Pith. sign in

REVIEW 1 cited by

Proportional scintillation in liquid xenon: demonstration in a single-phase liquid-only time projection chamber

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2405.10687 v2 pith:S7RVZUFT submitted 2024-05-17 physics.ins-det

classification physics.ins-det
keywords electronliquidproportionalscintillationsingle-phaseanodedriftlight
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The largest direct dark matter search experiments to date employ dual-phase time projection chambers (TPCs) with liquid noble gas targets. These detect both the primary photons generated by particle interactions in the liquid target, as well as proportional secondary scintillation light created by the ionization electrons in a strong electric field in the gas phase between the liquid-gas interface and the anode. In this work, we describe the detection of charge signals in a small-scale single-phase liquid-xenon-only TPC, that features the well-established TPC geometry with light readout above and below a cylindrical target. In the single-phase TPC, the proportional scintillation light (S2) is generated in liquid xenon in close proximity to 10 {\mu}m diameter anode wires. The detector was characterized and the proportional scintillation process was studied using the 32.1 keV and 9.4 keV signals from 83mKr decays. A charge gain factor g2 of up to (1.9 $\pm$ 0.3) PE/electron was reached at an anode voltage 4.4 kV higher than the gate electrode 5 mm below it, corresponding to (29 $\pm$ 6) photons emitted per ionization electron. The duration of S2 signals is dominated by electron diffusion and approaches the xenon de-excitation timescale for very short electron drift times. The electron drift velocity and the longitudinal diffusion constant were measured at a drift field of 470 V/cm. The results agree with the literature and demonstrate that a single-phase TPC can be operated successfully.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Doberman: a modular and distributed slow control system for small- to medium-scale experiments

    physics.ins-det 2026-02 unverdicted novelty 6.0 of 10

    Doberman is a modular, open-source slow control system that has been deployed in experiments with up to about 300 sensors and which, in synthetic tests, handles 1000 Hz readout and 100 Hz control commands.

Pith tools