Core claim
With both GEM foils operated at 255 V and the anode wire grid supplying most of the gain, double-layer staggered GEMs reduce the ion back-flow ratio to approximately 0.58 percent at an effective gain of about 2500 while delivering an energy resolution of about 10 percent, as verified by direct measurement in the prototype after parameter optimization from simulation.
What carries the argument
The hybrid GEM-plus-anode-wire readout, where the GEM foils at low voltage absorb ions and the wire grid provides the bulk of electron multiplication.
If this is right
- Continuous TPC readout becomes feasible without the dead time introduced by switching a gated grid.
- Ion back-flow can be held below one percent while most of the gain comes from a stable, long-lifetime wire grid.
- Energy resolution around 10 percent is maintained at the tested gain with the chosen low GEM voltages.
- The combination exploits the ion-blocking property of GEMs together with the high-voltage stability of anode wires.
Where Pith is reading between the lines
- If the geometry scales without increasing ion transmission, the same hybrid layout could be applied to larger TPCs.
- Similar low-voltage GEM plus wire combinations might reduce ion feedback in other gas-based detectors that currently rely on gating.
- Further tests at different gas mixtures or higher overall gains would show whether the 0.58 percent level holds beyond the reported conditions.
Load-bearing premise
The Garfield++ and finite-element simulations correctly predict the real ion and electron transmission through the actual geometry and voltage settings of the prototype.
What would settle it
A measurement in the same prototype that finds an ion back-flow ratio well above 0.58 percent at 255 V GEM settings, staggered alignment, and effective gain near 2500 would falsify the reported suppression.
Figures
read the original abstract
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG) leads to a dead time and also limit the readout efficiency of the TPC. Gas Electron Multiplier (GEM) foil provides a possibility of continuous readout for TPC, which can suppress IBF efficiently while keeping stable gain. A prototype chamber including two layers of GEM foils and anode wires has been built to combine both advantages from GEM and anode wire. Using Garfield++ and the finite element analysis (FEA) method, simulations of the transmission processes of electrons and ions are performed and results on absorption ratio of ions, gain and IBF ratio are obtained. The optimized parameters from simulation are then applied to the prototype chamber to test the IBF and other performances. Both GEM foils are run at low voltage (255V), while most of the gain is provided by the anode wire. The measurement shows that the IBF ratio can be suppressed to ~0.58% with double-layer GEM foils (staggered) at an effective gain about 2500 with an energy resolution about 10%.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript reports on a hybrid TPC readout using double-layer GEM foils (staggered alignment) plus an anode wire grid. Garfield++ and FEA simulations are used to optimize GEM voltages (255 V) and geometry so that most of the gain occurs at the wires; these parameters are then applied to a physical prototype. The central experimental result is an IBF ratio of ~0.58 % at effective gain ~2500 with ~10 % energy resolution.
Significance. If the measured IBF suppression holds, the design offers a route to continuous TPC readout without the dead-time penalty of a gated grid, which is relevant for high-rate experiments. The work supplies a concrete, simulation-guided prototype benchmark that can be compared with other GEM or Micromegas solutions.
major comments (2)
- [Abstract] Abstract and results: the headline IBF value of ~0.58 % is given without reported uncertainties, raw counting statistics, or a description of the ion-current measurement technique (e.g., how the back-flowing ions are collected and normalized to the primary ionization). This directly affects the reliability of the central experimental claim.
- [Prototype measurements] Prototype section: no table or figure presents the measured IBF ratio together with its uncertainty or the corresponding effective-gain and energy-resolution values; the absence of these data makes it impossible to judge whether the quoted 0.58 % is statistically distinguishable from other operating points.
minor comments (2)
- The text should state the precise definition of “effective gain” used for the wire-grid stage and how it was extracted from the prototype data.
- Clarify whether the staggered alignment of the two GEM foils was verified optically or by X-ray imaging after assembly, and report the achieved alignment tolerance.
Simulated Author's Rebuttal
We thank the referee for the constructive comments. We address the two major points below and will revise the manuscript to improve the presentation of the experimental results.
read point-by-point responses
-
Referee: [Abstract] Abstract and results: the headline IBF value of ~0.58 % is given without reported uncertainties, raw counting statistics, or a description of the ion-current measurement technique (e.g., how the back-flowing ions are collected and normalized to the primary ionization). This directly affects the reliability of the central experimental claim.
Authors: We agree that the abstract and results section would benefit from these details. In the revised manuscript we will add a concise description of the ion-current measurement (back-flowing ions collected on the cathode and read out with a picoammeter, normalized to the primary ionization current measured in the absence of amplification) together with the statistical uncertainty derived from repeated measurements. The headline IBF value will be updated to include the uncertainty. revision: yes
-
Referee: [Prototype measurements] Prototype section: no table or figure presents the measured IBF ratio together with its uncertainty or the corresponding effective-gain and energy-resolution values; the absence of these data makes it impossible to judge whether the quoted 0.58 % is statistically distinguishable from other operating points.
Authors: We acknowledge the omission. The revised manuscript will contain a new table (and, if space permits, an accompanying figure) that tabulates the measured IBF ratio, effective gain, and energy resolution at the optimized point, each with its associated uncertainty. This will allow direct assessment of statistical significance and comparison with other operating conditions. revision: yes
Circularity Check
No significant circularity: experimental measurement after simulation-guided setup
full rationale
The paper's central claim is a direct experimental measurement of IBF ratio (~0.58%) on a physical prototype chamber after applying simulation-selected parameters (255 V GEM bias, staggered alignment). Simulations (Garfield++ and FEA) are used only to choose operating points and are not invoked to compute or fit the reported IBF value; the headline result is obtained from prototype data, not from any equation or parameter that reduces to the same dataset by construction. No self-definitional steps, fitted-input predictions, or load-bearing self-citations appear in the derivation chain.
Axiom & Free-Parameter Ledger
free parameters (2)
- GEM operating voltage =
255 V
- target effective gain =
2500
axioms (1)
- domain assumption Garfield++ and finite-element analysis accurately model electron and ion transmission through the GEM-wire geometry.
Reference graph
Works this paper leans on
-
[1]
J.N. Marx and D.R. Nygren, The time projection chamber, Phys. Today 31 (10) (1978), 46-53
work page 1978
-
[2]
Sauli, GEM: a new concept for electron amplification in gas detectors, Nucl
F. Sauli, GEM: a new concept for electron amplification in gas detectors, Nucl. Instr. Meth. A 386 (1997), 531-534
work page 1997
-
[3]
Bouclier, et al., New observations with the gas electron mul- tiplier (GEM), Nucl
R. Bouclier, et al., New observations with the gas electron mul- tiplier (GEM), Nucl. Instr. Meth. A 396 (1997), 50-56
work page 1997
-
[4]
Lippmann, A continuous read-out TPC for the ALICE up- grade, Nucl
C. Lippmann, A continuous read-out TPC for the ALICE up- grade, Nucl. Instr. Meth. A 824 (2016), 543-547
work page 2016
-
[5]
P. Gasik, et al., Building a large-area GEM-based readout cham- ber for the upgrade of the ALICE TPC, Nucl. Instr. Meth. A 845 (2017), 222-225
work page 2017
-
[6]
S. Aiola, et al. , Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection cham- ber, Nucl. Instr. Meth. A, 834 (2016), 149-157
work page 2016
-
[7]
Shen, et al., MWPC prototyping and performance test for the STAR inner TPC upgrade, Nucl
F. Shen, et al., MWPC prototyping and performance test for the STAR inner TPC upgrade, Nucl. Instr. Meth. A 896 (2018), 90- 95
work page 2018
-
[8]
Xu Wang, et al. , Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC up- grade, Nucl. Instr. Meth. A 59 (2017), 90-94
work page 2017
-
[9]
S. Yang, et al. , Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector, Nucl. Instr. Meth. A 785 (2015), 33-39
work page 2015
-
[10]
Berger, et al., A large ungated TPC with GEM amplification, Nucl
M. Berger, et al., A large ungated TPC with GEM amplification, Nucl. Instr. Meth. A 869 (2017), 180-204
work page 2017
-
[11]
H. Natal da Luz, et al., Ion backflow studies with a triple-GEM stack with increasing hole pitch, JINST 13 (2018), P07025
work page 2018
-
[12]
O. Bouianov, et al. , Progress in GEM simulation, Nucl. Instr. Meth. A 450 (2000), 277-287
work page 2000
-
[13]
P. Gasik, et al., Charge density as a driving factor of discharge formation in GEM-based detectors, Nucl. Instr. Meth. A 870 (2017), 116-122
work page 2017
-
[14]
S.Bachmann, et al., Charge amplification and transfer processes in the gas electron multiplier, Nucl. Instr. Meth. A 438 (1999), 376-408
work page 1999
-
[15]
Sauli, The gas electron multiplier (GEM): Operating princi- ples and applications, Nucl
F. Sauli, The gas electron multiplier (GEM): Operating princi- ples and applications, Nucl. Instr. Meth. A 805 (2016), 2-24
work page 2016
-
[16]
M ¨ormann, et al., Evaluation and reduction of ion back-flow in multi-GEM detectors, Nucl
D. M ¨ormann, et al., Evaluation and reduction of ion back-flow in multi-GEM detectors, Nucl. Instr. Meth. A 516 (2004), 315- 326
work page 2004
-
[17]
Betts, et al., Studies of several wire and pad configurations for the STAR TPC, STAR Note 0263
W. Betts, et al., Studies of several wire and pad configurations for the STAR TPC, STAR Note 0263
-
[18]
Technical Design Report for the Upgrade of the ALICE Time Projection Chamber, CERN-LHCC-2013-020, ALICE-TDR- 016
work page 2013
-
[19]
Jeanneau, et al., Ion back-flow gating in a micromegas device, Nucl
F. Jeanneau, et al., Ion back-flow gating in a micromegas device, Nucl. Instr. Meth. A 623 (2010), 94-96
work page 2010
-
[20]
Zhangbu Xu, et al., GEM based TRD for Identifying electrons at EIC, R&D proposal for an Endcap TOF and TRD for Identifying electrons at EIC, 2014
work page 2014
-
[21]
B¨ohmer, et al., Simulation of space-charge effects in an un- gated GEM-based TPC, Nucl
F.V . B¨ohmer, et al., Simulation of space-charge effects in an un- gated GEM-based TPC, Nucl. Instr. Meth. A 719 (2013), 101- 108
work page 2013
-
[22]
S. Rossegger and J. Thomas, Space-charge e ffects in the ALICE TPC: a comparison between expected ALICE performance and current results from the STAR TPC, ALICE Internal Note, 2011, ALICE-INT-2010-017
work page 2011
- [23]
-
[24]
S.Rossegger, B.Schnizer and W.Riegler, Analytical solutions for space charge fields in TPC drift volumes, Nucl. Instr. Meth. A 632 (2011), 52-58. 9
work page 2011
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.