Pith. sign in

REVIEW 1 cited by

Testbeam analysis of biasing structures for irradiated hybrid pixel detectors

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.03124 v2 pith:LS6TZSO4 submitted 2024-03-05 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords pixelsensorsatlasbiasdetectordevicesduringhybrid
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

Following the Phase-II upgrade during Long Shutdown (LS3), the LHC aims to reach a peak instantaneous luminosity of $7.5\times 10^{34}$cm$^{-2}$s$^{-1}$, which corresponds to an average of around 200 inelastic proton-proton collisions per beam-crossing (every 25 ns). To cope with these conditions, the ATLAS Inner Detector will be replaced by a new all-silicon system -- the Inner Tracker (ITk). The ITk will be operational for more than ten years, during which time ATLAS is expected to record approximately 4000 fb$^{-1}$ of data. The ITk's pixel sub-system is based on hybrid pixel modules with new silicon sensors and readout chips. These studies focus on testbeam campaigns undertaken to study the spatial resolution and efficiencies of hybrid pixel detector modules based on the first large-structure prototype front-end readout chip -- the RD53A -- using planar silicon sensors. These devices have been irradiated to replicate the effect of the high radiation environment present during operation in the ATLAS detector. Results for devices using sensors with different punch-through bias structures and using different readout chips are summarised. Those with sensors incorporating a punch-through bias structure are found to exhibit systematically lower efficiency than those without, as a result of local areas of relative inefficiency around the punch-through dots. Despite this, all devices measured are found to satisfy the requirement of 97% efficiency at $V_\mathrm{bias}=400$ V after being irradiated to end-of-life fluence.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. On the $L^q$ dimension of stationary measures for M\"{o}bius iterated function systems

    math.DS 2025-01 conditional novelty 7.0 of 10

    For Möbius iterated function systems satisfying the strongly Diophantine condition, the Lq spectrum of the stationary measure either equals the expected value for all q, or it becomes a linear function with slope belo...

Pith tools