Pith

open record

sign in

arxiv: 2601.13577 · v1 · pith:MZKWGFLP · submitted 2026-01-20 · physics.med-ph · physics.acc-ph

Toward Ultra-fast Treatments: Large Energy Acceptance Beam Delivery Systems and Opportunities for Proton Beam Therapy

Reviewed by Pith T0 review T1 audit T2 compute T3 formal T4 kernel pith:MZKWGFLPrecord.jsonopen to challenge →

classification physics.med-ph physics.acc-ph
keywords deliverybeamenergypotentialtreatmentultra-fastacceptanceelst
0
0 comments X
read the original abstract

Treatment delivery is largely determined by capabilities of the beam delivery system (BDS), where faster delivery can have many potential benefits including improved dosimetric quality, utility, cost effectiveness, patient throughput and comfort. Despite significant developments in accelerators, delivery methodologies, dose optimisation and more, the energy layer switching time (ELST) is still a persisting limitation in existing BDS. The ELST can contribute significantly to beam delivery time (BDT) and extend treatment times, requiring compensation by optimisation planning approaches, motion mitigation strategies, or active beam modification. This fundamental constraint can be addressed by increasing the narrow energy acceptance range of conventional beamlines to minimise the ELST, enabling ultra-fast delivery. A large energy acceptance (LEA) BDS has the potential to revolutionise PBT through immediate improvements to current treatment delivery and emerging delivery modalities: the complete exploitation of PBT - and unlocking its full potential - can only be made possible with advances in beam delivery technologies. We review the abundant opportunities offered by an ultra-fast BDS: shorter treatment times, reduced motion induced dose degradation, improved effectiveness of motion management techniques, possibilities for volumetric rescanning, bidirectional delivery, further planning optimisation, and novel delivery strategies. We overview the design concepts of several LEA proposals, technology requirements, and also discuss the remaining challenges and considerations with realising a LEA BDS in practice. There are multiple avenues requiring further development and study, however the clinical potential and benefits of this enabling technology are clear: ultra-fast delivery offers both immediate and future improvements to PBT treatments.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Physics-driven innovations toward the democratization of proton therapy

    physics.med-ph 2026-04 unverdicted novelty 3.0

    Compact proton therapy architectures with ~10-second field delivery times address both respiratory motion and economic viability, supporting broader clinical adoption.