Pith. sign in

REVIEW

MR sequence design to account for non-ideal gradient performance

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.17575 v4 pith:M5DVJBJR submitted 2024-03-26 physics.med-ph

classification physics.med-ph
keywords gradientsystemwaveformsperformancedesignhardwaremethodmodel
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are compensated by pre-emphasizing demanded waveforms. This process typically happens invisibly to the pulse sequence designer, allowing them to assume achieved gradient waveforms will be as desired. Whilst convenient, this requires system specifications exposed to the end-user to be substantially down-rated, since pre-emphasis adds an extra overhead to the waveforms. This strategy is undesirable for lower performance or resource-limited hardware. Instead, we propose an optimization-based method to design pre-compensated gradient waveforms that: (i) explicitly respect hardware constraints and (ii) improve imaging performance by correcting k-space samples directly. Gradient waveforms are numerically optimized by including a model for system imperfections. This is investigated in simulation using an exponential eddy current model, then experimentally using an empirical gradient system transfer function on a 7T MRI system. Our proposed method discovers solutions that produce negligible reconstruction errors while satisfying gradient system limits, even when classic pre-emphasis produces infeasible results. Substantial reduction in ghosting artefacts from EPI imaging was observed, including an average reduction of 77% in ghost amplitude in phantoms. This work demonstrates numerical optimization of gradient waveforms, yielding substantially improved image quality when given a model for system imperfections. While the method as implemented has limited flexibility, it could enable more efficient hardware usage, and may prove particularly important for maximizing performance of lower-cost systems.

Discussion (0). Sign in to comment.

Pith tools