Extended formalism for simulating compound refractive lens-based x-ray microscopes
classification
⚛️ physics.optics
keywords
imagingformalismx-rayaberrationaccountanalysisanalyticalaperture
read the original abstract
We present a comprehensive formalism for the simulation and optimisation of CRLs in both condensing and full-field imaging configurations. The approach extends ray transfer matrix analysis to account for x-ray attenuation by the lens material. Closed analytical expressions for critical imaging parameters such as numerical aperture, vignetting, chromatic aberration and focal length are provided for both thin- and thick-lens imaging geometries.
This paper has not been read by Pith yet.