Self-Alignment of a Large-Area Dual-Atom-Interferometer Gyroscope Using Parameter Decoupled Phase Seeking Calibrations
read the original abstract
We realize a Mach-Zehnder-type dual-atom-interferometer gyroscope with an interrogation arm of 40 cm length and the interference area up to 1.2 cm$^2$. The precise angular alignment of the large-scale separated Raman lasers is demonstrated by seeking the phase intersection of Ramsey-Bord$\acute{e}$ interferometers after the gravity effect is compensated and by decoupling the velocity dependent crosstalk phase shifts, and applied to build the Mach-Zehnder atom interferometer. Then a compact inertial rotation sensor is realized based on dual large-area Mach-Zehnder atom interferometers by precisely aligning the large-scale separated Raman lasers, in which the coherence is well preserved and the common noise is differentially suppressed. The sensor presents a sensitivity of $1.5\times10^{-7}$ rad/s/Hz$^{1/2}$, and a stability of $9.5\times10^{-10}$ rad/s at 23000 s. The absolute rotation measurement is carried out by adjusting the atomic velocity which corresponds to modulating the scale factor.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.