clinical biology‐guided radiotherapy machine
Simiele E, Capaldi D, Breitkreutz D, et al. Treatment planning system commissioning of the first clinical biology‐guided radiotherapy machine. J Applied Clin Med Phys. 2022;23(8):e13638. doi:10.1002/acm2.13638
2022 doi
-
[84]
Commissioning of a novel PET‐Linac for biology‐guided radiotherapy (BgRT)
Surucu M, Ashraf MR, Romero IO, et al. Commissioning of a novel PET‐Linac for biology‐guided radiotherapy (BgRT). Medical Physics. 2024;51(6):4389-4401. doi:10.1002/mp.17114
2024 doi
-
[85]
Demonstration of real‐time positron emission tomography biology‐guided radiotherapy delivery to targets
Oderinde OM, Narayanan M, Olcott P, et al. Demonstration of real‐time positron emission tomography biology‐guided radiotherapy delivery to targets. Medical Physics. 2024;51(8):5672-5681. doi:10.1002/mp.16999
2024 doi
-
[86]
Image-mode performance characterisation of a positron emission tomography subsystem designed for Biology-guided radiotherapy (BgRT)
Hu Z, Bieniosek M, Ferri V, et al. Image-mode performance characterisation of a positron emission tomography subsystem designed for Biology-guided radiotherapy (BgRT). The British Journal of Radiology. 2023;96(1141):20220387. doi:10.1259/bjr.20220387
2023 doi
-
[87]
Beam commissioning of the first clinical biology‐guided radiotherapy system
Han B, Capaldi D, Kovalchuk N, et al. Beam commissioning of the first clinical biology‐guided radiotherapy system. J Applied Clin Med Phys. 2022;23(6):e13607. doi:10.1002/acm2.13607
2022 doi
-
[88]
Comparative evaluation of treatment plan quality for a prototype biology-guided radiotherapy system in the treatment of nasopharyngeal carcinoma
Han C, Da Silva AJ, Liang J, et al. Comparative evaluation of treatment plan quality for a prototype biology-guided radiotherapy system in the treatment of nasopharyngeal carcinoma. Medical Dosimetry. 2021;46(2):171-178. doi:10.1016/j.meddos.2020.11.002
2021 doi
-
[89]
A detailed process map for clinical workflow of a new biology‐guided radiotherapy (BgRT) machine
Hwang M, Lalonde R, Huq MS. A detailed process map for clinical workflow of a new biology‐guided radiotherapy (BgRT) machine. J Applied Clin Med Phys. 2022;23(6):e13606. doi:10.1002/acm2.13606
2022 doi
-
[90]
IMRT and SBRT Treatment Planning Study for the First Clinical Biology-Guided Radiotherapy System
Pham D, Simiele E, Breitkreutz D, et al. IMRT and SBRT Treatment Planning Study for the First Clinical Biology-Guided Radiotherapy System. Technol Cancer Res Treat. 2022;21:153303382211002. doi:10.1177/15330338221100231
2022 doi
-
[91]
First-Year Experience of Stereotactic Body Radiation Therapy/Intensity Modulated Radiation Therapy Treatment Using a Novel Biology-Guided Radiation Therapy Machine
Shi M, Simiele E, Han B, et al. First-Year Experience of Stereotactic Body Radiation Therapy/Intensity Modulated Radiation Therapy Treatment Using a Novel Biology-Guided Radiation Therapy Machine. Advances in Radiation Oncology. 2024;9(1):101300. doi:10.1016/j.adro.2023.101300
2024
-
[92]
89Zr-panitumumab Combined With 18F- FDG PET Improves Detection and Staging of Head and Neck Squamous Cell Carcinoma
Lee YJ, Van Den Berg NS, Duan H, et al. 89Zr-panitumumab Combined With 18F- FDG PET Improves Detection and Staging of Head and Neck Squamous Cell Carcinoma. Clinical Cancer Research. 2022;28(20):4425-4434. doi:10.1158/1078-0432.CCR-22- 0094 38
2022 doi
-
[93]
[68Ga]-DOTATATE PET/MRI in the diagnosis and management of recurrent head and neck paraganglioma with spinal metastasis
Kim SH, Roytman M, Kamen E, et al. [68Ga]-DOTATATE PET/MRI in the diagnosis and management of recurrent head and neck paraganglioma with spinal metastasis. Clinical Imaging. 2021;79:314-318. doi:10.1016/j.clinimag.2021.07.028
2021 doi
-
[94]
Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR- Linac
Jassar H, Tai A, Chen X, et al. Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR- Linac. Med Phys. 2023;50(5):3103-3116. doi:10.1002/mp.16342
2023 doi
-
[95]
Gating and intrafraction drift correction on a 1.5 T MR-Linac: Clinical dosimetric benefits for upper abdominal tumors
Grimbergen G, Hackett SL, Van Ommen F, et al. Gating and intrafraction drift correction on a 1.5 T MR-Linac: Clinical dosimetric benefits for upper abdominal tumors. Radiotherapy and Oncology. 2023;189:109932. doi:10.1016/j.radonc.2023.109932
2023
-
[96]
RA, Feigenberg SJ, Konski AA
Cohen RJ, Paskalev K, Litwin S, Price Jr. RA, Feigenberg SJ, Konski AA. Original article: Esophageal motion during radiotherapy: quantification and margin implications: Esophageal motion during radiotherapy. Diseases of the Esophagus. 2010;23(6):473-
2010
-
[97]
Internal margin assessment using cine MRI analysis of deglutition in head and neck cancer radiotherapy
Paulson ES, Bradley JA, Wang D, Ahunbay EE, Schultz C, Li XA. Internal margin assessment using cine MRI analysis of deglutition in head and neck cancer radiotherapy. Medical Physics. 2011;38(4):1740-1747. doi:10.1118/1.3560418
2011 doi
-
[98]
Dynamic MRI Analysis of Tumor and Organ Motion During Rest and Deglutition and Margin Assessment for Radiotherapy of Head-and-Neck Cancer
Bradley JA, Paulson ES, Ahunbay E, Schultz C, Li XA, Wang D. Dynamic MRI Analysis of Tumor and Organ Motion During Rest and Deglutition and Margin Assessment for Radiotherapy of Head-and-Neck Cancer. International Journal of Radiation Oncology*Biology*Physics. 2011;81(5):e803-...
2011 doi
-
[99]
Li H, Chen HC, Dolly S, et al. An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy: In- treatment upper airway motion tracking using cine MRI. Med Phys. 2016;43(8Part1):4700-4710. doi:10.1118/1.4955118
2016 doi
-
[100]
Diffusion weighted imaging: Technique and applications
Baliyan V, Das CJ, Sharma R, Gupta AK. Diffusion weighted imaging: Technique and applications. WJR. 2016;8(9):785. doi:10.4329/wjr.v8.i9.785
2016 doi
-
[101]
Diffusion-weighted imaging and apparent diffusion coefficient mapping of head and neck lymph node metastasis: a systematic review
Belfiore MP, Nardone V, D’Onofrio I, et al. Diffusion-weighted imaging and apparent diffusion coefficient mapping of head and neck lymph node metastasis: a systematic review. Exploration of Targeted Anti-tumor Therapy. Published online December 13, 2022:734-745. doi:10.37349/e...
2022
-
[102]
Joint Head and Neck Radiotherapy-MRI Development Cooperative, Mohamed ASR, Abusaif A, et al. Prospective validation of diffusion-weighted MRI as a biomarker of tumor response and oncologic outcomes in head and neck cancer: Results from an observational biomarker pre-qualificat...
2022 doi
-
[103]
McDonald BA, Salzillo T, Mulder S, et al. In Vivo and Phantom Repeatability of Diffusion-Weighted MRI Sequences on 1.5T MRI-Linear Accelerator (MR-Linac) and MR Simulator Devices for Head and Neck Cancers: Results from a Prospective R-IDEAL Stage 2a Evaluation of Tumor and Nor...
2022 doi
-
[104]
McDonald BA, Salzillo T, Mulder S, et al. Prospective evaluation of in vivo and phantom repeatability and reproducibility of diffusion-weighted MRI sequences on 1.5 T MRI-linear accelerator (MR-Linac) and MR simulator devices for head and neck cancers. Radiotherapy and Oncolog...
2023
-
[105]
El-Habashy DM, Wahid KA, He R, et al. Longitudinal diffusion and volumetric kinetics of head and neck cancer magnetic resonance on a 1.5 T MR-linear accelerator hybrid system: A prospective R-IDEAL stage 2a imaging biomarker characterization/pre- qualification study. Clinical ...
2023
-
[106]
Joint Head and Neck Radiation Therapy-MRI Development Cooperative, MR-Linac Consortium Head and Neck Tumor Site Group, El-Habashy DM, et al. Longitudinal diffusion and volumetric kinetics of head and neck cancer magnetic resonance on a 1.5T MR-Linear accelerator hybrid system:...
2023 doi
-
[107]
Weekly Intra-Treatment Diffusion Weighted Imaging Dataset for Head and Neck Cancer Patients Undergoing MR-linac Treatment
El-Habashy DM, Wahid KA, He R, et al. Weekly Intra-Treatment Diffusion Weighted Imaging Dataset for Head and Neck Cancer Patients Undergoing MR-linac Treatment. Published online August 20, 2023. doi:10.1101/2023.08.18.23294280
2023 doi
-
[108]
Dataset of weekly intra-treatment diffusion weighted imaging in head and neck cancer patients treated with MR-Linac
El-Habashy DM, Wahid KA, He R, et al. Dataset of weekly intra-treatment diffusion weighted imaging in head and neck cancer patients treated with MR-Linac. Sci Data. 2024;11(1):487. doi:10.1038/s41597-024-03217-z
2024 doi
-
[109]
ADC measurements on the Unity MR-linac – A recommendation on behalf of the Elekta Unity MR-linac consortium
Kooreman ES, Van Houdt PJ, Keesman R, et al. ADC measurements on the Unity MR-linac – A recommendation on behalf of the Elekta Unity MR-linac consortium. Radiotherapy and Oncology. 2020;153:106-113. doi:10.1016/j.radonc.2020.09.046
2020 doi
-
[110]
Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system
Nakao M, Ozawa S, Yamada K, et al. Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system. J Applied Clin Med Phys. 2018;19(1):271-275. doi:10.1002/acm2.12226
2018 doi
-
[111]
Influence of different factors on registration error in a 1.5 T MR-guided linac
Yin P, Yu G, Hou C, et al. Influence of different factors on registration error in a 1.5 T MR-guided linac. Phys Med Biol. 2023;68(10):10NT02. doi:10.1088/1361-6560/accef9 40
2023 doi
-
[112]
Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head
Yu H, Caldwell C, Balogh J, Mah K. Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head. International Journal of Radiation Oncology*Biology*Physics. 2014;89(3):649-657. doi:10.1016/j.ijrobp.2014.03.028
2014 doi
-
[113]
Multiatlas approach with local registration goodness weighting for MRI-based electron density mapping of head and neck anatomy
Farjam R, Tyagi N, Veeraraghavan H, et al. Multiatlas approach with local registration goodness weighting for MRI-based electron density mapping of head and neck anatomy. Med Phys. 2017;44(7):3706-3717. doi:10.1002/mp.12303
2017 doi
-
[114]
Shape constrained fully convolutional DenseNet with adversarial training for multiorgan segmentation on head and neck CT and low‐field MR images
Tong N, Gou S, Yang S, Cao M, Sheng K. Shape constrained fully convolutional DenseNet with adversarial training for multiorgan segmentation on head and neck CT and low‐field MR images. Medical Physics. 2019;46(6):2669-2682. doi:10.1002/mp.13553
2019 doi
-
[115]
Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch‐based three‐dimensional convolutional neural network
Dinkla AM, Florkow MC, Maspero M, et al. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch‐based three‐dimensional convolutional neural network. Medical Physics. 2019;46(9):4095-4104. doi:10.1002/mp.13663
2019 doi
-
[116]
Patch‐based generative adversarial neural network models for head and neck MR‐only planning
Klages P, Benslimane I, Riyahi S, et al. Patch‐based generative adversarial neural network models for head and neck MR‐only planning. Medical Physics. 2020;47(2):626-
2020
-
[117]
Generation of synthetic megavoltage CT for MRI‐only radiotherapy treatment planning using a 3D deep convolutional neural network
Scholey JE, Rajagopal A, Vasquez EG, Sudhyadhom A, Larson PEZ. Generation of synthetic megavoltage CT for MRI‐only radiotherapy treatment planning using a 3D deep convolutional neural network. Medical Physics. 2022;49(10):6622-6634. doi:10.1002/mp.15876
2022 doi
-
[118]
Compensation cycle consistent generative adversarial networks (Comp‐GAN) for synthetic CT generation from MR scans with truncated anatomy
Zhao Y, Wang H, Yu C, et al. Compensation cycle consistent generative adversarial networks (Comp‐GAN) for synthetic CT generation from MR scans with truncated anatomy. Medical Physics. 2023;50(7):4399-4414. doi:10.1002/mp.16246
2023 doi
-
[119]
SC-GAN: Structure-completion generative adversarial network for synthetic CT generation from MR images with truncated anatomy
Chen X, Zhao Y, Court LE, et al. SC-GAN: Structure-completion generative adversarial network for synthetic CT generation from MR images with truncated anatomy. Computerized Medical Imaging and Graphics. 2024;113:102353. doi:10.1016/j.compmedimag.2024.102353
2024
-
[120]
Multisequence MR‐generated sCT is promising for HNC MR‐only RT: A comprehensive evaluation of previously developed sCT generation networks
Qi M, Li Y, Wu A, Lu X, Zhou L, Song T. Multisequence MR‐generated sCT is promising for HNC MR‐only RT: A comprehensive evaluation of previously developed sCT generation networks. Medical Physics. 2022;49(4):2150-2158. doi:10.1002/mp.15572
2022 doi
-
[121]
Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy
Mandija S, D’Agata F, Navest RJM, et al. Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy. Front Oncol. 2019;9:647. doi:10.3389/fonc.2019.00647 41
2019
-
[122]
A pilot study of same-day MRI-only simulation and treatment with MR-guided adaptive palliative radiotherapy (MAP-RT)
Schiff JP, Maraghechi B, Chin RI, et al. A pilot study of same-day MRI-only simulation and treatment with MR-guided adaptive palliative radiotherapy (MAP-RT). Clinical and Translational Radiation Oncology. 2023;39:100561. doi:10.1016/j.ctro.2022.100561
2023
-
[123]
A Systematic Review of the Clinical Implementation of Pelvic Magnetic Resonance Imaging–Only Planning for External Beam Radiation Therapy
Bird D, Henry AM, Sebag-Montefiore D, Buckley DL, Al-Qaisieh B, Speight R. A Systematic Review of the Clinical Implementation of Pelvic Magnetic Resonance Imaging–Only Planning for External Beam Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics. 20...
2019 doi
-
[124]
Dynamic contrast-enhanced magnetic resonance imaging: fundamentals and application to the evaluation of the peripheral perfusion
Gordon Y, Partovi S, Müller-Eschner M, et al. Dynamic contrast-enhanced magnetic resonance imaging: fundamentals and application to the evaluation of the peripheral perfusion. Cardiovasc Diagn Ther. 2014;4(2):147-164. doi:10.3978/j.issn.2223- 3652.2014.03.01
2014
-
[125]
Models and methods for analyzing DCE‐MRI: A review
Khalifa F, Soliman A, El‐Baz A, et al. Models and methods for analyzing DCE‐MRI: A review. Medical Physics. 2014;41(12):124301. doi:10.1118/1.4898202
2014 doi
-
[126]
Review of dynamic contrast‐enhanced MRI: Technical aspects and applications in the musculoskeletal system
Sujlana P, Skrok J, Fayad LM. Review of dynamic contrast‐enhanced MRI: Technical aspects and applications in the musculoskeletal system. Magnetic Resonance Imaging. 2018;47(4):875-890. doi:10.1002/jmri.25810
2018 doi
-
[127]
Value of Dynamic Contrast-Enhanced MR Imaging in Diagnosing and Classifying Peripheral Vascular Malformations
Van Rijswijk CSP, Van Der Linden E, Van Der Woude HJ, Van Baalen JM, Bloem JL. Value of Dynamic Contrast-Enhanced MR Imaging in Diagnosing and Classifying Peripheral Vascular Malformations. American Journal of Roentgenology. 2002;178(5):1181-1187. doi:10.2214/ajr.178.5.1781181
2002 doi
-
[128]
Quantitative Dynamic Contrast-Enhanced MRI Identifies Radiation-Induced Vascular Damage in Patients With Advanced Osteoradionecrosis: Results of a Prospective Study
Mohamed ASR, He R, Ding Y, et al. Quantitative Dynamic Contrast-Enhanced MRI Identifies Radiation-Induced Vascular Damage in Patients With Advanced Osteoradionecrosis: Results of a Prospective Study. International Journal of Radiation Oncology*Biology*Physics. 2020;108(5):1319...
2020 doi
-
[129]
Glycerol-weighted chemical exchange saturation transfer nanoprobes allow 19F/1H dual-modality magnetic resonance imaging-guided cancer radiotherapy
A R, Wang H, Nie C, et al. Glycerol-weighted chemical exchange saturation transfer nanoprobes allow 19F/1H dual-modality magnetic resonance imaging-guided cancer radiotherapy. Nat Commun. 2023;14(1):6644. doi:10.1038/s41467-023-42286-3
2023 doi
-
[130]
Magnetic Resonance Imaging of Glucose Uptake and Metabolism in Patients with Head and Neck Cancer
Wang J, Weygand J, Hwang KP, et al. Magnetic Resonance Imaging of Glucose Uptake and Metabolism in Patients with Head and Neck Cancer. Sci Rep. 2016;6(1):30618. doi:10.1038/srep30618
2016 doi
-
[131]
Liu W, Wang X, Xie S, et al. Amide proton transfer (APT) and magnetization transfer (MT) in predicting short-term therapeutic outcome in nasopharyngeal carcinoma after chemoradiotherapy: a feasibility study of three-dimensional chemical exchange 42 saturation transfer (CEST) M...
2023 doi
-
[132]
Chemical exchange saturation transfer MRI in central nervous system tumours on a 1.5 T MR-Linac
Chan RW, Lawrence LSP, Oglesby RT, et al. Chemical exchange saturation transfer MRI in central nervous system tumours on a 1.5 T MR-Linac. Radiotherapy and Oncology. 2021;162:140-149. doi:10.1016/j.radonc.2021.07.010
2021 doi
-
[133]
Semi‐solid MT and APTW CEST‐MRI predict clinical outcome of patients with glioma early after radiotherapy
Kroh F, Von Knebel Doeberitz N, Breitling J, et al. Semi‐solid MT and APTW CEST‐MRI predict clinical outcome of patients with glioma early after radiotherapy. Magnetic Resonance in Med. 2023;90(4):1569-1581. doi:10.1002/mrm.29746
2023 doi
-
[134]
Evaluation of Glioblastoma Response to Therapy With Chemical Exchange Saturation Transfer
Mehrabian H, Myrehaug S, Soliman H, Sahgal A, Stanisz GJ. Evaluation of Glioblastoma Response to Therapy With Chemical Exchange Saturation Transfer. International Journal of Radiation Oncology*Biology*Physics. 2018;101(3):713-723. doi:10.1016/j.ijrobp.2018.03.057
2018 doi
-
[135]
Differentiation between Radiation Necrosis and Tumor Progression Using Chemical Exchange Saturation Transfer
Mehrabian H, Desmond KL, Soliman H, Sahgal A, Stanisz GJ. Differentiation between Radiation Necrosis and Tumor Progression Using Chemical Exchange Saturation Transfer. Clinical Cancer Research. 2017;23(14):3667-3675. doi:10.1158/1078-0432.CCR-16-2265
2017 doi
-
[136]
Chemical Exchange Saturation Transfer MRI for Differentiating Radiation Necrosis From Tumor Progression in Brain Metastasis— Application in a Clinical Setting
Mehrabian H, Chan RW, Sahgal A, et al. Chemical Exchange Saturation Transfer MRI for Differentiating Radiation Necrosis From Tumor Progression in Brain Metastasis— Application in a Clinical Setting. Magnetic Resonance Imaging. 2023;57(6):1713-1725. doi:10.1002/jmri.28440
2023 doi
-
[137]
CEST imaging of the APT and ssMT predict the overall survival of patients with glioma at the first follow-up after completion of radiotherapy at 3T
Von Knebel Doeberitz N, Kroh F, Breitling J, et al. CEST imaging of the APT and ssMT predict the overall survival of patients with glioma at the first follow-up after completion of radiotherapy at 3T. Radiotherapy and Oncology. 2023;184:109694. doi:10.1016/j.radonc.2023.109694
2023
-
[138]
Relaxation-compensated amide proton transfer (APT) MRI signal intensity is associated with survival and progression in high-grade glioma patients
Paech D, Dreher C, Regnery S, et al. Relaxation-compensated amide proton transfer (APT) MRI signal intensity is associated with survival and progression in high-grade glioma patients. Eur Radiol. 2019;29(9):4957-4967. doi:10.1007/s00330-019-06066-2
2019 doi
-
[139]
Post-Surgical Depositions of Blood Products Are No Major Confounder for the Diagnostic and Prognostic Performance of CEST MRI in Patients with Glioma
Von Knebel Doeberitz N, Kroh F, König L, et al. Post-Surgical Depositions of Blood Products Are No Major Confounder for the Diagnostic and Prognostic Performance of CEST MRI in Patients with Glioma. Biomedicines. 2023;11(9):2348. doi:10.3390/biomedicines11092348
2023 doi
-
[140]
Performance of amide proton transfer imaging to differentiate true progression from therapy-related changes in gliomas and metastases
Essed RA, Prysiazhniuk Y, Wamelink IJ, Azizova A, Keil VC. Performance of amide proton transfer imaging to differentiate true progression from therapy-related changes in gliomas and metastases. Eur Radiol. Published online August 12, 2024. doi:10.1007/s00330-024-11004-y 43
2024 doi
-
[141]
Chemical Exchange Saturation Transfer MRI : Capability for Predicting Therapeutic Effect of Chemoradiotherapy on Non‐Small Cell Lung Cancer Patients
Ohno Y, Yui M, Yamamoto K, et al. Chemical Exchange Saturation Transfer MRI : Capability for Predicting Therapeutic Effect of Chemoradiotherapy on Non‐Small Cell Lung Cancer Patients. Magnetic Resonance Imaging. 2023;58(1):174-186. doi:10.1002/jmri.28691
2023 doi
-
[142]
Towards differentiation of brain tumor from radiation necrosis using multi-parametric MRI: Preliminary results at 4.7 T using rodent models
Devan SP, Jiang X, Kang H, et al. Towards differentiation of brain tumor from radiation necrosis using multi-parametric MRI: Preliminary results at 4.7 T using rodent models. Magnetic Resonance Imaging. 2022;94:144-150. doi:10.1016/j.mri.2022.10.002
2022 doi
-
[143]
Glioblastoma (GBM) effects on quantitative MRI of contralateral normal appearing white matter
Mehrabian H, Lam WW, Myrehaug S, Sahgal A, Stanisz GJ. Glioblastoma (GBM) effects on quantitative MRI of contralateral normal appearing white matter. J Neurooncol. 2018;139(1):97-106. doi:10.1007/s11060-018-2846-0
2018 doi
-
[144]
Quantitative CEST and MT at 1.5T for monitoring treatment response in glioblastoma: early and late tumor progression during chemoradiation
Chan RW, Chen H, Myrehaug S, et al. Quantitative CEST and MT at 1.5T for monitoring treatment response in glioblastoma: early and late tumor progression during chemoradiation. J Neurooncol. 2021;151(2):267-278. doi:10.1007/s11060-020-03661-y
2021 doi
-
[145]
Chemical exchange saturation transfer MRI serves as predictor of early progression in glioblastoma patients
Regnery S, Adeberg S, Dreher C, et al. Chemical exchange saturation transfer MRI serves as predictor of early progression in glioblastoma patients. Oncotarget. 2018;9(47):28772-28783. doi:10.18632/oncotarget.25594
2018 doi
-
[146]
Chemical exchange saturation transfer for predicting response to stereotactic radiosurgery in human brain metastasis
Desmond KL, Mehrabian H, Chavez S, et al. Chemical exchange saturation transfer for predicting response to stereotactic radiosurgery in human brain metastasis. Magnetic Resonance in Med. 2017;78(3):1110-1120. doi:10.1002/mrm.26470
2017 doi
-
[147]
Early response assessment of glioma patients to definitive chemoradiotherapy using chemical exchange saturation transfer imaging at 7 T
Meissner J, Korzowski A, Regnery S, et al. Early response assessment of glioma patients to definitive chemoradiotherapy using chemical exchange saturation transfer imaging at 7 T. Magnetic Resonance Imaging. 2019;50(4):1268-1277. doi:10.1002/jmri.26702
2019 doi
-
[148]
Artifacts in T1ρ-weighted imaging: Compensation for B1 and B0 field imperfections
Witschey WRT, Borthakur A, Elliott MA, et al. Artifacts in T1ρ-weighted imaging: Compensation for B1 and B0 field imperfections. Journal of Magnetic Resonance. 2007;186(1):75-85. doi:10.1016/j.jmr.2007.01.015
2007 doi
-
[149]
Differentiation of brain tumor- related edema based on 3D T1rho imaging
Villanueva-Meyer JE, Barajas RF, Mabray MC, et al. Differentiation of brain tumor- related edema based on 3D T1rho imaging. European Journal of Radiology. 2017;91:88-
2017
-
[150]
Impact of Liver Fibrosis and Fatty Liver on T1rho Measurements: A Prospective Study
Xie S, Li Q, Cheng Y, et al. Impact of Liver Fibrosis and Fatty Liver on T1rho Measurements: A Prospective Study. Korean J Radiol. 2017;18(6):898. doi:10.3348/kjr.2017.18.6.898
2017 doi
-
[151]
T1ρ for Radiotherapy Treatment Response Monitoring in Rectal Cancer Patients: A Pilot Study
Kooreman ES, Tanaka M, Ter Beek LC, et al. T1ρ for Radiotherapy Treatment Response Monitoring in Rectal Cancer Patients: A Pilot Study. JCM. 2022;11(7):1998. doi:10.3390/jcm11071998 44
2022 doi
-
[152]
doi:10.1016/j.ejrad.2017.03.022
2017 doi
-
[153]
The Quality Assurance of a 1.5 T MR-Linac
Riis HL, Chick J, Dunlop A, Tilly D. The Quality Assurance of a 1.5 T MR-Linac. Seminars in Radiation Oncology. 2024;34(1):120-128. doi:10.1016/j.semradonc.2023.10.011
2024 doi
-
[154]
Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs
Keenan KE, Biller JR, Delfino JG, et al. Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs. Magnetic Resonance Imaging. 2019;49(7). doi:10.1002/jmri.26598
2019 doi
-
[155]
The QIBA Profile for MRI-based Compositional Imaging of Knee Cartilage
Chalian M, Li X, Guermazi A, et al. The QIBA Profile for MRI-based Compositional Imaging of Knee Cartilage. Radiology. 2021;301(2):423-432. doi:10.1148/radiol.2021204587
2021 doi
-
[156]
BOLD MRI of human tumor oxygenation during carbogen breathing
Taylor NJ, Baddeley H, Goodchild KA, et al. BOLD MRI of human tumor oxygenation during carbogen breathing. Magnetic Resonance Imaging. 2001;14(2):156-163. doi:10.1002/jmri.1166
2001 doi
-
[157]
Correlations of noninvasive BOLD and TOLD MRI with pO 2 and relevance to tumor radiation response: Noninvasive BOLD and TOLD MRI of Tumors
Hallac RR, Zhou H, Pidikiti R, et al. Correlations of noninvasive BOLD and TOLD MRI with pO 2 and relevance to tumor radiation response: Noninvasive BOLD and TOLD MRI of Tumors. Magn Reson Med. 2014;71(5):1863-1873. doi:10.1002/mrm.24846
2014 doi
-
[158]
The Hallmarks of Cancer
Hanahan D, Weinberg RA. The Hallmarks of Cancer. Cell. 2000;100(1):57-70. doi:10.1016/S0092-8674(00)81683-9
2000 doi
-
[159]
Repeatability and sensitivity of measurements in patients with head and neck squamous cell carcinoma at 3T
Panek R, Welsh L, Dunlop A, et al. Repeatability and sensitivity of measurements in patients with head and neck squamous cell carcinoma at 3T. Magnetic Resonance Imaging. 2016;44(1):72-80. doi:10.1002/jmri.25134
2016 doi
-
[160]
First-in-human technique translation of oxygen-enhanced MRI to an MR Linac system in patients with head and neck cancer
Dubec MJ, Buckley DL, Berks M, et al. First-in-human technique translation of oxygen-enhanced MRI to an MR Linac system in patients with head and neck cancer. Radiotherapy and Oncology. 2023;183:109592. doi:10.1016/j.radonc.2023.109592
2023
-
[161]
Monitoring of Tumor Oxygenation Changes in Head-and-Neck Carcinoma Patients Breathing a Hyperoxic Hypercapnic Gas Mixture with a Noninvasive MRI Technique
Kotas M, Schmitt P, Jakob PM, Flentje M. Monitoring of Tumor Oxygenation Changes in Head-and-Neck Carcinoma Patients Breathing a Hyperoxic Hypercapnic Gas Mixture with a Noninvasive MRI Technique. Strahlenther Onkol. 2009;185(1):19-26. doi:10.1007/s00066-009-1870-6
2009 doi
-
[162]
Nephrogenic systemic fibrosis and gadolinium-based contrast agents
High WA. Nephrogenic systemic fibrosis and gadolinium-based contrast agents. Expert Review of Dermatology. 2007;2(5):593-605. doi:10.1586/17469872.2.5.593 45
2007 doi
-
[163]
Tissue specific perfusion imaging using arterial spin labeling
Detre JA, Zhang W, Roberts DA, et al. Tissue specific perfusion imaging using arterial spin labeling. NMR in Biomedicine. 1994;7(1-2):75-82. doi:10.1002/nbm.1940070112
1994 doi
-
[164]
Towards tumour hypoxia imaging: Incorporating relative oxygen extraction fraction mapping of prostate with multi‐ parametric quantitative MRI on a 1
Mesny E, Leporq B, Chapet O, Beuf O. Towards tumour hypoxia imaging: Incorporating relative oxygen extraction fraction mapping of prostate with multi‐ parametric quantitative MRI on a 1. 5T MR ‐linac. J Med Imag Rad Onc. 2024;68(2):171-
2024
-
[165]
Multidelay pseudocontinuous arterial spin labeling to measure blood flow in the head and neck
Sijtsema ND, Petit SF, Verduijn GM, et al. Multidelay pseudocontinuous arterial spin labeling to measure blood flow in the head and neck. NMR in Biomedicine. 2023;36(7):e4898. doi:10.1002/nbm.4898
2023 doi
-
[166]
Arterial spin labeling for head and neck lesion assessment: technical adjustments and clinical applications
Martín-Noguerol T, Kirsch CFE, Montesinos P, Luna A. Arterial spin labeling for head and neck lesion assessment: technical adjustments and clinical applications. Neuroradiology. 2021;63(12):1969-1983. doi:10.1007/s00234-021-02772-1
2021 doi
-
[167]
Histogram analysis of arterial spin labeling perfusion data to determine the human papillomavirus status of oropharyngeal squamous cell carcinomas
Ahn Y, Choi YJ, Sung YS, et al. Histogram analysis of arterial spin labeling perfusion data to determine the human papillomavirus status of oropharyngeal squamous cell carcinomas. Neuroradiology. 2021;63(8):1345-1352. doi:10.1007/s00234-021-02751-6
2021 doi
-
[168]
A Beginner’s Guide to Arterial Spin Labeling (ASL) Image Processing
Clement P, Petr J, Dijsselhof MBJ, et al. A Beginner’s Guide to Arterial Spin Labeling (ASL) Image Processing. Front Radio. 2022;2:929533. doi:10.3389/fradi.2022.929533
2022
-
[169]
First demonstration of arterial spin labeling on a 1.5T MR-Linac for characterizing glioblastoma perfusion dynamics
Lawrence LSP, Chugh B, Stewart J, et al. First demonstration of arterial spin labeling on a 1.5T MR-Linac for characterizing glioblastoma perfusion dynamics. In: Vol 0444. ; 2024
2024
-
[170]
MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders
Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology. 1986;161(2):401-407. doi:10.1148/radiology.161.2.3763909
1986 doi
-
[171]
Functional evaluation with intravoxel incoherent motion echo‐planar MRI in irradiated salivary glands: A correlative study with salivary gland scintigraphy
Zhang L, Murata Y, Ishida R, Ohashi I, Yoshimura R, Shibuya H. Functional evaluation with intravoxel incoherent motion echo‐planar MRI in irradiated salivary glands: A correlative study with salivary gland scintigraphy. Magnetic Resonance Imaging. 2001;14(3):223-229. doi:10.10...
2001 doi
-
[172]
Arterial spin labeling to determine tumor viability in head and neck cancer before and after treatment
Fujima N, Kudo K, Yoshida D, et al. Arterial spin labeling to determine tumor viability in head and neck cancer before and after treatment. Magnetic Resonance Imaging. 2014;40(4):920-928. doi:10.1002/jmri.24421
2014 doi
-
[173]
Head and Neck Tumors: Assessment of Perfusion-Related Parameters and Diffusion Coefficients Based on the Intravoxel Incoherent Motion Model
Sumi M, Nakamura T. Head and Neck Tumors: Assessment of Perfusion-Related Parameters and Diffusion Coefficients Based on the Intravoxel Incoherent Motion Model. AJNR Am J Neuroradiol. 2013;34(2):410-416. doi:10.3174/ajnr.A3227 46
2013 doi
-
[174]
Characterization and therapy monitoring of head and neck carcinomas using diffusion-imaging-based intravoxel incoherent motion parameters—preliminary results
Hauser T, Essig M, Jensen A, et al. Characterization and therapy monitoring of head and neck carcinomas using diffusion-imaging-based intravoxel incoherent motion parameters—preliminary results. Neuroradiology. 2013;55(5):527-536. doi:10.1007/s00234-013-1154-9
2013 doi
-
[175]
Prediction of treatment response in head and neck carcinomas using IVIM-DWI: Evaluation of lymph node metastasis
Hauser T, Essig M, Jensen A, et al. Prediction of treatment response in head and neck carcinomas using IVIM-DWI: Evaluation of lymph node metastasis. European Journal of Radiology. 2014;83(5):783-787. doi:10.1016/j.ejrad.2014.02.013
2014 doi
-
[176]
doi:10.1111/1754-9485.13626
-
[177]
Simple and Reliable Determination of Intravoxel Incoherent Motion Parameters for the Differential Diagnosis of Head and Neck Tumors
Sasaki M, Sumi M, Eida S, Katayama I, Hotokezaka Y, Nakamura T. Simple and Reliable Determination of Intravoxel Incoherent Motion Parameters for the Differential Diagnosis of Head and Neck Tumors. Jespersen SN, ed. PLoS ONE. 2014;9(11):e112866. doi:10.1371/journal.pone.0112866
2014 doi
-
[178]
Longitudinal Correlations Between Intravoxel Incoherent Motion (IVIM) and Dynamic Contrast-Enhanced (DCE) MRI During Radiotherapy in Prostate Cancer Patients
Kooreman ES, Van Pelt V, Nowee ME, Pos F, Van Der Heide UA, Van Houdt PJ. Longitudinal Correlations Between Intravoxel Incoherent Motion (IVIM) and Dynamic Contrast-Enhanced (DCE) MRI During Radiotherapy in Prostate Cancer Patients. Front Oncol. 2022;12:897130. doi:10.3389/fon...
2022
-
[179]
An optimal acquisition and post‐processing pipeline for hybrid IVIM‐DKI in head and neck
Sijtsema ND, Petit SF, Poot DHJ, et al. An optimal acquisition and post‐processing pipeline for hybrid IVIM‐DKI in head and neck. Magnetic Resonance in Med. 2021;85(2):777-789. doi:10.1002/mrm.28461
2021 doi
-
[180]
Ding Y, Hazle JD, Mohamed ASR, et al. Intravoxel incoherent motion imaging kinetics during chemoradiotherapy for human papillomavirus-associated squamous cell carcinoma of the oropharynx: preliminary results from a prospective pilot study: IVIM Kinetics during Chemoradiotherap...
2015 doi
-
[181]
Daily Intravoxel Incoherent Motion (IVIM) In Prostate Cancer Patients During MR-Guided Radiotherapy—A Multicenter Study
Kooreman ES, van Houdt PJ, Keesman R, et al. Daily Intravoxel Incoherent Motion (IVIM) In Prostate Cancer Patients During MR-Guided Radiotherapy—A Multicenter Study. Front Oncol. 2021;11. doi:10.3389/fonc.2021.705964
2021
-
[182]
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Warntjes JBM, Leinhard OD, West J, Lundberg P. Rapid magnetic resonance quantification on the brain: Optimization for clinical usage. Magnetic Resonance in Med. 2008;60(2):320-329. doi:10.1002/mrm.21635
2008 doi
-
[183]
3D T2-weighted fast spin- echo MRI sialography of the parotid gland
Sartoretti-Schefer S, Kollias S, Wichmann W, Valavanis A. 3D T2-weighted fast spin- echo MRI sialography of the parotid gland. Neuroradiology. 1999;41(1):46-51. doi:10.1007/s002340050704 47
1999 doi
-
[184]
Multiparametric magnetic resonance imaging in mucosal primary head and neck cancer: a prospective imaging biomarker study
Rumley CN, Lee MT, Holloway L, et al. Multiparametric magnetic resonance imaging in mucosal primary head and neck cancer: a prospective imaging biomarker study. BMC Cancer. 2017;17(1):475. doi:10.1186/s12885-017-3448-5
2017 doi
-
[185]
Changes in serial multiparametric MRI and FDG- PET/CT functional imaging during radiation therapy can predict treatment response in patients with head and neck cancer
Trada Y, Keall P, Jameson M, et al. Changes in serial multiparametric MRI and FDG- PET/CT functional imaging during radiation therapy can predict treatment response in patients with head and neck cancer. Eur Radiol. 2023;33(12):8788-8799. doi:10.1007/s00330-023-09843-2
2023 doi
-
[186]
Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
Kvernby S, Warntjes MJB, Haraldsson H, Carlhäll CJ, Engvall J, Ebbers T. Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS. Journal of Cardiovascular Magnetic Resonance. 2014;16(1):102. doi:10.1186/s12968-014-0102-0
2014 doi
-
[187]
Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: An accuracy and repeatability study
Fujita S, Hagiwara A, Hori M, et al. Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: An accuracy and repeatability study. Magnetic Resonance Imaging. 2019;63:235-243. doi:10.1016/j.mri.2019.08.031
2019 doi
-
[188]
Hagiwara A, Hori M, Cohen-Adad J, et al. Linearity, Bias, Intrascanner Repeatability, and Interscanner Reproducibility of Quantitative Multidynamic Multiecho Sequence for Rapid Simultaneous Relaxometry at 3 T: A Validation Study With a Standardized Phantom and Healthy Controls...
2019 doi
-
[189]
SyMRI of the Brain: Rapid Quantification of Relaxation Rates and Proton Density, With Synthetic MRI, Automatic Brain Segmentation, and Myelin Measurement
Hagiwara A, Warntjes M, Hori M, et al. SyMRI of the Brain: Rapid Quantification of Relaxation Rates and Proton Density, With Synthetic MRI, Automatic Brain Segmentation, and Myelin Measurement. Invest Radiol. 2017;52(10):647-657. doi:10.1097/RLI.0000000000000365
2017 doi
-
[190]
Investigation of synthetic MRI with quantitative parameters for discriminating axillary lymph nodes status in invasive breast cancer
Qu M, Feng W, Liu X, et al. Investigation of synthetic MRI with quantitative parameters for discriminating axillary lymph nodes status in invasive breast cancer. European Journal of Radiology. 2024;175:111452. doi:10.1016/j.ejrad.2024.111452
2024
-
[191]
Histogram analysis of MR quantitative parameters: are they correlated with prognostic factors in prostate cancer? Abdom Radiol
Chen Y, Meng T, Cao W, et al. Histogram analysis of MR quantitative parameters: are they correlated with prognostic factors in prostate cancer? Abdom Radiol. 2024;49(5):1534-1544. doi:10.1007/s00261-024-04227-6
2024 doi
-
[192]
Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: A multicenter and multivendor study
Fujita S, Gagoski B, Hwang KP, et al. Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: A multicenter and multivendor study. Magnetic Resonance in Medicine. 2024;91(5):1863-1875. doi:10.1002/mrm.29939
2024 doi
-
[193]
Synthetic MR: Physical principles, clinical implementation, and new developments
Hwang K, Fujita S. Synthetic MR: Physical principles, clinical implementation, and new developments. Medical Physics. 2022;49(7):4861-4874. doi:10.1002/mp.15686
2022 doi
-
[194]
Synthetic MRI and diffusion-weighted imaging for differentiating nasopharyngeal lymphoma from nasopharyngeal carcinoma: combination with morphological features
Zhang H, Hu L, Qin F, et al. Synthetic MRI and diffusion-weighted imaging for differentiating nasopharyngeal lymphoma from nasopharyngeal carcinoma: combination with morphological features. British Journal of Radiology. 2024;97(1159):1278-1285. doi:10.1093/bjr/tqae095
2024 doi
-
[195]
Qualitative and Quantitative Performance of Magnetic Resonance Image Compilation (MAGiC) Method: An Exploratory Analysis for Head and Neck Imaging
Konar AS, Paudyal R, Shah AD, et al. Qualitative and Quantitative Performance of Magnetic Resonance Image Compilation (MAGiC) Method: An Exploratory Analysis for Head and Neck Imaging. Cancers. 2022;14(15):3624. doi:10.3390/cancers14153624
2022 doi
-
[196]
A Radiomics Model Based on Synthetic MRI Acquisition for Predicting Neoadjuvant Systemic Treatment Response in Triple- Negative Breast Cancer
Hwang KP, Elshafeey NA, Kotrotsou A, et al. A Radiomics Model Based on Synthetic MRI Acquisition for Predicting Neoadjuvant Systemic Treatment Response in Triple- Negative Breast Cancer. Radiology: Imaging Cancer. 2023;5(4):e230009. doi:10.1148/rycan.230009
2023 doi
-
[197]
Radiation-dependent demyelination in normal appearing white matter in glioma patients, determined using quantitative magnetic resonance imaging
Ljusberg A, Blystad I, Lundberg P, Adolfsson E, Tisell A. Radiation-dependent demyelination in normal appearing white matter in glioma patients, determined using quantitative magnetic resonance imaging. Physics and Imaging in Radiation Oncology. 2023;27:100451. doi:10.1016/j.p...
2023
-
[198]
A method for sensitivity analysis of automatic contouring algorithms across different contrast weightings using synthetic magnetic resonance imaging
McCullum L, Belal Z, Floyd W, et al. A method for sensitivity analysis of automatic contouring algorithms across different contrast weightings using synthetic magnetic resonance imaging. Physics and Imaging in Radiation Oncology. 2025;35:100790. doi:10.1016/j.phro.2025.100790
2025
-
[199]
Magnetic resonance fingerprinting
Ma D, Gulani V, Seiberlich N, et al. Magnetic resonance fingerprinting. Nature. 2013;495(7440):187-192. doi:10.1038/nature11971
2013 doi
-
[200]
Technical development and In Silico implementation of SyntheticMR in head and neck adaptive radiation therapy: A prospective R‐IDEAL stage 0/1 technology development report
McCullum L, Mulder SL, West NA, et al. Technical development and In Silico implementation of SyntheticMR in head and neck adaptive radiation therapy: A prospective R‐IDEAL stage 0/1 technology development report. J Applied Clin Med Phys. 2025;26(7):e70134. doi:10.1002/acm2.70134
2025 doi
-
[201]
Technical Optimization of SyntheticMR for the Head and Neck on a 3T MR-Simulator and 1.5T MR-Linac: A Prospective R-IDEAL Stage 2a Technology Innovation Report
McCullum L, Mulder SL, West NA, et al. Technical Optimization of SyntheticMR for the Head and Neck on a 3T MR-Simulator and 1.5T MR-Linac: A Prospective R-IDEAL Stage 2a Technology Innovation Report. Published online April 10, 2025. doi:10.1101/2025.04.08.25325491
2025 doi
-
[202]
3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
Sharafi A, Zibetti MVW, Chang G, Cloos M, Regatte RR. 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T. NMR in Biomedicine. 2022;35(12):e4800. doi:10.1002/nbm.4800
2022 doi
-
[203]
Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance 49 fingerprinting (MRF)
Cohen O, Huang S, McMahon MT, Rosen MS, Farrar CT. Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance 49 fingerprinting (MRF). Magnetic Resonance in Med. 2018;80(6):2449-2463. doi:10.1002/mrm.27221
2018 doi
-
[204]
Feasibility of 3D MRI fingerprinting for rapid knee cartilage T 1 , T 2, and T 1ρ mapping at 0.55T: Comparison with 3T
De Moura HL, Monga A, Zhang X, Zibetti MVW, Keerthivasan MB, Regatte RR. Feasibility of 3D MRI fingerprinting for rapid knee cartilage T 1 , T 2, and T 1ρ mapping at 0.55T: Comparison with 3T. NMR in Biomedicine. Published online August 21, 2024:e5250. doi:10.1002/nbm.5250
2024 doi
-
[205]
AGE‐DEPENDENT CHANGES in KNEE CARTILAGE T 1 , T 2 , AND T 1 P SIMULTANEOUSLY MEASURED USING MRI FINGERPRINTING
Kijowski R, Sharafi A, Zibetti MVW, Chang G, Cloos MA, Regatte RR. AGE‐DEPENDENT CHANGES in KNEE CARTILAGE T 1 , T 2 , AND T 1 P SIMULTANEOUSLY MEASURED USING MRI FINGERPRINTING. Magnetic Resonance Imaging. 2023;57(6):1805-1812. doi:10.1002/jmri.28451
2023 doi
-
[206]
Technical overview of magnetic resonance fingerprinting and its applications in radiation therapy
Chen Y, Lu L, Zhu T, Ma D. Technical overview of magnetic resonance fingerprinting and its applications in radiation therapy. Medical Physics. 2022;49(4):2846-2860. doi:10.1002/mp.15254
2022 doi
-
[207]
Toward magnetic resonance fingerprinting for low‐field MR‐guided radiation therapy
Mickevicius NJ, Kim JP, Zhao J, Morris ZS, Hurst NJ, Glide‐Hurst CK. Toward magnetic resonance fingerprinting for low‐field MR‐guided radiation therapy. Medical Physics. 2021;48(11):6930-6940. doi:10.1002/mp.15202
2021 doi
-
[208]
CEST MR fingerprinting (CEST‐MRF) for brain tumor quantification using EPI readout and deep learning reconstruction
Cohen O, Yu VY, Tringale KR, et al. CEST MR fingerprinting (CEST‐MRF) for brain tumor quantification using EPI readout and deep learning reconstruction. Magnetic Resonance in Med. 2023;89(1):233-249. doi:10.1002/mrm.29448
2023 doi
-
[209]
Simultaneous perfusion, diffusion, T 2 *, and T 1 mapping with MR fingerprinting
Fan H, Bunker L, Wang Z, et al. Simultaneous perfusion, diffusion, T 2 *, and T 1 mapping with MR fingerprinting. Magnetic Resonance in Med. 2024;91(2):558-569. doi:10.1002/mrm.29880
2024 doi
-
[210]
Respiratory-Correlated 4-Dimensional Magnetic Resonance Fingerprinting for Liver Cancer Radiation Therapy Motion Management
Liu C, Li T, Cao P, et al. Respiratory-Correlated 4-Dimensional Magnetic Resonance Fingerprinting for Liver Cancer Radiation Therapy Motion Management. International Journal of Radiation Oncology*Biology*Physics. 2023;117(2):493-504. doi:10.1016/j.ijrobp.2023.04.015
2023 doi
-
[211]
Differences between planned and delivered dose for head and neck cancer, and their consequences for normal tissue complication probability and treatment adaptation
Heukelom J, Kantor ME, Mohamed ASR, et al. Differences between planned and delivered dose for head and neck cancer, and their consequences for normal tissue complication probability and treatment adaptation. Radiotherapy and Oncology. 2020;142:100-106. doi:10.1016/j.radonc.2019.07.034
2020 doi
-
[212]
LOW‐RANK inversion reconstruction for THROUGH‐ PLANE accelerated radial MR fingerprinting applied to relaxometry at 0
Mickevicius NJ, Glide‐Hurst CK. LOW‐RANK inversion reconstruction for THROUGH‐ PLANE accelerated radial MR fingerprinting applied to relaxometry at 0. 35 T. Magnetic Resonance in Med. 2022;88(2):840-848. doi:10.1002/mrm.29244
2022 doi
-
[213]
Technical feasibility of magnetic resonance fingerprinting on a 1.5T MRI-linac
Bruijnen T, Van Der Heide O, Intven MPW, et al. Technical feasibility of magnetic resonance fingerprinting on a 1.5T MRI-linac. Phys Med Biol. 2020;65(22):22NT01. doi:10.1088/1361-6560/abbb9d
2020 doi
-
[214]
Markov models for clinical decision‐making in radiation oncology: A systematic review
McCullum LB, Karagoz A, Dede C, et al. Markov models for clinical decision‐making in radiation oncology: A systematic review. J Med Imag Rad Onc. Published online May 20, 2024:1754-9485.13656. doi:10.1111/1754-9485.13656
2024
-
[215]
Hosseinian S, Hemmati M, Dede C, et al. Cluster-Based Toxicity Estimation of Osteoradionecrosis Via Unsupervised Machine Learning: Moving Beyond Single Dose- Parameter Normal Tissue Complication Probability by Using Whole Dose-Volume Histograms for Cohort Risk Stratification. ...
2024 doi
-
[216]
Optimal timing of re- planning for head and neck adaptive radiotherapy
Gan Y, Langendijk JA, Oldehinkel E, Lin Z, Both S, Brouwer CL. Optimal timing of re- planning for head and neck adaptive radiotherapy. Radiotherapy and Oncology. 2024;194:110145. doi:10.1016/j.radonc.2024.110145
2024
-
[217]
Nosrat F, Dede C, McCullum LB, et al. Personalized Rescheduling of Adaptive Organ-at-Risk-Sparing Radiation Therapy for Head and Neck Cancer under Re-planning Resource Constraints: A Novel Application of Markov Decision Processes. Published online April 2, 2024. doi:10.1101/20...
2024 doi
-
[218]
Exploring approaches for predictive cancer patient digital twins: Opportunities for collaboration and innovation
Stahlberg EA, Abdel-Rahman M, Aguilar B, et al. Exploring approaches for predictive cancer patient digital twins: Opportunities for collaboration and innovation. Front Digit Health. 2022;4:1007784. doi:10.3389/fdgth.2022.1007784
2022
-
[219]
Digital Twins for Radiation Oncology
Jensen J, Deng J. Digital Twins for Radiation Oncology. In: Companion Proceedings of the ACM Web Conference 2023. ACM; 2023:989-993. doi:10.1145/3543873.3587688
2023
-
[220]
Surveillance imaging for patients with head and neck cancer treated with definitive radiotherapy: A partially observed Markov decision process model
Ng SP, Ajayi T, Schaefer AJ, et al. Surveillance imaging for patients with head and neck cancer treated with definitive radiotherapy: A partially observed Markov decision process model. Cancer. 2020;126(4):749-756. doi:10.1002/cncr.32597
2020 doi
-
[221]
Usefulness of surveillance imaging in patients with head and neck cancer who are treated with definitive radiotherapy
Ng SP, Pollard C, Berends J, et al. Usefulness of surveillance imaging in patients with head and neck cancer who are treated with definitive radiotherapy. Cancer. 2019;125(11):1823-1829. doi:10.1002/cncr.31983
2019 doi
-
[222]
A Review of Intelligent Subway Tunnels Based on Digital Twin Technology
Zhao Y, Liu Y, Mu E. A Review of Intelligent Subway Tunnels Based on Digital Twin Technology. Buildings. 2024;14(8):2452. doi:10.3390/buildings14082452
2024 doi
-
[223]
Utilizing Artificial Intelligence for Head and Neck Cancer Outcomes Prediction From Imaging
Chinnery T, Arifin A, Tay KY, et al. Utilizing Artificial Intelligence for Head and Neck Cancer Outcomes Prediction From Imaging. Can Assoc Radiol J. 2021;72(1):73-85. doi:10.1177/0846537120942134
2021 doi
-
[224]
Adaptive radiotherapy for head and neck cancer
Morgan HE, Sher DJ. Adaptive radiotherapy for head and neck cancer. Cancers Head Neck. 2020;5(1):1. doi:10.1186/s41199-019-0046-z
2020 doi
-
[225]
Adaptive radiation therapy for head and neck cancer
Juloori A, Ward MC, Joshi NP, et al. Adaptive radiation therapy for head and neck cancer. ARO. Published online September 1, 2015:12-17. doi:10.37549/ARO1073
2015 doi
-
[228]
Keall PJ, Nguyen DT, O’Brien R, et al. Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy? International Journal of Radiation Oncology*Bi...
2018 doi
-
[479]
doi:10.1111/j.1442-2050.2009.01037.x
2009
-
[642]
doi:10.1002/mp.13927
Reviewed August 6, 2026 · model on record in the stance chip above.
Discussion (0). Sign in to comment.