Pith. sign in

REVIEW 1 cited by

Comparative analysis of imaging configurations and objectives for Fourier microscopy

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1507.04037 v2 pith:LCLVSEZJ submitted 2015-07-14 physics.optics

classification physics.optics
keywords fourieranalysisimagingmicroscopyobjectivesaberrationsbeenconfigurations
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Fourier microscopy is becoming an increasingly important tool for the analysis of optical nanostructures and quantum emitters. However, achieving quantitative Fourier space measurements requires a thorough understanding of the impact of aberrations introduced by optical microscopes, which have been optimized for conventional real-space imaging. Here, we present a detailed framework for analyzing the performance of microscope objectives for several common Fourier imaging configurations. To this end, we model objectives from Nikon, Olympus, and Zeiss using parameters that were inferred from patent literature and confirmed, where possible, by physical disassembly. We then examine the aberrations most relevant to Fourier microscopy, including the alignment tolerances of apodization factors for different objective classes, the effect of magnification on the modulation transfer function, and vignetting-induced reductions of the effective numerical aperture for wide-field measurements. Based on this analysis, we identify an optimal objective class and imaging configuration for Fourier microscopy. In addition, as a resource for future studies, the Zemax files for the objectives and setups used in this analysis have been made publicly available.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Optical Levitation of Arrays of Microspheres

    physics.optics 2024-12 accept novelty 6.0 of 10

    A 25-element defect-free array of levitated microspheres in vacuum is demonstrated using time-shared optical traps, with sub-nanometer per root hertz camera-based displacement sensitivity.

Pith tools