Pith. sign in

REVIEW 2 cited by

Phase Lags and Coherence of X-Ray Variability in Black Hole Candidates

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv astro-ph/9512019 v1 pith:EJUAKPVG submitted 1995-12-05 astro-ph

classification astro-ph
keywords lagsphasecloudinputcoherencecomptontimefourier
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The ``low'' (hard or ``non-thermal'') state of black hole candidates is sometimes modelled via an optically thick, hot Compton cloud that obscures a softer input source such as an accretion disk. In these models the observed output spectra consist entirely of photons reprocessed by the cloud, making it difficult to extract information about the input spectra. Recently Miller (1995) has argued that the Fourier phase (or time) lag between hard and soft X-ray photons in actuality represents the phase lags intrinsic to the input source, modulo a multiplicative factor. The phase lags thus would be a probe of the input photon source. In this paper we examine this claim and find that, although true for the limited parameter space considered by Miller, the intrinsic phase lag disappears whenever the output photon energy is much greater than the input photon energy. The remaining time lags represent a ``shelf'' due to differences between mean diffusion times across the cloud. As pointed out by Miller, the amplitude of this shelf -- which is present even when the intrinsic time lags remain -- is indicative of the size and temperature of the Compton cloud and is a function of the two energies being compared. However, we find that with previous instruments such as Ginga the shelf, if present, was likely obscured by counting noise. A more sensitive measure of Compton cloud parameters may be obtainable from the coherence function, which is derived from the amplitude of the Fourier cross power spectral density. This function has been seen to exponentially decrease at high Fourier frequencies in Cygnus X-1. Coherence loss is characteristic of Compton clouds that undergo large variations of size and/or temperature on time scales longer than about 10 seconds. We argue that observing phase lags and coherence

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. OpenAlex reports about 62 citations worldwide. Full citation record

  1. Discovery of a quasi-periodic oscillation non-harmonically related to the Type-C QPO in the hard intermedidate state of MAXI J1820+070

    astro-ph.HE 2026-06 unverdicted novelty 7.0 of 10

    Detection of a non-harmonic QPO precursor to Type-B in the HIMS of MAXI J1820+070 using NICER timing data.

  2. Quasi-Periodic Oscillations due to radiative feedback mechanism between the disc and corona

    astro-ph.HE 2025-07 conditional novelty 6.0 of 10

    A disc-corona radiative feedback loop with a time delay produces QPOs at 1/(tau_A+tau_B), and its analytic power spectrum fits AstroSat data of two black hole binaries.

Pith tools