Pith. sign in

REVIEW 1 cited by

Design, construction and commissioning of a high-flow radon removal system for XENONnT

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2205.11492 v1 pith:S7BQJBMC submitted 2022-05-23 physics.ins-det

classification physics.ins-det
keywords radondistillationxenonxenonntdesignliquidprocesssystem
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT liquid xenon inventory of 8.4 tonnes at process flows up to 71 kg/h (200 slpm) is required to achieve a radon reduction by a factor two for radon sources inside the detector. To reach such high flows, the distillation column's design features liquid xenon inlet and outlets along with novel custom-made bath-type heat exchangers with high liquefaction capabilities. The distillation process was designed using a modification of the McCabe-Thiele approach without a bottom product extraction. The thermodynamic concept is based on a Clausius-Rankine cooling cycle with phase-changing medium, in this case the xenon itself. To drastically reduce the external cooling power requirements, an energy efficient heat pump concept was developed applying a custom-made four cylinder magnetically-coupled piston pump as compressor. The distillation system was operated at thermodynamically stable conditions at a process flow of (91$\pm$2) kg/h ((258$\pm$6) slpm), 30 % over design. With this flow, a $^{222}$Rn activity concentration <1 $\mu$Bq/kg is expected inside the XENONnT detector given the measured radon source distribution.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

    physics.ins-det 2025-08 conditional novelty 6.0 of 10

    Flow-dependent tagging, built from paired radon-polonium decays, identifies 63% of 214Pb beta-decay backgrounds in LZ's fiducial volume at 9.0% exposure cost.