Pith. sign in

REVIEW

Precision Fe Kalpha and Fe Kbeta Line Spectroscopy of the Seyfert 1.9 Galaxy NGC 2992 with Suzaku

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv astro-ph/0609581 v1 pith:BSTI65T5 submitted 2006-09-20 astro-ph

classification astro-ph
keywords linenarrowkalphakbetacontinuumlinesbroadcomplex
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We present detailed time-averaged X-ray spectroscopy in the 0.5--10 keV band of the Seyfert~1.9 galaxy NGC 2992 with the Suzaku X-ray Imaging Spectrometers (XIS). We model the complex continuum in detail. There is an Fe K line emission complex that we model with broad and narrow lines and we show that the intensities of the two components are decoupled at a confidence level >3sigma. The broad Fe K line has an EW of 118 (+32,-61) eV and could originate in an accretion disk (with inclination angle greater than ~30 degrees). The narrow Fe Kalpha line has an EW of 163 (+47,-26) eV and is unresolved FWHM <4090 km/s) and likely originates in distant matter. The absolute flux in the narrow line implies that the column density out of the line-of-sight could be much higher than measured in the line-of-sight, and that the mean (historically-averaged) continuum luminosity responsible for forming the line could be a factor of several higher than that measured from the data. We also detect the narrow Fe Kbeta line with a high signal-to-noise ratio and describe a new robust method to constrain the ionization state of Fe responsible for the Fe Kalpha and Fe Kbeta lines that does not require any knowledge of possible gravitational and Doppler energy shifts affecting the line energies. For the distant line-emitting matter (e.g. the putative obscuring torus) we deduce that the predominant ionization state is lower than Fe VIII (at 99% confidence), conservatively taking into account residual calibration uncertainties in the XIS energy scale and theoretical and experimental uncertainties in the Fe K fluorescent line energies. From the limits on a possible Compton-reflection continuum it is likely that the narrow Fe Kalpha and Fe Kbeta lines originate in a Compton-thin structure.

Discussion (0). Continue with ORCID to comment.

Pith tools