Pith. sign in

REVIEW 2 cited by

Statistical Distance-Guided Unsupervised Domain Adaptation for Automated Multi-Class Cardiovascular Magnetic Resonance Image Quality Assessment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2409.00375 v1 pith:TZCCKNA5 submitted 2024-08-31 eess.IV

classification eess.IV
keywords modelproposedstatisticaldatadistancedomainimagequality
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

This study proposes an attention-based statistical distance-guided unsupervised domain adaptation model for multi-class cardiovascular magnetic resonance (CMR) image quality assessment. The proposed model consists of a feature extractor, a label predictor and a statistical distance estimator. An annotated dataset as the source set and an unlabeled dataset as the target set with different statistical distributions are considered inputs. The statistical distance estimator approximates the Wasserstein distance between the extracted feature vectors from the source and target data in a mini-batch. The label predictor predicts data labels of source data and uses a combinational loss function for training, which includes cross entropy and centre loss functions plus the estimated value of the distance estimator. Four datasets, including imaging and k-space data, were used to evaluate the proposed model in identifying four common CMR imaging artefacts: respiratory and cardiac motions, Gibbs ringing and Aliasing. The results of the extensive experiments showed that the proposed model, both in image and k-space analysis, has an acceptable performance in covering the domain shift between the source and target sets. The model explainability evaluations and the ablation studies confirmed the proper functioning and effectiveness of all the model's modules. The proposed model outperformed the previous studies regarding performance and the number of examined artefacts. The proposed model can be used for CMR post-imaging quality control or in large-scale cohort studies for image and k-space quality assessment due to the appropriate performance in domain shift coverage without a tedious data-labelling process.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. HierAdaptMR: Cross-Center Cardiac MRI Reconstruction with Hierarchical Feature Adapters

    cs.CV 2025-08 unverdicted novelty 5.0 of 10

    HierAdaptMR uses hierarchical adapters (protocol-level, center-level, universal) on a variational unrolling backbone to improve cross-center cardiac MRI reconstruction, as evaluated on the CMRxRecon2025 dataset.

  2. An All-in-one Approach for Accelerated Cardiac MRI Reconstruction

    eess.IV 2024-11 conditional novelty 4.0 of 10

    A Patch-GAN based stepwise reconstruction model achieves state-of-the-art average SSIM of 0.9907 and 0.9799 on the two CMRxRecon2024 cardiac MRI reconstruction tasks.