REVIEW 4 major objections 5 minor 21 references
Comment on 'Anomalies in the Electronic Stopping of Slow Antiprotons in LiF', arXiv:2501.14381
T0 review · 4 major / 5 minor · reviewed 2026-08-16 · deepseek-v4-flash
Pith's one-line read This comment argues that the anomalies reported in the stopping of slow antiprotons in LiF are artifacts: the disputed curve misses measured data by up to a factor of 3, and the incommensurate-trajectory method can carry a 43% mean error.
desk verdict This comment makes a plausible case that PRL134's low-velocity antiproton stopping curve is too low, but its strongest quantitative claim leans on an unpublished data rescaling and an uncertain inference about trajectory sampling. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing mechanism is the Adiabatic Ionization Model (AIM): the stopping power $S_e(v) = \pi P_{\mathrm{cont}}\Delta E_{\mathrm{trans}} b_c(v)^2$, where $b_c(v)$ is the largest impact parameter at which half the collisional energy broadening $\Gamma(v)/2$ crosses the antiproton-lowered adiabatic excitation gap of LiF. The gap curve comes from self-consistent cluster calculations showing that the F-2p orbital is promoted until the gap vanishes near $R \approx 2$ a.u. The same $b_c=2$ a.u. cutoff is then used as a simplified collision statistic in histograms for incommensurate trajectories, which is what produces the 43% versus 12% mean-error contrast between two trajectory directions.
What would settle it
Rerun the criticized calculation with a large set of random incommensurate starts (say 100) and the same pseudopotential: if the anomalous low-velocity knee persists in the averaged stopping, the sampling-artifact explanation is wrong. Conversely, rerunning with the pseudopotential singularity removed should change the stopping by roughly 20% at high velocities if the pseudopotential critique is right.
Extended reading notes
Core claim
On the paper's own terms, the central claim is that the anomalies reported for slow antiprotons in LiF are not physical. The comment compares the criticized real-time TDDFT curve with corrected experimental data and finds deviations that reach a factor of 3 at low speeds, whereas the Adiabatic Ionization Model, built from self-consistent adiabatic excitation thresholds and collisional broadening, reproduces the data below about 0.5 a.u. It further argues that the incommensurate-trajectory method, if used with a single trajectory of about 48 Å, has large statistical fluctuations: with a fixed critical impact parameter $b_c=2$ a.u., the golden-ratio trajectory direction has a 43% mean error and can miss all close collisions (error $-100\%$), so the knee-like anomaly in the commented Letter may be a sampling artifact. The comment also targets the pseudopotential: a Coulomb pseudopotential that removes the singularity or suppresses the long-range dipole interaction can remove about 20% of the stopping at high velocities and far more at low velocities.
Load-bearing premise
The quantitative part of the critique assumes that the criticized paper used one (or very few) incommensurate trajectories and that the energy-loss statistics can be modeled by a fixed critical impact parameter of $b_c=2$ a.u.; if more trajectories were sampled, or if the real impact-parameter cutoff differs, the estimated 43% mean error and 100% worst-case error do not transfer.
Editorial extensions
If this is right
- The low-velocity knee reported for antiprotons in LiF should not be cited as evidence for anomalous stopping physics if it disappears once many trajectories are averaged.
- The Adiabatic Ionization Model, with a nearly constant energy loss below roughly $v=0.3$ a.u. down to the capture limit, becomes the working description of low-velocity antiproton stopping in LiF.
- Incommensurate-trajectory calculations of stopping in crystals should report convergence over at least ten independent trajectories to reach few-percent accuracy.
- The choice of trajectory direction matters: a golden-ratio incommensurate direction can substantially worsen the sampling error relative to a generic direction.
- Pseudopotential treatments of antiprotons need to be checked for removal of the Coulomb singularity and for suppression of the long-range dipole interaction, which materially change the stopping.
Reading between the lines
- I would infer that the same single-trajectory sampling critique applies to any incommensurate-trajectory stopping calculation with finite path length, not only to LiF, whenever the energy loss is dominated by rare close collisions.
- A decisive test would be to rerun the criticized calculation with 100 random starting points and the same pseudopotential: the comment's histogram model implies the stopping estimate should scatter by tens of percent, which would show up as a spread in the extracted slope.
- If the pseudopotential critique is correct, the reported anomaly should be sensitive to the potential's core treatment; varying the pseudopotential in a controlled way would separate sampling error from interaction error.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. This manuscript is a Comment on arXiv:2501.14381 / Phys. Rev. Lett. 134, 076401 (2025), which reported anomalies in the electronic stopping of slow antiprotons in LiF. The authors present calculations with their Adiabatic Ionization Model (AIM), compare them with CERN experimental data and with earlier rt-TDDFT results, and argue that the PRL134 results deviate from experiment by up to a factor of 3 at low velocities. They further argue that the PRL134 anomalies likely arise from the use of a single incommensurate trajectory (yielding large statistical errors) and from the use of a local Coulomb pseudopotential, and they criticize statements in PRL134 about antiproton capture, the Horsfield model, and resonance effects.
Significance. If the quantitative claims are correct, the comment would show that a published PRL contains serious artifacts and would support AIM as a better low-velocity description. The finite-length trajectory statistics presented in Figs. 4 and 5 are a useful illustration of potential sampling errors. However, the strongest numerical claim (factor of 3) depends on an unpublished data rescaling, and the trajectory-count inference is uncertain; therefore the overall significance depends on further documentation.
major comments (4)
- [Energy Loss Comparison for Antiprotons at low velocities, Fig. 3] The central claim that PRL134 deviates from experiment by up to a factor of 3 is based on multiplying the Møller et al. data by 1.13, and the sole justification is reference [14], described as "publication in preparation, 2025." This is not an available, checkable source; the 1.13 scaling factor, including its velocity dependence and uncertainty, must be documented in the present comment for the factor-of-3 statement to be fully supported.
- [On the importance and accuracy of incommensurate trajectories, Figs. 4 and 5] The quoted errors (43% mean for the golden-ratio direction, up to −100%/+47% for individual trajectories) are derived from a simplified AIM step-function model with b_c = 2 a.u. The authors acknowledge that "one cannot be sure" whether PRL134 used a single trajectory; if more than one trajectory was used, or if the real energy-loss statistics differ from this step function, these numbers do not transfer to PRL134. This section should be rewritten as an illustrative uncertainty analysis with explicit conditional language, not as a definitive error estimate for PRL134.
- [Collisional Broadening and Antiproton Energy Losses, Eq. (2)] The AIM curve in Fig. 3 depends on three estimated parameters: ΔE_trans = 14.5 eV, P_cont ≈ 58%, and b_c obtained from the crossing in Fig. 2. The paper does not give a sensitivity analysis for these choices, and the same b_c = 2 a.u. is later used for the statistical-error estimate, making part of the critique self-referential. The authors should state whether any AIM parameters are adjusted to reproduce the LiF antiproton data and should show the effect of varying them.
- [On the methodology of the PRL134 quantum calculations] The statements that the pseudopotential is "exactly ... responsible for the missing stopping-power contributions of 20% ... and partly for the 200%" and that the supercell "might not represent an undisturbed solid" are speculative hypotheses without supporting calculations. To be load-bearing, these points need to be either demonstrated with test calculations or explicitly labeled as conjectures that require further investigation.
minor comments (5)
- [After Fig. 3] The PRL134 curve is referred to as "dashed olive curve" and later as "green dashed curve," while the caption uses "green"; please make the color labels consistent.
- [Discussion of AIM agreement] Typo: "resonably" should be "reasonably".
- [Eq. (1)] The approximation `≈ E_gap − 1/(R^2 + r_mean^2)^0.5` would benefit from a note that it is a spherically-averaged estimate; as written, the equality of the matrix element with this closed form is not obvious.
- [References] Reference [14] is a "publication in preparation"; regardless of the major concern, the manuscript should provide a preprint or an appendix with the scaling details.
- [Abstract] The abstract claims "pointing to severe problems," while the body sometimes uses "might be"; the abstract could be more calibrated.
Circularity Check
The headline factor-of-3 disagreement with experiment is anchored in an unpublished 1.13 rescaling by the same authors, and the trajectory-error estimate imports the authors' own AIM threshold into the description of PRL134; the study otherwise compares to external benchmarks and is not severely circular.
-
self citation load bearing
[Section 'Energy Loss Comparison for Antiprotons at low velocities', Fig. 3 paragraph; Ref. [14]]
"We have scaled the displayed experimental data by Møller et al. [5] for ¯p by a factor of 1.13 to align their proton data with the most precise recent proton measurements (for further details see [14])."
The headline claim that PRL134 deviates from experiment by up to a factor of 3 is computed against these scaled data. The 1.13 factor is not derived or independently sourced in this paper; it is deferred to [14], which is the authors' own 'publication in preparation, 2025'. The claimed discrepancy therefore depends on an unpublished self-correction of the experimental benchmark, so a key quantitative conclusion is not independently checkable and is effectively assumed via self-citation.
-
other
[Section 'On the importance and accuracy of incommensurate trajectories', Figs. 4-5 paragraphs]
"Guided by the AIM, we assume a simplified low-energy promotion mechanism that leads to a fixed energy loss below a specific distance-of-closest-approach and otherwise zero energy loss (at larger impact parameters). ... defined by the critical impact parameter b_c = 2a.u."
The quantitative estimate that a single incommensurate trajectory 'may lead to an extremely large overall error' (43-100%) uses the authors' own Adiabatic Ionization Model as the source of the cross-section input b_c=2 a.u. The same model is then used as the reference curve in Fig. 3. The error estimate is therefore self-referential: it transfers a threshold from the authors' model onto PRL134's simulation rather than deriving PRL134's internal energy-loss statistics. This weakens the transfer, though it is not a by-construction identity.
full rationale
The comment is not a first-principles derivation; it is a comparative critique. Its strongest quantitative assertion (factor-of-3 disagreement with experiment) is anchored in a 1.13 rescaling of the CERN data deferred to an unpublished manuscript by the same authors, which is a load-bearing self-citation and is not independently verifiable. The trajectory-sampling error estimate also imports the AIM critical impact parameter into the description of PRL134's own calculation, making part of the critique model-dependent. However, the paper also makes direct external comparisons to PRL128 rt-TDDFT, CASP, and the raw Møller data, and the AIM parameters (P_cont, Delta E_trans, MCSCF threshold) are fixed from prior work and independent band-structure/density-of-states calculations rather than fitted to the antiproton LiF data. The central claim therefore retains independent content and does not reduce entirely to a fit or self-citation chain. Score 4 reflects one significant self-citation/calibration issue plus a self-referential error estimate, but no by-construction equivalence of the main conclusion to its inputs.
Assumptions & free parameters
free parameters (6)
- Experimental scaling factor =
1.13
- Denominator r_mean =
0.808 a.u.
- Mean ionization suppression factor Pcont =
~0.58
- Mean energy transfer Delta_E_trans =
14.5 eV
- Critical impact parameter b_c =
2 a.u. (model threshold)
- Trajectory length L =
~48 angstroms
assumptions (6)
- domain assumption The AIM step-function collisional-broadening scheme (Bohr's interaction-time prescription) is a valid approximation for low-velocity ion-solid excitation and energy loss.
- domain assumption PRL128 rt-TDDFT results are accurate to about 5% and can serve as an independent benchmark.
- ad hoc to paper The 1.13 scaling of the CERN experimental data is justified.
- ad hoc to paper The simplified collision model (fixed energy loss for encounters with b below b_c=2 a.u., zero otherwise) captures PRL134's energy-loss statistics.
- domain assumption A vanishing excitation gap at R below 2 a.u. (Fermi-Teller promotion) leads to ionization and finite energy loss.
- domain assumption No delocalized in-gap state exists in pristine LiF, so the Horsfield model is inapplicable.
Cite this review
Pith. "Pith review of Comment on 'Anomalies in the Electronic Stopping of Slow Antiprotons in LiF', arXiv:2501.14381." pith.science (2026). https://pith.science/paper/NPIC3ZK5
@misc{pith2026250421839,
author = {Pith},
title = {Pith review of: Comment on 'Anomalies in the Electronic Stopping of Slow Antiprotons in LiF', arXiv:2501.14381},
year = {2026},
howpublished = {\url{https://pith.science/paper/NPIC3ZK5}},
note = {Machine review of arXiv:2504.21839}
}
read the original abstract
This work contains detailed discussions on the contents of Phys. Rev. Lett. 134, 076401 (2025), in the following denoted PRL134. In this comment, we revisit and elaborate on the Adiabatic Ionization Model (AIM) for the energy loss of antiparticles in matter, with particular reference to its theoretical foundation as established previously. The AIM framework plays a central role in describing the ionization dynamics in the low-velocity regime considered by the authors of PRL134. Calculated AIM results for the energy loss of antiprotons in LiF crystals are compared to experimental data and different other models, pointing to severe problems of the PRL134 results. Beyond this specific comparative theoretical investigation, we critically examine several statements and assumptions made in PRL134. Certain claims presented therein appear to be inconsistent with established theoretical principles or are insufficiently justified by the data and arguments provided. As such, we believe that further clarification, and in some cases, a more rigorous justification, is necessary to substantiate those points.
Figures
Figures from the paper (2 more)
Reference graph
Works this paper leans on
- [14]
-
[1]
Anomalies in the electronic stopping of slow antiprotons in LiF
G. Massillon-JL, A. A. Correa, X. Andrade, and E. Artacho, “Anomalies in the electronic stopping of slow antiprotons in lif,” arXiv:2501.14381 andPhysical Review Letters, vol. 134/7, p. 076401, 2025
work page Pith review arXiv 2025
-
[2]
The capture of negative mesotrons in matter,
E. Fermi and E. Teller, “The capture of negative mesotrons in matter,”Physical Review, vol. 72/5, p. 399, 1947
work page 1947
-
[3]
Vanishing gap in lif for electronic excitations by slow antiprotons,
B. Solleder, L. Wirtz, and J. Burgd¨ orfer, “Vanishing gap in lif for electronic excitations by slow antiprotons,”Physical Review B, vol. 79, p. 125107, 2009
work page 2009
-
[4]
G. Schiwietz, U. Wille, R. D´ ıez Mui˜ no, P. D. Fainstein, and P. L. Grande, “Comprehensive analysis of the stopping power of antiprotons and negative muons in he and h2 gas targets,”Journal of Physics B: At. Mol. Opt. Phys., vol. 29, p. 307, 1996
work page 1996
-
[5]
Stopping Power in Insulators and Metals without Charge Exchange,
S.P. Møller, A. Csete, T. Ichioka, H. Knudsen, U.I. Uggerhøj, and H.H. Andersen, “Stopping Power in Insulators and Metals without Charge Exchange,”Physical Review Letters93/4, p. 042502, 2004
work page 2004
-
[6]
Ab initio prediction of a negative barkas coefficient for slow protons and antiprotons in lif,
X. Qi, F. Bruneval, and I. Maliyov, “Ab initio prediction of a negative barkas coefficient for slow protons and antiprotons in lif,”Physical Review Letters, vol. 128, p. 043401, 2022
work page 2022
-
[7]
S. Samarin, O. Artamonov, A. Suvorova, A. Sergeant, and J. Williams, “Measurements of insulator band parameters using a combination of single-electron and two-electron spectroscopy,”Solid State Communications, vol. 129, p. 389, 2004. see also references therein
work page 2004
Show all 21 references
-
[8]
Adiabatic orbitals of the ion-image-charge system in ion-metal-surface scattering,
U. Wille, “Adiabatic orbitals of the ion-image-charge system in ion-metal-surface scattering,”Z Phys D - Atoms, Molecules and Clusters 21 (Suppl 1), vol. 21, p. S353, 1991
1991
-
[9]
Shift of band gap from direct to indirect and optical response of lif under pressure,
A. Sajid, G. Murtaza, and A. Reshak, “Shift of band gap from direct to indirect and optical response of lif under pressure,” Modern Physics Letters B, vol. 27/9, p. 1350061, 2013
2013
-
[10]
Ab initio calculations of electronic and optical properties in o-doped lif crystal,
M. Guo, X. Zhang, H. Gu, and N. Wang, “Ab initio calculations of electronic and optical properties in o-doped lif crystal,” Central European Journal of Physics, vol. 6, p. 321, 2008
2008
-
[11]
Investigation of simultaneous inner- and outer-shell ionization and auger-electron emission in slow ar+ + ar collisions at intermediate impact parameters,
G. Schiwietz, B. Skogvall, J. Tanis, and D. Schneider, “Investigation of simultaneous inner- and outer-shell ionization and auger-electron emission in slow ar+ + ar collisions at intermediate impact parameters,”Physical Review A, vol. 38, p. 5552,
-
[12]
Classical electrodynamics,
J. D. Jackson, “Classical electrodynamics,” 1981
1981
-
[13]
Perturbed-stationary-state theory of atomic inner-shell ionization by heavy charged particles,
G. Basbas, W. Brandt, and R. H. Ritchie, “Perturbed-stationary-state theory of atomic inner-shell ionization by heavy charged particles,”Phys. Rev. A, vol. 7, pp. 1971–1976, Jun 1973
1971
-
[15]
http://www.casp-program.org
2025"http://www.casp-program.org". ¯pcalculations with the stopping-power program (version 6.0) by Grande and Schiwietz. See, e.g., Nucl. Instr. Meth. B267, 859 (2009) or NIM-B273, 1 (2012)
2009
-
[16]
Dynamical reconstruction of the exciton in lif with inelastic x-ray scattering,
P. Abbamonte, T. Graber, J. Reed, S. Smadici, C.-L. Yeh, A. Shukla, J.-P. Rueff, and W. Ku, “Dynamical reconstruction of the exciton in lif with inelastic x-ray scattering,”Proceedings of the National Academy of Sciences, vol. 105, no. 34, pp. 12159–12163, 2008
2008
-
[17]
Resonant coherent excitation of channeled ions,
S. Datz, C. D. Moak, O. H. Crawford, H. F. Krause, P. F. Dittner, J. G. del Campo, J. A. Biggerstaff, P. D. Miller, P. Hvelplund, and H. Knudsen, “Resonant coherent excitation of channeled ions,”Phys. Rev. Lett., vol. 40, pp. 843–847, Mar 1978
1978
-
[18]
Resonant coherent excitation of fast heavy ions in crystals,
C. Moak, J. Biggerstaff, O. Crawford, P. Dittner, S. Datz, J. Del Campo, P. Hvelplund, H. Knudsen, H. Krause, P. Miller, and S. Overbury, “Resonant coherent excitation of fast heavy ions in crystals,”Nuclear Instruments and Methods in Physics Research, vol. 194, no. 1, pp. 327...
1982
-
[19]
Electronic stopping power in lif from first principles,
J. M. Pruneda, D. S´ anchez-Portal, A. Arnau, J. I. Juaristi, and E. Artacho, “Electronic stopping power in lif from first principles,”Physical Review Letters, vol. 99/23, p. 235501, 2007
2007
-
[20]
Calculating electronic stopping power in materials from first principles,
A. A. Correa, “Calculating electronic stopping power in materials from first principles,”Computational Materials Science, vol. 150, pp. 291–303, 2018
2018
-
[1988]
see also references therein
Reviewed August 16, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.