REVIEW 1 cited by
Reliable detection and characterization of low-frequency polarized sources in the LOFAR M51 field
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
The new generation of broad-band radio continuum surveys will provide large data sets with polarization information. New algorithms need to be developed to extract reliable catalogs of linearly polarized sources that can be used to characterize those sources and produce a dense rotation measure (RM) grid to probe magneto-ionized structures along the line of sight via Faraday rotation. The aim of the paper is to develop a computationally efficient and rigorously defined source-finding algorithm for linearly polarized sources. We used a calibrated data set from the LOw Frequency ARray (LOFAR) at 150 MHz centered on the nearby galaxy M51 to search for polarized background sources. With a new imaging software, we re-imaged the field at a resolution of 18''x15'' and cataloged a total of about 3000 continuum sources within 2.5 degrees of the center of M51. We made small Stokes Q and U images centered on each source brighter than 100 mJy in total intensity (201 sources) and used RM synthesis to create corresponding Faraday cubes that were analyzed individually. For each source, the noise distribution function was determined from a subset of measurements at high Faraday depths where no polarization is expected; the peaks in polarized intensity in the Faraday spectrum were identified and the p-value of each source was calculated. Finally, the false discovery rate method was applied to the list of p-values to produce a list of polarized sources and quantify the reliability of the detections. We also analyzed sources fainter than 100 mJy but that were reported as polarized in the literature at at least another radio frequency. Of the 201 sources that were searched for polarization, 6 polarized sources were detected confidently (with a false discovery rate of 5 percent). This corresponds to a number density of 1 polarized source per 3.3 square degrees, or 0.3 source/square degree. [Abridged]
Forward citations
Cited by 1 Pith paper
-
Polarisation and Faraday rotation measure imaging at metre wavelengths with sub-arcsecond resolution: a foundational calibration strategy
A calibration strategy using full-Jones corrections with an in-field unpolarised calibrator and visibility-based multi-epoch alignment enables sub-arcsecond polarimetric imaging with LOFAR at metre wavelengths.
Discussion (0). Sign in to comment.