pith. sign in

arxiv: 1907.05352 · v1 · pith:JYFAVJE3new · submitted 2019-07-11 · ⚛️ physics.plasm-ph · physics.app-ph· physics.ins-det

A new compact, portable 2-LTD-brick x-pinch driver at the Idaho Accelerator Center: design, fabrication, testing and x-ray performance

Pith reviewed 2026-05-24 22:53 UTC · model grok-4.3

classification ⚛️ physics.plasm-ph physics.app-phphysics.ins-det
keywords x-pinch driverLTD bricksportable generatorx-ray sourceplasma diagnosticscurrent rise ratecompact driverwarm dense matter
0
0 comments X

The pith

Compact 2-LTD-brick driver supplies 185 kA at 80 kV with 220 ns rise time into a wire load

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The paper reports the design, fabrication, and initial testing of a compact portable x-pinch driver assembled from two slow LTD bricks that together contain four 140 nF capacitors storing up to 2.8 kJ. When charged to 80 kV the driver produces a measured 185 kA peak current into a short nickel-wire load with a 220 ns 10-90 percent rise time and a total internal inductance of 60 nH. A revised RLC-circuit model then projects that charging the same unit to 100 kV will deliver 180 kA with a 150 ns rise time, yielding a current rise rate of 1.2 kA/ns. The resulting oil-free package is intended to serve as a movable bright x-ray backlighter for exploding-wire and warm-dense-matter experiments.

Core claim

The 2-LTD-brick driver, described by a simple RLC circuit, achieves 185 kA peak current with 220 ns rise time at 80 kV into a short Ni-wire load and is projected by the model to reach 180 kA with 150 ns rise time at 100 kV, supplying a 1.2 kA/ns current rate into an x-pinch load while remaining compact and oil-free.

What carries the argument

Two slow LTD bricks combined into one solid unit that forms the driving RLC circuit for the x-pinch load

If this is right

  • At full 100 kV charge the driver supplies 180 kA with 150 ns rise time and a 1.2 kA/ns current rate into the x-pinch load.
  • The x-pinch radiation source can image exploding wires placed in a separate high-voltage pulser to study warm dense matter.
  • The oil-free compact package can be relocated to any location as a diagnostic tool.
  • The source supplies bright fast small x-pinch radiation needed for plasma physics, biology, and industry applications.

Where Pith is reading between the lines

These are editorial extensions of the paper, not claims the author makes directly.

  • A portable unit of this type could enable on-site x-ray backlighting diagnostics in field plasma experiments that cannot use large fixed facilities.
  • Pairing the driver with other high-voltage equipment may allow combined loading and imaging setups for warm-dense-matter research.
  • The measured inductance and brick arrangement could serve as a starting point for scaling to still smaller or faster portable x-pinch drivers.

Load-bearing premise

The measured 60 nH internal inductance and the simple RLC model will continue to describe driver behavior accurately at the higher 100 kV charge level and with an actual x-pinch load.

What would settle it

Measure the current waveform through a real x-pinch load at 100 kV charge voltage and check whether the observed peak current is near 180 kA and the 10-90 percent rise time is near 150 ns.

read the original abstract

We propose to construct a compact and portable x-pinch driver with x-ray radiation performance, comparable to standard x-pinch drivers. Such a new x-pinch driver was recently designed, fabricated and tested at the Idaho Accelerator Center. The generator is based on two slow LTD bricks combined into one solid unit, and can be described by a simple RLC circuit with four fast 140-nF, 100-kV capacitors that store up to 2.8 kJ. The test data reveals that when charged to 80 kV, the driver supplies 185-kA peak-current into a short Ni-wire load with 220-ns, 10-90%, rise time. The total internal inductance of our driver was measured to be about 60 nH. The revised driver model shows that when fully charged to 100 kV, the driver will supply 180-kA peak-current with 150-ns rise-time into the x-pinch load. The corresponding current rise rate is about 1.2 kA/ns. To prove the driver x-pinch efficiency and to estimate the x-ray radiation performance, we could, for example, image an exploding wires, placed in a separate HV pulser, with our x-pinch x-ray radiation source. The study of exploding wires helps to understand the behavior of a warm dense matter, and our x-pinch driver can be part of the diagnostics needed for this study which is currently under progress at the IAC. Our driver contains no oil inside, is very compact and portable, and can be easily relocated to practically anywhere, which makes it an ideal backlighting diagnostic tool in many areas of plasma physics, biology, and industry where a bright, fast, and small x-pinch radiation source is required.

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, simulated authors' rebuttal, and a circularity audit. Tearing a paper down is the easy half of reading it; the pith above is the substance, this is the friction.

Referee Report

1 major / 0 minor

Summary. The paper presents the design, fabrication, and testing of a compact portable x-pinch driver based on two slow LTD bricks containing four 140-nF, 100-kV capacitors. Direct electrical tests at 80 kV charge into a short Ni-wire load yield 185 kA peak current with 220 ns (10-90%) rise time and a measured total internal inductance of ~60 nH. A revised RLC circuit model is then used to predict 180 kA peak current with 150 ns rise time (1.2 kA/ns) at 100 kV into an x-pinch load. The driver is oil-free and portable; x-ray performance is proposed but not demonstrated.

Significance. If the 100 kV electrical performance is validated with an actual x-pinch load, the work would supply a compact, portable high-current driver suitable for x-ray backlighting diagnostics in warm dense matter and plasma physics experiments. The direct 80 kV measurements provide a concrete data point, but the extrapolation depends on unverified model assumptions.

major comments (1)
  1. [Abstract] Abstract: the revised driver model prediction of 180 kA peak current with 150 ns rise time at 100 kV into the x-pinch load rests on unspecified load inductance and resistance values that differ from the short Ni-wire load used in the 80 kV test (185 kA, 220 ns). No breakdown of the 60 nH total internal inductance into driver vs. load components is given, and it is not demonstrated that the constant-L RLC model reproduces the measured 80 kV waveform.

Simulated Author's Rebuttal

1 responses · 0 unresolved

We thank the referee for their careful reading and constructive feedback on our manuscript. The major comment identifies areas where additional detail on the RLC model would strengthen the presentation; we address this directly below and will incorporate the requested clarifications in a revised version.

read point-by-point responses
  1. Referee: [Abstract] Abstract: the revised driver model prediction of 180 kA peak current with 150 ns rise time at 100 kV into the x-pinch load rests on unspecified load inductance and resistance values that differ from the short Ni-wire load used in the 80 kV test (185 kA, 220 ns). No breakdown of the 60 nH total internal inductance into driver vs. load components is given, and it is not demonstrated that the constant-L RLC model reproduces the measured 80 kV waveform.

    Authors: We agree that the abstract (and supporting text) would benefit from explicit model parameters and validation. The 60 nH figure is the total inductance extracted from the shorted Ni-wire shot at 80 kV. For the 100 kV x-pinch prediction we employed a lower load inductance consistent with typical x-pinch geometry together with a small series resistance; these values were not stated. In the revision we will (i) report the exact load L and R used for the 100 kV case, (ii) provide a breakdown of the measured 60 nH into driver and load contributions, and (iii) include a direct overlay of the constant-L RLC simulation against the recorded 80 kV current waveform to confirm model fidelity. These additions will be placed in both the abstract and a new short modeling subsection. revision: yes

Circularity Check

0 steps flagged

No significant circularity; claims rest on direct measurements and standard RLC extrapolation

full rationale

The paper reports experimental results from an 80 kV test into a short Ni-wire load (185 kA peak, 220 ns rise time) and a measured total internal inductance of ~60 nH. The 100 kV prediction (180 kA, 150 ns into x-pinch load) is stated as output from a 'revised driver model' described as a simple RLC circuit, but the provided text contains no equations, no fitted parameters renamed as predictions, no self-citations, and no self-definitional steps where a claimed derivation reduces to its own inputs by construction. The derivation chain is therefore self-contained against external benchmarks of measurement and circuit modeling.

Axiom & Free-Parameter Ledger

0 free parameters · 0 axioms · 0 invented entities

This is an experimental hardware paper reporting construction and electrical testing of a pulsed-power device. No free parameters, mathematical axioms, or invented physical entities are introduced.

pith-pipeline@v0.9.0 · 5873 in / 1253 out tokens · 22334 ms · 2026-05-24T22:53:21.470504+00:00 · methodology

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Reference graph

Works this paper leans on

72 extracted references · 72 canonical work pages

  1. [1]

    Zakharov, G

    M. Zakharov, G. V. Ivanenkov, A. A. Kolomenskii, S. A. Pikuz, A. I. Samokhin, and J. Ullschmeid, Sov. Tech. Phys. Lett., vol. 8, p. 456, 1982

  2. [2]

    High-luminosity monochromatic x-ray backlighting using an incoherent plasma source to study extremely dense plasmas (invited),

    S. A. Pikuz, T. A. Shelkovenko, V. M. Romanova, D. A. Hammer, A. Ya. Faenov, V. A. Dyakin, and T. A. Pikuz, "High-luminosity monochromatic x-ray backlighting using an incoherent plasma source to study extremely dense plasmas (invited)," Rev. Sci. Instrum., vol. 68, p. 740, 1997

  3. [3]

    Studies of plasma formation from exploding wires and multiwire arrays using x-ray backlighting,

    T. A. Shelkovenko, S. A. Pikuz, A. R. Mingaleev, and D. A. Hammer, "Studies of plasma formation from exploding wires and multiwire arrays using x-ray backlighting," Rev. Sci. Instrum., vol. 70, p. 667, 1999

  4. [4]

    Density measurements in exploding wire-initiated plasmas using tungsten wires,

    S. A. Pikuz, T. A. Shelkovenko, A. R. Mingaleev, D. A. Hammer, and H. P. Neves, "Density measurements in exploding wire-initiated plasmas using tungsten wires," Phys. Plasmas, vol. 6, p. 4272, 1999

  5. [5]

    Multiphase Foamlike Structure of Exploding Wire Cores,

    S. A. Pikuz, T. A. Shelkovenko, D. B. Sinars, J. B. Greenly, Y. S. Dimant, and D. A. Hammer, "Multiphase Foamlike Structure of Exploding Wire Cores," Phys. Rev. Lett., vol. 83, p. 4313–4316, 1999

  6. [6]

    X-pinch Applications In X-ray Radiography and Design of Compact Table-Top X-Pinch Device,

    R. Zhang, T. Zhao, X. Zou, X. Zhu, and X. Wang, "X-pinch Applications In X-ray Radiography and Design of Compact Table-Top X-Pinch Device," in Power Modulator and High Voltage Conference (IPMHVC), 2010 IEEE International

  7. [7]

    Point -projection x-ray radiography using an X pinch as the radiation source,

    T. A. Shelkovenko, D. B. Sinars, S. A. Pikuz, K. M. Chandler, and D. A. Hammer, "Point -projection x-ray radiography using an X pinch as the radiation source," Rev. Sci. Instrum., vol. 72, p. 667, 2001

  8. [8]

    Experiments measuring the initial energy deposition, expansion rates and morphology of exploding wires with about 1 kA/wire,

    D. B. Sinars, Min Hu, K. M. Chandler, T. A. Shelkovenko, S. A. Pikuz, J. B. Greenly, D. A. Hammer, and B. R. Kusse, "Experiments measuring the initial energy deposition, expansion rates and morphology of exploding wires with about 1 kA/wire," Phys. Plasmas 8, 216 (2001)., vol. 8, no. 1, p. 216, 2001

  9. [9]

    X ‐ Pinch And Its Applications In X‐ray Radiograph,

    Xiaobing Zou, Xinxin Wang, Rui Liu, Tong Zhao, Naigong Zeng, Yongchao Zhao, and Yanqiang Du, "X ‐ Pinch And Its Applications In X‐ray Radiograph," in AIP Conf. Proc. , 2009

  10. [10]

    Microexplosion of a Hot Point in an X-Pinch Constriction,

    G. V. Ivanenkov, S. A. Pikuz, D. B. Sinars, V. Stepnievski, D. A. Hammer, and T. A. Shelkovenko, "Microexplosion of a Hot Point in an X-Pinch Constriction," Plasma Physics Reports , vol. 26, no. 10, pp. 868-874, 2000

  11. [11]

    Formation, Cascade Development, and Rupture of the X-Pinch Neck,

    G. V. Ivanenkov, S. A. Pikuza, T. A. Shelkovenko, J. Greenly, D. B. Sinars, and D. A. Hammer, "Formation, Cascade Development, and Rupture of the X-Pinch Neck," Journal of Experimental and Theoretical Physics, vol. 91, no. 3, pp. 469-478, 2000

  12. [12]

    Radiographic and spectroscopic studies of X-pinch plasma implosion dynamics and x-ray burst emission characteristics,

    T. A. Shelkovenko, D. B. Sinars, S. A. Pikuz, and D. A. Hammer, "Radiographic and spectroscopic studies of X-pinch plasma implosion dynamics and x-ray burst emission characteristics," Phys. Plasmas, vol. 8, no. 4, p. 1305, Apr. 2001

  13. [13]

    High Energy Density Z-Pinch Plasma Conditions with Picosecond Time Resolution,

    S. A. Pikuz, D. B. Sinars, T. A. Shelkovenko, K. M. Chandler, D. A. Hammer, G. V. Ivanenkov, W. Stepniewski, and I. Yu. Skobelev, "High Energy Density Z-Pinch Plasma Conditions with Picosecond Time Resolution," Phys. Rev. Let. , vol. 89, no. 3, p. 035003, 2002

  14. [14]

    The Imaging of Z‐Pinches Using X‐Pinch Backlighting,

    J. D. Douglass, J. B. Greenly, D. A. Hammer, R. D. McBride, S. A. Pikuz, and T. A. Shelkovenko, "The Imaging of Z‐Pinches Using X‐Pinch Backlighting," in DENSE Z-PINCHES: 6th International Conference on Dense Z-Pinches, 25-28 July 2005

  15. [15]

    Effect of core-corona plasma structure on seeding of instabilities in wire array z-pinches,

    S.V.Lebedev, F.N.Beg, S.N.Bland, J.P.Chittenden, A.E.Dangor, M.G.Haines, S.A.Pikuz, T.A.Shelkovenko, "Effect of core-corona plasma structure on seeding of instabilities in wire array z-pinches," Phys. Rev. Lett., vol. 85, no. 1, p. 98, 2000

  16. [16]

    X-ray backlighting of wire array Z-pinch implosions using X pinch,

    S. V. Lebedev, F. N. Beg, S. N. Bland, J. P. Chittenden, A. E. Dangor, M. G. Haines, M. Zakaullah, S.A. Pikuz, T.A. Shelkovenko, and D.A. Hammer, "X-ray backlighting of wire array Z-pinch implosions using X pinch," Rev. Sci. Instrum., vol. 72, no. 1, p. 671, 2001

  17. [17]

    Small size X -pinch radiation source for application to phase-contrast x-ray radiography of biological specimens,

    Byung Moo Song, S. A. Pikuz, T. A. Shelkovenko, and D. A. Hammer, "Small size X -pinch radiation source for application to phase-contrast x-ray radiography of biological specimens," in Nuclear Science Symposium Conference Record, 2002

  18. [18]

    X Pinch X-Ray Radiation above 8 keV for Application to High-Resolution Radiography of Biological Specimens,

    Byung Moo Song, T. A. Shelkovenko, S. A. Pikuz, M. A. Mitchell, K. M. Chandler, and D. A. Hammer, "X Pinch X-Ray Radiation above 8 keV for Application to High-Resolution Radiography of Biological Specimens," IEEE Transaction on Nuclear Science, 51(5),, vol. 51, no. 5, p. 1979, Oct. 2004

  19. [19]

    Use of X -pinches to diagnose behavior of low density CH foams in wire array z-pinches,

    S.C.Bott, D.J.Ampleford, S.N.Bland, J.P.Chittenden, S.V.Lebedev, J.B.A.Palmer, "Use of X -pinches to diagnose behavior of low density CH foams in wire array z-pinches," Rev. Sci. Instrum., vol. 75, no. 10, p. 3944, 2004. 13

  20. [20]

    Compact X-pinch based point x-ray source for phase contrast imaging of inertial confinement fusion capsules,

    F.N. Beg, R.B. Stephens, H.-W. Xu, D. Haas, S. Eddinger, G. Tynan, E. Shipton, B. DeBono, and K. Wagshal, "Compact X-pinch based point x-ray source for phase contrast imaging of inertial confinement fusion capsules," Appl. Phys. Let., vol. 89, p. 101502, 2006

  21. [21]

    X-Pinch Soft X-Ray Source for Microlithography,

    S.C. Glidden, D.A. Hammer, D.H. Kalantar, and N. Qi, "X-Pinch Soft X-Ray Source for Microlithography," in 9th International Conference on High-Power Particle Beams, 1992

  22. [22]

    The x-pinch as a point source of x rays for backlighting,

    D.H. Kalantar and D.A. Hammer, "The x-pinch as a point source of x rays for backlighting," Rev. Sci. Instrum., vol. 66, p. 779, 1995

  23. [23]

    The Center for the study of pulsed-power-driven high energy density plasmas: XP Pulser,

    "The Center for the study of pulsed-power-driven high energy density plasmas: XP Pulser," [Online]. Available: http://www.plasmacenter.cornell.edu/XPPulser.html

  24. [24]

    Optics and Plasma Physics Group, Pontificia Universidad Católica de Chile: Llampüdkeñ,

    "Optics and Plasma Physics Group, Pontificia Universidad Católica de Chile: Llampüdkeñ," [Online]. Available: http://www.fis.puc.cl/~plasma/

  25. [25]

    Llampüdkeñ: a high-current, low-impedance pulser employing an auxiliary exponential transmission line,

    H. Chuaqui, E. Wyndham, C. Friedli and M. Favre, "Llampüdkeñ: a high-current, low-impedance pulser employing an auxiliary exponential transmission line," Laser and Particle Beams, vol. 15, no. 2, pp. 241-248, 1997

  26. [26]

    A pulsed power gen erator for x-pinch experiments,

    X. Zou, R. Liu, N. Zeng, M. Han, J. Yuan, X. Wang, and G. Zhangx, "A pulsed power gen erator for x-pinch experiments," Laser and Particle Beams, vol. 24, p. 504, 2006

  27. [27]

    X-pinch experiments with pulsed power generator (PPG-1) at Tsinghua University,

    R. Liu, X. Zou, X. Wang, L. He and N. Zeng, "X-pinch experiments with pulsed power generator (PPG-1) at Tsinghua University," Laser and Particle Beams, vol. 26, no. 01, pp. 33-36, 2008

  28. [28]

    Voltage and current measurements on high power self‐magnetically insulated vacuum transmission lines,

    J. Maenchen, H.T. Sheldon, G.D. Rondeau, J.B. Greenly, and D.A. Hammer, "Voltage and current measurements on high power self‐magnetically insulated vacuum transmission lines," Rev. Sci. Instrum., vol. 55, no. 12, p. 1931, 1984

  29. [29]

    The Center for the study of pulsed-power-driven high energy density plasmas: Cobra,

    "The Center for the study of pulsed-power-driven high energy density plasmas: Cobra," [Online]. Available: http://www.plasmacenter.cornell.edu/cobra.html

  30. [30]

    Nevada Terawatt Facility: Zebra,

    "Nevada Terawatt Facility: Zebra," [Online]. Available: http://www.unr.edu/ntf/facility/zebra

  31. [31]

    X-ray spectroscopy and imaging of stainless steel X-pinches with application to astrophysics,

    A.S. Safronova, V.L. Kantsyrev, A.A. Esaulov, N.D. Ouart, U.I. Safronova, I. Shrestha, and K.M. Williamson, "X-ray spectroscopy and imaging of stainless steel X-pinches with application to astrophysics," Eur. Phys. J. Special Topics, vol. 169, p. 155–158, 2009

  32. [32]

    MAGPIE (Mega Ampere Generator for Plasma Implosion Experiments),

    "MAGPIE (Mega Ampere Generator for Plasma Implosion Experiments)," [Online]. Available: http://dorland.pp.ph.ic.ac.uk/magpie/

  33. [33]

    A high impedance mega‐ampere generator for fiber z‐pinch experiments,

    H. Mitchell, J. M. Bayley, J. P. Chittenden, J. F. Worley, A. E. Dangor1, M. G. Haines, and P. Choi, "A high impedance mega‐ampere generator for fiber z‐pinch experiments," Rev. Sci. Instrum., vol. 67, p. 1533, 1996

  34. [34]

    Study of the Multiwire X‐Pinch as a Load for Mega‐Ampere‐Range Pulsed Power Generators,

    Yu. Kalinin, S. Anan’ev, Yu. Bakshaev, P. Blinov, V. Bryzgunov, A. Chernenko, S. Danko, E. Ka zakov, A. Kingsep, V. Korolev, V. Mizhiritsky, S. Pikuz, T. Shelkovenko, V. Smirnov, S. Tkachenko, and A. Zelenin, "Study of the Multiwire X‐Pinch as a Load for Mega‐Ampere‐Range Pulsed Power Generators," in DENSE Z‐ PINCHES: Proceedings of the 7th International ...

  35. [35]

    Table-top X-pinch for x-ray radiography,

    F. N. Beg, K. Krushelnick, P. Lichtsteiner, A. Meakins, A. Kennedy, N. Kajumba, G. Burt, and A. E. Dangor, "Table-top X-pinch for x-ray radiography," Appl. Phys. Lett., vol. 82, no. 25, p. 4602, 2003

  36. [36]

    Pulsed Power Drivers at UCSD: X-Pinch Pulser,

    "Pulsed Power Drivers at UCSD: X-Pinch Pulser," [Online]. Available: http://fbeg.ucsd.edu/machines.shtml

  37. [37]

    Aluminium x-pinch driven by a low inductance pulsed power generator: experimental observations of its dynamics,

    R. Saavedra, E. Wyndham, H. Chuaqui, M. Favre and R. Aliaga-Rossel, "Aluminium x-pinch driven by a low inductance pulsed power generator: experimental observations of its dynamics," Optics and Plasma Physics Lab., Physics Dept., P. Universidad Católica de Chile

  38. [38]

    The redesign installation of light II-A pulsed power generator and its potential application,

    Chuan Wang, Xingdong Jiang, Jianzhong Wang, Sumin Wei, Naigong Zeng, Tianjue Zhang, "The redesign installation of light II-A pulsed power generator and its potential application," in Proceedings of PAC09, Vancouver, Canada., 2009

  39. [39]

    Adaptation of the ISIS Induction -Cell Driver to a Low- Impedance X-Pinch Drive,

    R.V. Shapovalov , W. Beezhold, V.I. Dimitrov (dec), "Adaptation of the ISIS Induction -Cell Driver to a Low- Impedance X-Pinch Drive," in Proceedings of NA-PAC, Pasadena, CA , 2013

  40. [40]

    Capacitors for Pulsed Power Systems,

    N. A. Ratakhin and V. F. Fedushchak, "Capacitors for Pulsed Power Systems," in Beams 2002: 14'h International Conference on High-Power Particle Beams, 2002

  41. [41]

    Design optimization of linear transformer driver (LTD) stage cell capacitors,

    A.H. Bushnell, B. Song, J. Ends, R. Miller, D. Johnsod, J. Maenchen, "Design optimization of linear transformer driver (LTD) stage cell capacitors," in Power Modulator Symposium, High-Voltage Workshop. Conference Record of the Twenty-Sixth International, 23-26 May 2004

  42. [42]

    Fast Pulse Capacitors, General Atomics Electronic Systems, Inc., San Diego, CA. 14

  43. [43]

    Gas switch studies for Linear Transformer Drivers,

    J. R. Woodworth, K. Hahn, J. A. Alexander, G. J. Denison, J. J. Leckbee, S. Glover, P. E. Wakeland, J. R. Blickem, R. Starbird, M. J. Harden, H. D. Anderson, F. R. Gruner, D. Van DeValde, "Gas switch studies for Linear Transformer Drivers," in Pulsed Power Conference, 16th IEEE International, 2007

  44. [44]

    Low-inductance gas switches for linear transformer drivers,

    J. R. Woodworth, J. A. Alexander, F. R. Gruner, W. A. Stygar, M. J. Harden, J. R. Blickem, G. J. Dension, F. E. White, L. M. Lucero, H. D. Anderson, L. F. Bennett, S. F. Glover, D. Van DeValde, and M. G. Mazarakis, "Low-inductance gas switches for linear transformer drivers," Phys. Rev. ST Accel. Beams, vol. 12, p. 060401, 2009

  45. [45]

    Low inductance switching studies for Linear Transformer Drivers,

    Woodworth, J.R., Alexander, J.A., Stygar, W.A., Bennett, L.F., Anderson, H.D., Harden, M.J., Blickem, J.R., Gruner, F.R., White, R., "Low inductance switching studies for Linear Transformer Drivers," in Pulsed Power Conference, PPC '09. IEEE, 2009

  46. [46]

    High voltage switches, L-3 Applied Technology

  47. [47]

    Compact submicrosecond, high current generator for wire explosion experiments,

    L. E. Aranchuk, A. S. Chuvatin, and J. Larour, "Compact submicrosecond, high current generator for wire explosion experiments," Rev. Sci. Instrum., vol. 75, p. 69, 2004

  48. [48]

    Experimental Study of X -Pinch in a Submicrosecond Regime,

    Leonid E. Aranchuk, Jean Larour, and Alexandre S. Chuvatin, "Experimental Study of X -Pinch in a Submicrosecond Regime," IEEE Transaction on Plasma Science, vol. 33, no. 2, pp. 990-996, Apr. 2005

  49. [49]

    250 kA compact linear transformer driver for wire array z -pinch loads,

    S. C. Bott, D. M. Haas, R. E. Madden, U. Ueda, Y. Eshaq, G. Collins IV, K. Gunasekera, D. Mariscal, J. Peebles, and F. N. Beg, "250 kA compact linear transformer driver for wire array z -pinch loads," Phys. Rev. ST Accel. Beams, vol. 14, p. 050401, 2001

  50. [50]

    A compact pulse generator for radiographic source supply,

    N. A. Ratakhin, V. F. Fedushchak, A. A. Erfort, N. V. Zharova, N. A. Zhidkova, S. A. Chaikovskii, and V. I. Oreshkin, "A compact pulse generator for radiographic source supply," Russian Physics Journal, vol. 50, no. 2, p. 193, 2007

  51. [51]

    X-Pinch Source of Subnanosecond Soft X-ray Pulses Based on Small-Sized Low-Inductance Current Generator,

    G. A. Mesyats, T. A. Shelkovenko, G. V. Ivanenkov, A. V. Agafonov, S. Yu. Savinov, S. A. Pikuz, I. N. Tilikin, S. I. Tkachenko, S. A. Chaikovskii, N. A. Ratakhin, V. F. Fedushchak, V. I. Oreshk in, A. V. Fedyunin, A. G. Russkikh, N. A. Labetskaya, ..., "X-Pinch Source of Subnanosecond Soft X-ray Pulses Based on Small-Sized Low-Inductance Current Generator...

  52. [52]

    MAIZE: a 1 MA LTD ‐ Driven Z‐Pinch at The University of Michigan,

    R. M. Gilgenbach, M. R. Gomez, J. Zier, W. W. Tang, D. French, Y. Y. Lau, M. G. Mazarakis, M. E. Cuneo, M. D. Johnson, B. V. Oliver, T. A. Mehlhorn, A. A. Kim, and V. A. Sinebryukhov, "MAIZE: a 1 MA LTD ‐ Driven Z‐Pinch at The University of Michigan," in AIP Conf. Proc, Alexandria, Virginia (USA), 2009

  53. [53]

    High current, 0.5 -MA, fast, 100-ns, linear transformer driver experiments,

    M.G. Mazarakis, W.E. Fowler, A.A. Kim, V.A. Sinebryukhov, S.T. Rogowski, R.A. Sharpe, D.H. McDaniel, C.L. Olson, J.L. Porter, K.W. Struve, W.A. Stygar, and J.R. Woodworth, "High current, 0.5 -MA, fast, 100-ns, linear transformer driver experiments," Phys. Rev. ST Accel. Beams, vol. 12, p. 050401, 2009

  54. [54]

    Development and tests of fast 1 -MA linear transformer driver stages,

    A.A.Kim, M.G. Mazarakis, V. Sinebryukhov, B. Kovalchuk, V.A. Visir, S.N. Volkov, F. Bayol, A.N. Bastrikov, V.G. Durakov, S.V. Frolov, V.M. Alexeenko, D.H. McDaniel, W.E. Fowler, K. LeChien, C. Olson, W.A. Stygar, K.W. Struve, J. Porter, and R. Gilgenbach, "Development and tests of fast 1 -MA linear transformer driver stages," Phys. Rev. ST Accel. Beams , ...

  55. [55]

    High-Current Linear Transformer Driver Development at Sandia National Laboratories,

    M. Mazarakis, W. Fowler, K. LeChien, F. Long, M. Matzen, D. McDaniel, R. McKee, C. Olson, J. Porter, S. Rogowski, K. Struve, W. Stygar, J. Woodworth, A. Kim, V. Sinebryukhov, R. Gilgenbach, M. Gomez, D.French, Y.Lau, J.Zier, D.VanDevalde, R.Sharpe, K.Ward, "High-Current Linear Transformer Driver Development at Sandia National Laboratories," IEEE Transacti...

  56. [56]

    Compact 810 kA linear transformer driver cavity,

    J. R. Woodworth, W. E. Fowler, B. S. Stoltzfus, W. A. Stygar, M. E. Sceiford, and M. G. Mazara kis, H. D. Anderson and M. J. Harden, J. R. Blickem, R. White, A. A. Kim, "Compact 810 kA linear transformer driver cavity," Phys. Rev. ST Accel. Beams, vol. 14, p. 040401, 2011

  57. [57]

    Temporal parameters of the X-pinch x-ray source,

    D. B. Sinars, S. A. Pikuz, T. A. Shelkovenko, K. M. Chandler, and D. A. Hammer, "Temporal parameters of the X-pinch x-ray source," Rev. Sci. Instrum., vol. 72, p. 2948, 2001

  58. [58]

    High Energy Density Z-Pinch Plasma Conditions with Picosecond Time Resolution,

    S. A. Pikuz, D. B. Sinars, T. A. Shelkovenko, K. M. Chandler, D. A. Hammer, G. V. Ivanenkov, W. Stepniewski, and I. Yu. Skobelev, "High Energy Density Z-Pinch Plasma Conditions with Picosecond Time Resolution," Phys. Rev. Let., vol. 3, no. 89, p. 035003, 2002

  59. [59]

    Time-resolved spectroscopy of Al, Ti, and Mo X pinch radiation using an X-ray streak camera,

    D.B. Sinars, S.A. Pikuz, T.A. Shelkovenko, K.M. Chandler, D.A. Hammer, J.P. Apruzese, "Time-resolved spectroscopy of Al, Ti, and Mo X pinch radiation using an X-ray streak camera," Journal of Quantitative Spectroscopy & Radiative Transfer, no. 78, pp. 61-83, 2003

  60. [60]

    Temporal Characteristics of X-ray Emission from X-Pinches,

    S. A. Pikuza, T. A. Shelkovenkoa, D. B. Sinarsa, and D. A. Hammer, "Temporal Characteristics of X-ray Emission from X-Pinches," Plasma Physics Reports, vol. 32, no. 12, p. 1020–1033, 2006. 15

  61. [61]

    Absolute Spectral Radiation Measurements from 200 -ns 200-kA X- Pinch in 10-eV–10-keV Range With 1-ns Resolution,

    Leonid E. Aranchuk and Jean Larour, "Absolute Spectral Radiation Measurements from 200 -ns 200-kA X- Pinch in 10-eV–10-keV Range With 1-ns Resolution," IEEE Transaction on Plasma Science, vol. 37, no. 4, p. 575, Apr. 2009

  62. [62]

    Effect of wire number on x-pinch discharges,

    J. S. Green, S. N. Bland, M. Collett, A. E. Dangor, K. Krushelnick, F. N. Beg, and I. Ross, "Effect of wire number on x-pinch discharges," Appl. Phys. Lett. , vol. 66, p. 261501, 2006

  63. [63]

    Multiwire X-Pinches at 1-MA Current on the COBRA Pulsed-Power Generator,

    T. A. Shelkovenko, S. A. Pikuz, J. D. Douglass, R. D. McBride, J. B. Greenly, and D. A. Hammer, "Multiwire X-Pinches at 1-MA Current on the COBRA Pulsed-Power Generator," IEEE Transaction on Plasma Science, vol. 34, no. 5, p. 2336, 2006

  64. [64]

    A Compact, High-Voltage E-Beam Pulser,

    M. G. Mazarakis and R. B. Spielman, "A Compact, High-Voltage E-Beam Pulser," in Proceeding of the 12th IEEE International Pulsed Power Conference, Monterey, CA, 1999

  65. [65]

    High current fast 100-ns LTD driver development in Sandia Laboratory,

    M. G. Mazarakis, W. E. Fowler, F. W. Long, D. H. McDaniel, C. L. Olson, S. T. Rogowski, R. A. Sharpe, K. W. Struve, and A. A. Kim, "High current fast 100-ns LTD driver development in Sandia Laboratory," in Proceeding of the 15th IEEE International Pulsed Power Conference, Monterey, CA, 2005

  66. [66]

    Shapovalov, Design of a Compact, Portable Plasma-Radiation-Source Generator at the Idaho Accelerator Center, CAM 2013 conference, Waterloo, Canada, Aug, 2013

    R. Shapovalov, Design of a Compact, Portable Plasma-Radiation-Source Generator at the Idaho Accelerator Center, CAM 2013 conference, Waterloo, Canada, Aug, 2013

  67. [67]

    Shapovalov, Design and Fabrication of Compact, Portable X-Pinch Driver based on 2 LTD bricks at the Idaho Accelerator Center, NWAPS meeting, Seattle, 2014

    R. Shapovalov, Design and Fabrication of Compact, Portable X-Pinch Driver based on 2 LTD bricks at the Idaho Accelerator Center, NWAPS meeting, Seattle, 2014

  68. [68]

    LTspice IV Getting Started Guide, 2011 Linear Technology

  69. [69]

    User, Assembly, and Maintenance Manual, May 6, 2011 Ktech corp

    LTD Generator. User, Assembly, and Maintenance Manual, May 6, 2011 Ktech corp

  70. [70]

    http://www.solidworks.com/,

    "http://www.solidworks.com/," SOLIDWORKS CORP.. [Online]

  71. [71]

    Spielman, Notes on design of RG-223-based non-integrated Rogowski coil

    R. Spielman, Notes on design of RG-223-based non-integrated Rogowski coil

  72. [72]

    Rogowski coil for measuring fast, high-level pulsed current,

    D. G. Pellinen, M. S. Di Capua, S. E. Sampayan, H. Gerbracht, and M. Wang, "Rogowski coil for measuring fast, high-level pulsed current," Rev. Sci. Instrum., vol. 51, no. 11, p. 1535, 1980