Pith. sign in

REVIEW

A high precision calibration of the nonlinear energy response at Daya Bay

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1902.08241 v2 pith:UVVKHM3Z submitted 2019-02-21 physics.ins-det

Daya Bay Collaboration: D. Adey , F. P. An , A. B. Balantekin , H. R. Band , M. Bishai , S. Blyth , D. Cao , G. F. Cao
show 186 more authors
J. Cao J. F. Chang Y. Chang H. S. Chen S. M. Chen Y. Chen Y. X. Chen J. Cheng Z. K. Cheng J. J. Cherwinka M. C. Chu A. Chukanov J. P. Cummings N. Dash F. S. Deng Y. Y. Ding M. V. Diwan T. Dohnal J. Dove M. Dvořák D. A. Dwyer M. Gonchar G. H. Gong H. Gong W. Q. Gu J. Y. Guo L. Guo X. H. Guo Y. H. Guo Z. Guo R. W. Hackenburg S. Hans M. He K. M. Heeger Y. K. Heng A. Higuera Y. K. Hor Y. B. Hsiung B. Z. Hu J. R. Hu T. Hu Z. J. Hu H. X. Huang X. T. Huang Y. B. Huang P. Huber D. E. Jaffe K. L. Jen S. Jetter X. L. Ji X. P. Ji R. A. Johnson D. Jones L. Kang S. H. Kettell L. W. Koerner S. Kohn M. Kramer T. J. Langford L. Lebanowski J. Lee J. H. C. Lee R. T. Lei R. Leitner J. K. C. Leung C. Li F. Li H. L. Li Q. J. Li S. Li S. C. Li S. J. Li W. D. Li X. N. Li X. Q. Li Y. F. Li Z. B. Li H. Liang C. J. Lin G. L. Lin S. Lin S. K. Lin J. J. Ling J. M. Link L. Littenberg B. R. Littlejohn J. C. Liu J. L. Liu Y. Liu Y. H. Liu C. Lu H. Q. Lu J. S. Lu K. B. Luk X. B. Ma X. Y. Ma Y. Q. Ma C. Marshall D. A. Martinez Caicedo K. T. McDonald R. D. McKeown I. Mitchell L. Mora Lepin J. Napolitano D. Naumov E. Naumova J. P. Ochoa-Ricoux A. Olshevskiy H.-R. Pan J. Park S. Patton V. Pec J. C. Peng L. Pinsky C. S. J. Pun F. Z. Qi M. Qi X. Qian N. Raper J. Ren R. Rosero B. Roskovec X. C. Ruan H. Steiner J. L. Sun K. Treskov W.-H. Tse C. E. Tull B. Viren V. Vorobel C. H. Wang J. Wang M. Wang N. Y. Wang R. G. Wang W. Wang X. Wang Y. Wang Y. F. Wang Z. Wang Z. M. Wang H. Y. Wei L. H. Wei L. J. Wen K. Whisnant C. G. White H. L. H. Wong S. C. F. Wong E. Worcester Q. Wu W. J. Wu D. M. Xia Z. Z. Xing J. L. Xu T. Xue C. G. Yang L. Yang M. S. Yang Y. Z. Yang M. Ye M. Yeh B. L. Young H. Z. Yu Z. Y. Yu B. B. Yue S. Zeng L. Zhan C. Zhang C. C. Zhang F. Y. Zhang H. H. Zhang J. W. Zhang Q. M. Zhang R. Zhang X. F. Zhang X. T. Zhang Y. M. Zhang Y. X. Zhang Y. Y. Zhang Z. J. Zhang Z. P. Zhang Z. Y. Zhang J. Zhao L. Zhou H. L. Zhuang J. H. Zou
This is my paper
classification physics.ins-det
keywords nonlinearitycalibrationenergyresponsedayaelectronicshighprecision
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment's antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by $\gamma$ calibration points from deployed and naturally occurring radioactive sources, the $\beta$ spectrum from $^{12}$B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

Discussion (0). Sign in to comment.

Pith tools