pith. sign in

arxiv: 1603.06990 · v1 · pith:SRU25U3Vnew · submitted 2016-03-22 · ⚛️ physics.ins-det

Cavity design for high-frequency axion dark matter detectors

classification ⚛️ physics.ins-det
keywords axioncavitiescavitydesignsdetectorssearchesaboveapproximately
0
0 comments X
read the original abstract

In an effort to extend the usefulness of microwave cavity detectors to higher axion masses, above ~8 $\mu$eV (~2 GHz), a numerical trade study of cavities was conducted to investigate the merit of using variable periodic post arrays and regulating vane designs for higher-frequency searches. The results show that both designs could be used to develop resonant cavities for high-mass axion searches. Multiple configurations of both methods obtained the scanning sensitivity equivalent to approximately 4 coherently coupled cavities with a single tuning rod.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. A Near-Cutoff Waveguide Haloscope for sub-meV Dark Matter

    hep-ph 2026-05 unverdicted novelty 7.0

    A novel waveguide haloscope concept using near-cutoff slow-wave response for sub-meV bosonic dark matter, projecting dark photon sensitivity of ε≈2.1×10^{-15} at 0.1 meV.