Pith. sign in

REVIEW

Generalized auto-balanced Ramsey spectroscopy of clock transitions

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1712.03365 v2 pith:WLJPQ54R submitted 2017-12-09 physics.atom-ph physics.app-ph

classification physics.atom-phphysics.app-ph
keywords ramseyspectroscopyclockloopmeasurementsappliedatomiccompensation
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

When performing precision measurements, the quantity being measured is often perturbed by the measurement process itself. This includes precision frequency measurements for atomic clock applications carried out with Ramsey spectroscopy. With the aim of eliminating probe-induced perturbations, a method of generalized auto-balanced Ramsey spectroscopy (GABRS) is presented and rigorously substantiated. Here, the usual local oscillator frequency control loop is augmented with a second control loop derived from secondary Ramsey sequences interspersed with the primary sequences and with a different Ramsey period. This second loop feeds back to a secondary clock variable and ultimately compensates for the perturbation of the clock frequency caused by the measurements in the first loop. We show that such a two-loop scheme can lead to perfect compensation of measurement-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors that are typical of other hyper-Ramsey schemes. Several variants of GABRS are explored based on different secondary variables including added relative phase shifts between Ramsey pulses, external frequency-step compensation, and variable second-pulse duration. We demonstrate that a universal anti-symmetric error signal, and hence perfect compensation at finite modulation amplitude, is generated only if an additional frequency-step applied during both Ramsey pulses is used as the concomitant variable parameter. This universal technique can be applied to the fields of atomic clocks, high-resolution molecular spectroscopy, magnetically induced and two-photon probing schemes, Ramsey-type mass spectrometry, and to the field of precision measurements. Some variants of GABRS can also be applied for rf atomic clocks using CPT-based Ramsey spectroscopy of the two-photon dark resonance.

Discussion (0). Sign in to comment.

Pith tools