REVIEW 4 major objections 6 minor 64 references
Rotating polarization magnetometry
T0 review · 4 major / 6 minor · reviewed 2026-08-10 · deepseek-v4-flash
Pith's one-line read Rotating-polarization pumping outperforms AMOR at 100 µT
desk verdict The RotPol-vs-AMOR comparison is a real experimental result, but the headline sensitivity numbers do not survive contact with Eq. (2). read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing element is the rotating-polarization pump: a Mach-Zehnder interferometer in which two orthogonally polarized beams are frequency-shifted by acousto-optic modulators driven at slightly different frequencies, so their superposition is a beam whose linear polarization precesses continuously at the difference frequency νm. When νm is set to the Larmor frequency, the rotating polarization resonantly drives a transverse atomic polarization that stays parallel to the light's polarization at all times, suppressing AOC. The same device, with a polarizer inserted after the recombining beam splitter, converts the output into amplitude-modulated light, enabling a like-for-like comparison of RotPol and AMOR under identical atomic conditions.
What would settle it
Reproduce the AMOR measurement using an amplitude-modulation scheme that does not produce the repumping relaxation described in Section III.B, e.g., by keeping light intensity constant while modulating only the degree of circular or elliptical polarization, or by adding a repump beam; if the high-field amplitude decline then differs from the RotPol decline, the paper's exculpation of AOC is invalidated.
Extended reading notes
Core claim
The central discovery is that by synchronizing the rotation of the pump beam's linear polarization with the Larmor precession of atomic spins in a coated 87Rb vapor cell, one can continuously replenish a dynamically precessing transverse atomic polarization without ever letting the light polarization and the atomic polarization point in different directions. This arrangement keeps the alignment-to-orientation conversion angle at zero while still delivering a modulated NMOR signal, and the measured signal amplitude is roughly 1.5–2 times larger and about 30% narrower than that obtained with amplitude-modulated light generated in the same setup. The comparative measurements show that the high-field amplitude reduction is nearly the same for both techniques (~40% over the explored range), which the authors take as evidence that AOC is not the main cause; they attribute the decline instead to nonlinear Zeeman splitting, decoupling of hyperfine interaction, and field inhomogeneities.
Load-bearing premise
The comparison between RotPol and AMOR assumes that the only meaningful difference between the two techniques is the presence of alignment-to-orientation conversion, even though AMOR also modulates light intensity and the paper shows that this introduces extra atomic relaxation in AMOR.
Editorial extensions
If this is right
- Rotating-polarization NMOR provides a practical route to sensitive magnetometry at fields up to at least 100 µT, covering a dynamic range about three times Earth's field, without active compensation.
- The comparison shows that the signal and sensitivity advantage over AMOR holds across a wide range of pump and probe powers, with RotPol always giving larger amplitudes.
- Since AOC is not the cause of high-field signal decline, efforts to improve high-field NMOR should focus on nonlinear Zeeman splitting, hyperfine decoupling, and magnetic-field inhomogeneity rather than on avoiding AOC.
- The authors point out that increasing the atomic density close to one optical depth could raise sensitivity by roughly an order of magnitude, and that a self-oscillating mode using feedback of the rotation signal could enable automatic field tracking.
Reading between the lines
- The comparison between RotPol and AMOR does not isolate AOC alone, because AMOR also involves sinusoidal intensity modulation that the paper itself shows introduces extra relaxation by repumping polarized atoms; if that extra relaxation rather than AOC is the dominant cause of AMOR's weaker signals, the conclusion about AOC would be unsupported.
- A natural next experiment would be to measure the high-field decline using a scheme that modulates polarization direction without any intensity variation in a regime where AOC should be significant, to separate the two effects directly.
- The rotating-polarization approach could be adapted to other alkali species and to chip-scale or fiber-integrated setups, and might combine with different operating regimes, though those extensions are not explored here.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript reports an experimental implementation of NMOR magnetometry using continuously rotating linear polarization (RotPol) in a 87Rb vapor cell, and compares it with amplitude-modulated NMOR (AMOR). The authors report that RotPol produces larger signal amplitudes, narrower resonances, and better magnetic-field sensitivity (650 fT/√Hz versus 1.15 pT/√Hz at a stated field of 100 µT). They also conclude, from the similar field dependence of RotPol and AMOR signals and the larger RotPol amplitudes, that the well-known high-field NMOR signal deterioration is not caused by alignment-to-orientation conversion (AOC).
Significance. If fully substantiated, the technique would be a useful alternative for high-field optical magnetometry, extending sensitive NMOR operation to fields of order 100 µT and beyond. The paper provides extensive parametric maps of signal amplitude, width, and sensitivity versus pump and probe powers, and it uses the same experimental hardware for the RotPol and AMOR comparisons, which is a genuine strength. However, the quantitative sensitivity claims rest on a dimensionally inconsistent formula and an unexplained disagreement between the stated and captioned operating fields, and the AOC conclusion is not uniquely determined by the RotPol/AMOR comparison as presented.
major comments (4)
- [Section III.D, Eq. (2)] Equation (2) is dimensionally inconsistent as written. If A is in volts, SNR is dimensionless, and γ is in hertz, then A/(SNR·γ) has units V·s, while gµB/ℏ has units rad/(T·s), so the right-hand side has units V/T rather than T. The correct conversion for a Lorentzian dispersion-type discriminator would instead be δB = (ℏ/(gµB))·(γ/SNR) (or h/(gµB)·(γ/SNR) for cyclic Larmor frequency). Since the reported optimal sensitivities of 650 fT/√Hz and 1.15 pT/√Hz and the entire map in Fig. 7 are derived from this relation, all quantitative sensitivity claims must be recomputed with the correct expression, and the SNR definition and noise bandwidth must be specified.
- [Section III.D and Fig. 7 caption] There is a direct factual disagreement about the operating field: the text and abstract state that the sensitivity measurements were performed at 100 µT, while the Fig. 7 caption says the measurements were made at "≈30 µT." This discrepancy changes the physical regime being characterized and prevents reproduction of the reported sensitivities. The authors need to state the actual field for each data set and, ideally, show how the sensitivity varies across the 30–100 µT range.
- [Fig. 7 and Section III.D] No noise calibration or error bars are provided for the sensitivity values. Since Eq. (2) depends directly on the signal-to-noise ratio, the reported sensitivity figures require a description of how the noise spectral density was measured (e.g., detector noise floor, photon shot noise, probe-power dependence, measurement bandwidth) and an uncertainty estimate for the fitted amplitude and width. Without this information, the claimed quantitative advantage of RotPol over AMOR (650 fT/√Hz versus 1.15 pT/√Hz) is not reproducible from the manuscript.
- [Section III.B, Fig. 5, and Section V] The conclusion that AOC is not responsible for the high-field NMOR signal reduction is not uniquely supported by the RotPol/AMOR comparison. The two pumping schemes differ not only in polarization rotation relative to the atomic polarization but also in intensity modulation: RotPol uses continuous intensity while AMOR uses sinusoidal amplitude modulation, and the paper itself attributes the larger AMOR width to additional repumping-induced relaxation in a sinusoidally modulated pump (Section III.B). This additional relaxation mechanism could account for the smaller AMOR amplitudes and the observed linewidth differences, so the comparison does not isolate AOC. The causal claim about AOC should be tempered, or a control should be added in which the polarization-rotation character is changed without changing the intensity-modulation character.
minor comments (6)
- [Section I] "surveys natural resources" should be "surveying natural resources".
- [Section III.C] "interestteresting" is a typo and should be "interesting".
- [Fig. 3 caption] "triple Lorenzian" should be "triple Lorentzian".
- [Fig. 7 color bar] The label "Sensitivity(pT/ Hz)" should use the conventional notation "pT/√Hz."
- [Section V and Section IV] The summary states that sensitivity can be increased by up to threefold, while the Discussion anticipates a ten-fold increase from concentration optimization; these two numbers should be reconciled.
- [References [57] and [58]] References [57] and [58] are incomplete: they list only the journal, volume, page, and year, without author and title information.
Circularity Check
No significant circularity: the paper's claims are experimental comparisons, not derivations from fitted inputs.
full rationale
The central claims are measured RotPol/AMOR signal amplitudes, widths, slopes, and sensitivities (Figs. 3-7, Table I), obtained by fitting a triple-Lorentzian profile to raw signals. Nothing in the fitting function (Eq. 1) encodes the comparative conclusion; the conclusion that RotPol outperforms AMOR and that AOC is not the main cause of high-field deterioration follows from comparing measured resonances, not from an input chosen to produce that result. The only self-citation, Ref. [49] for the rotating-polarization generator, is tooling: the apparatus is cited as a device, not as authority for the physics conclusion. The AMOR comparison does include a possible confound acknowledged by the authors themselves (sinusoidal modulation adds relaxation, Sec. III.B), but an alternative explanation is an experimental-design weakness, not circularity. The dimensional issue in Eq. (2) noted in the skeptic pass, if correct, is a correctness/reproducibility defect and does not make the comparison circular: the sensitivity values are still measured quantities reported from the fit parameters. No prediction is constructed to equal its own input, and no load-bearing step reduces to a self-citation or to a definition. The manuscript is self-contained as an experimental report, so the circularity score is 0.
Assumptions & free parameters
free parameters (3)
- Central resonance amplitude A =
1.947(26) V (RotPol, 10 µW pump)
- Resonance width γ =
27.17(81) Hz (RotPol, 10 µW pump)
- Satellite amplitude A1 and width γ1 =
Not reported separately in the paper
assumptions (4)
- domain assumption The rotating-polarization generator (Ref [49]) produces light whose linear polarization rotates continuously at frequency νm without parasitic intensity modulation.
- domain assumption The triple-Lorentzian model Eq (1) adequately describes the NMOR resonance line shapes.
- ad hoc to paper The sensitivity formula Eq (2) correctly relates amplitude, width, and SNR to magnetic sensitivity.
- domain assumption The only relevant difference between RotPol and AMOR for the AOC test is the absence or presence of AOC, with other differences (for example, pump-induced relaxation) not affecting the field-dependence trend.
Cite this review
Pith. "Pith review of Rotating polarization magnetometry." pith.science (2026). https://pith.science/paper/P5HQTUKE
@misc{pith2026241220044,
author = {Pith},
title = {Pith review of: Rotating polarization magnetometry},
year = {2026},
howpublished = {\url{https://pith.science/paper/P5HQTUKE}},
note = {Machine review of arXiv:2412.20044}
}
read the original abstract
Precise magnetometry is vital in numerous scientific and technological applications. At the forefront of sensitivity, optical atomic magnetometry, particularly techniques utilizing nonlinear magneto-optical rotation (NMOR), enables ultraprecise measurements across a broad field range. Despite their potential, these techniques reportedly lose sensitivity at higher magnetic fields, which is attributed to the alignment-to-orientation conversion (AOC) process. In our study, we utilize light with continuously rotating linear polarization to avoid AOC, producing robust optical signals and achieving high magnetometric sensitivity over a dynamic range nearly three times greater than Earth's magnetic field. We demonstrate that employing rotating polarization surpasses other NMOR techniques that use modulated light. Our findings also indicate that the previously observed signal deterioration is not due to AOC, suggesting an alternative cause for this decline.
Figures
Figures from the paper (3 more)
Reference graph
Works this paper leans on
-
[49]
P. W lodarczyk, S. Pustelny, and D. Bud- ker, Rev. Sci. Instrum. 90, 013110 (2019), https://pubs.aip.org/aip/rsi/article- pdf/doi/10.1063/1.5066071/14756140/013110 1 online.pdf
-
[1]
Budker and M
D. Budker and M. Romalis, Nat. Phys. 3, 227 (2007)
2007
-
[2]
D. Budker and D. F. Jackson Kimball, Optical Magne- tometry (Cambridge University Press, 2013)
work page 2013
-
[4]
J. C. Allred, R. N. Lyman, T. W. Kornack, and M. V. Romalis, Phys. Rev. Lett. 89, 130801 (2002)
work page 2002
-
[5]
E. B. Alexandrov, Phys. Scr. 2003, 27 (2003)
work page 2003
-
[6]
S. J. Seltzer, P. J. Meares, and M. V. Romalis, Phys. Rev. A 75, 051407 (2007)
work page 2007
-
[7]
S. Groeger, G. Bison, J.-L. Schenker, R. Wynands, and W. A., Eur. Phys. J. D A 38, 239 (2006)
work page 2006
-
[8]
S. Pustelny, A. Wojciechowski, M. Gring, M. Kotyrba, J. Zachorowski, and W. Gawlik, J Appl. Phys. 103, 063108 (2008), https://pubs.aip.org/aip/jap/article- pdf/doi/10.1063/1.2844494/13946272/063108 1 online.pdf
Show all 64 references
-
[9]
Y. J. Kim and I. Savukov, Sci. Rep. 6, 24773 (2016)
2016
-
[10]
A. P. Colombo, T. R. Carter, A. Borna, Y.-Y. Jau, C. N. Johnson, A. L. Dagel, and P. D. D. Schwindt, Opt. Ex- press 24, 15403 (2016)
2016
-
[11]
Oelsner, V
G. Oelsner, V. Schultze, R. IJsselsteijn, and R. Stolz, EPJ Quantum Technol. 6, 1 (2019)
2019
-
[12]
Bevington, R
P. Bevington, R. Gartman, and W. Chalupczak, Rev. Sci. Instrum. 90, 013103 (2019)
2019
-
[13]
J. Wang, W. Fan, K. Yin, Y. Yan, B. Zhou, and X. Song, Phys. Rev. A 101, 053427 (2020)
2020
-
[14]
X. Fang, K. Wei, T. Zhao, Y. Zhai, D. Ma, B. Xing, Y. Liu, and Z. Xiao, Opt. Express 28, 26447 (2020)
2020
-
[15]
Bison, R
G. Bison, R. Wynands, and A. Weis, Appl. Phys. B 76, 325 (2003)
2003
-
[16]
Murzin, D
D. Murzin, D. J. Mapps, K. Levada, V. Belyaev, A. Omelyanchik, L. Panina, and V. Rodionova, Sensors 20, 10.3390/s20061569 (2020)
2020 doi
-
[17]
M. J. Brookes, J. Leggett, M. Rea, R. M. Hill, N. Holmes, E. Boto, and R. Bowtell, Trends Neurosci.45, 621 (2022)
2022
-
[18]
Y. Lu, T. Zhao, W. Zhu, L. Liu, X. Zhuang, G. Fang, and X. Zhang, Sensors 23, 5318 (2023)
2023
-
[19]
A. M. Akulshin, D. Budker, F. Pedreros Bustos, T. Dang, E. Klinger, S. M. Rochester, A. Wickenbrock, and R. Zhang, Phys. Rep. 1106, 1 (2025)
2025
-
[20]
Bevilacqua, V
G. Bevilacqua, V. Biancalana, A. B. A. Baranga, Y. Dancheva, and C. Rossi, J Magn. Reson. 263, 10.1016/j.jmr.2015.12.018 (2016)
2016 doi
-
[21]
Tayler, T
M. Tayler, T. Theis, T. Sjolander, J. Blanchard, A. Kent- 8 ner, S. Pustelny, A. Pines, and D. Budker, Rev. Sci. In- strum. 88, 10.1063/1.5003347 (2017)
2017 doi
-
[22]
J. A. Barskiy, J. W. Blanchard, D. Budker, J. Eills, S. Pustelny, K. F. Sheberstov, M. C. D. Tayler, and A. H. Trabesinger, Prog. Nucl. Magn. Reson. Spectrosc. (2025), accepted for publication, arXiv:2409.09048
2025 arXiv
-
[23]
Pustelny, D
S. Pustelny, D. Kimball, C. Pankow, M. Ledbetter, P. Wlodarczyk, P. Wcislo, M. Pospelov, J. Smith, J. Read, W. Gawlik, and D. Budker, Ann. Phys. 525, 10.1002/andp.201300061 (2013)
2013 doi
-
[24]
Jiang, H
M. Jiang, H. Su, A. Garcon, X. Peng, and D. Budker, Nat. Phys. 17, 10.1038/s41567-021-01392-z (2021)
2021 doi
-
[25]
W. A. Terrano and M. V. Romalis, Quantum Sci. Tech- nol. 7, 014001 (2021)
2021
-
[26]
Afach, D
S. Afach, D. A. Tumturk, H. Bekker, B. C. Buchler, D. Budker, K. Cervantes, A. Derevianko, J. Eby, N. L. Figueroa, R. Folman, D. Gavil´ an-Mart ´ ın, M. Givon, Z. D. Gruji´ c, H. Guo, P. Hamilton, M. P. Hedges, D. F. J. Kimball, S. Khamis, D. Kim, E. Klinger, A. Krye- madhi, X...
2024
-
[27]
I. M. Bloch and S. Kalia, J. High Energ. Phys. 2024, 178
2024
-
[28]
S. J. Seltzer and M. V. Romalis, Appl. Phys. Lett. 85, 4804 (2004), https://pubs.aip.org/aip/apl/article- pdf/85/20/4804/18600614/4804 1 online.pdf
2004
-
[29]
Belfi, G
J. Belfi, G. Bevilacqua, V. Biancalana, S. Cartaleva, Y. Dancheva, and L. Moi, Journal of the Optical Soci- ety of America B 24, 2357 (2007)
2007
-
[30]
Z. Y. Chu, X. G. Sun, S. A. Wan, and J. C. Fang, Opt. Precis. Eng. 22, 10.3788/OPE.20142207.1808 (2014)
2014
-
[31]
Papoyan, S
A. Papoyan, S. Shmavonyan, A. Khanbekyan, K. Khan- bekyan, C. Marinelli, and E. Mariotti, Appl. Opt. 55, 892 (2016)
2016
-
[32]
M. E. Limes, E. L. Foley, T. W. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V. G. Lucivero, and M. V. Romalis, Phys. Rev. Appl. 14, 10.1103/PhysRe- vApplied.14.011002 (2020)
2020 doi
-
[33]
Wilson, C
N. Wilson, C. Perrella, R. Anderson, A. Luiten, and P. Light, Phys. Rev. Res. 2, 10.1103/PhysRevRe- search.2.013213 (2020)
2020 doi
-
[34]
V. G. Lucivero, W. Lee, T. W. Kornack, M. E. Limes, E. L. Foley, and M. V. Romalis, Phys. Rev. Appl. 18, 10.1103/PhysRevApplied.18.L021001 (2022)
2022 doi
-
[35]
Zhang, y
L. Zhang, y. Yang, N. Zhao, J. He, and J. Wang, Sensors 22, 10.3390/s22197598 (2022)
2022 doi
-
[36]
Hunter, M
D. Hunter, M. S. Mrozowski, A. McWilliam, S. J. Ingleby, T. E. Dyer, P. F. Griffin, and E. Riis, J. Opt. Soc. Am. B 40, 2664 (2023)
2023
-
[37]
Alexandrov, M
E. Alexandrov, M. Balabas, A. Pasgalev, A. Vershovskii, and N. Yakobson, Laser Phys. 6 (1996)
1996
-
[38]
Scholtes, S
T. Scholtes, S. Pustelny, S. Fritzsche, V. Schultze, R. Stolz, and H. G. Meyer, Phys. Rev. A 94, 10.1103/PhysRevA.94.013403 (2016)
2016 doi
-
[39]
Ledbetter, V
M. Ledbetter, V. Acosta, S. Rochester, D. Budker, S. Pustelny, and V. Yashchuk, Phys. Rev. A 75, 10.1103/PhysRevA.75.023405 (2007)
2007 doi
-
[40]
P. Put, P. Wcis lo, W. Gawlik, and S. Pustelny, Phys. Rev. A 100, 10.1103/PhysRevA.100.043838 (2019)
2019 doi
-
[41]
P. Put, K. Popio lek, and S. Pustelny, Scientific Reports 9, 10.1038/s41598-019-39282-3 (2019)
2019 doi
-
[42]
W. E. Bell and A. L. Bloom, Phys. Rev. Lett. 6, 10.1103/PhysRevLett.6.280 (1961)
1961 doi
-
[43]
Budker, D
D. Budker, D. F. Kimball, V. V. Yashchuk, and M. Zolo- torev, Phys. Rev. A 65, 055403 (2002)
2002
-
[44]
Acosta, M
V. Acosta, M. P. Ledbetter, S. M. Rochester, D. Bud- ker, D. F. Jackson Kimball, D. C. Hovde, W. Gawlik, S. Pustelny, J. Zachorowski, and V. V. Yashchuk, Phys. Rev. A 73, 053404 (2006)
2006
-
[45]
Gawlik, L
W. Gawlik, L. Krzemie´ n, S. Pustelny, D. Sangla, J. Zachorowski, M. Graf, A. O. Sushkov, and D. Budker, Appl. Phys. Lett. 88, 131108 (2006), https://pubs.aip.org/aip/apl/article- pdf/doi/10.1063/1.2190457/14009075/131108 1 online.pdf
2006 doi
-
[46]
V. M. Acosta, M. Auzinsh, W. Gawlik, P. Grisins, J. M. Higbie, D. F. J. Kimball, L. Krzemien, M. P. Led- better, S. Pustelny, S. M. Rochester, V. V. Yashchuk, and D. Budker, Optics Express 16, 10.1364/oe.16.011423 (2008)
2008 doi
-
[48]
Budker, D
D. Budker, D. F. Kimball, S. M. Rochester, and V. V. Yashchuk, Phys. Rev. Lett. 85, 2088 (2000)
2000
-
[50]
Pustelny, V
S. Pustelny, V. Schultze, T. Scholtes, and D. Budker, Rev. Sci. Instrum. 87, 10.1063/1.4952962 (2016)
2016 doi
-
[51]
D. A. Steck, Rubidium 87 d line data, http://steck.us/ alkalidata (2010), revision 2.1.4, 23 December 2010
2010
-
[52]
Pustelny, D
S. Pustelny, D. J. Kimball, S. Rochester, V. Yashchuk, and D. Budker, Phys. Rev. A 74, 10.1103/Phys- RevA.74.063406 (2006)
2006 doi
-
[53]
Pustelny, D
S. Pustelny, D. F. Jackson Kimball, S. M. Rochester, V. V. Yashchuk, W. Gawlik, and D. Budker, Phys. Rev. A 73, 023817 (2006)
2006
-
[54]
Drampyan, S
R. Drampyan, S. Pustelny, and W. Gawlik, Phys. Rev. A 80, 033815 (2009)
2009
-
[55]
P. D. Schwindt, L. Hollberg, and J. Kitching, Rev. Sci. Instrum. 76, 1 (2005)
2005
-
[56]
J. M. Higbie, E. Corsini, and D. Budker, Rev. Sci. In- strum. 77, 10.1063/1.2370597 (2006)
2006 doi
-
[57]
Phys. Lett. A 48, 283 (1974)
1974
-
[58]
Phys.B 20, 5939 (1987)
J. Phys.B 20, 5939 (1987)
1987
-
[59]
M. J. Owens and R. J. Forsyth, Living Rev. Sol. Phys. 10, 5 (2013)
2013
-
[60]
J. E. P. Connerney, A. Adriani, F. Allegrini, F. Bagenal, S. J. Bolton, B. Bonfond, S. W. H. Cowley, J.-C. Ger- ard, G. R. Gladstone, D. Grodent, G. Hospodarsky, J. L. Jorgensen, W. S. Kurth, S. M. Levin, B. Mauk, D. J. McComas, A. Mura, C. Paranicas, E. J. Smith, R. M. Thorne...
2017
-
[61]
M. H. Acu˜ na, J. E. P. Connerney, N. F., null, R. P. Lin, D. Mitchell, C. W. Carlson, J. McFadden, K. A. Ander- son, H. R` eme, C. Mazelle, D. Vignes, P. Wasilewski, and P. Cloutier, Science 284, 790 (1999)
1999
-
[62]
P. A. Koss, A. R. Durmaz, A. Blug, G. Laskin, O. S. Pawar, K. Thiemann, A. Bertz, T. Straub, and C. El- saesser, Appl. Sci. 12, 1329 (2022). 9
2022
-
[63]
Pustelny, A
S. Pustelny, A. Wojciechowski, M. Kotyrba, K. Sycz, J. Zachorowski, W. Gawlik, A. Cingoz, N. Leefer, J. Hig- bie, E. Corsini, M. Ledbetter, S. Rochester, A. Sushkov, and D. Budker, in Proc. SPIE , Vol. 6604 (2007)
2007
-
[64]
W lodarczyk, Podzespo ly elektroniczne i optoelektron- iczne w magnetometrii atomowej (eng
P. W lodarczyk, Podzespo ly elektroniczne i optoelektron- iczne w magnetometrii atomowej (eng. Electronic and op- toelectronic components in atomic magnetometry), Ph.D. thesis, University of Science and Technology (2016)
2016
-
[65]
Sohler, H
W. Sohler, H. Hu, R. Ricken, V. Quiring, C. Vannahme, H. Herrmann, D. B¨ uchter, S. Reza, W. Grundk¨ otter, S. Orlov, H. Suche, R. Nouroozi, and Y. Min, Opt. Pho- ton. News 19, 24 (2008)
2008
-
[66]
A. Boes, B. Corcoran, L. Chang, J. Bowers, and A. Mitchell, Laser Photon. Rev. 12, 1700256 (2018)
2018
Reviewed August 10, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.