pith. sign in

arxiv: 1405.7402 · v1 · pith:APWWOGLXnew · submitted 2014-05-28 · ⚛️ physics.acc-ph

Visible-light beam size monitors using synchrotron radiation at CESR

classification ⚛️ physics.acc-ph
keywords beamsizecesrmeasuremonitorsizesdirectimaging
0
0 comments X
read the original abstract

A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be measured with a resolution of approximately 5 um. To measure larger beam size (> 500 um), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the pi-polarized component of SR, a small vertical beam size (~70 um) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.

This paper has not been read by Pith yet.

discussion (0)