Carbon-Aware Computing for Datacenters
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Signed reviews
abstract
The amount of CO$_2$ emitted per kilowatt-hour on an electricity grid varies by time of day and substantially varies by location due to the types of generation. Networked collections of warehouse scale computers, sometimes called Hyperscale Computing, emit more carbon than needed if operated without regard to these variations in carbon intensity. This paper introduces Google's system for Carbon-Intelligent Compute Management, which actively minimizes electricity-based carbon footprint and power infrastructure costs by delaying temporally flexible workloads. The core component of the system is a suite of analytical pipelines used to gather the next day's carbon intensity forecasts, train day-ahead demand prediction models, and use risk-aware optimization to generate the next day's carbon-aware Virtual Capacity Curves (VCCs) for all datacenter clusters across Google's fleet. VCCs impose hourly limits on resources available to temporally flexible workloads while preserving overall daily capacity, enabling all such workloads to complete within a day. Data from operation shows that VCCs effectively limit hourly capacity when the grid's energy supply mix is carbon intensive and delay the execution of temporally flexible workloads to "greener" times.
Forward citations
Cited by 3 Pith papers
-
CWind: A Cross-site Router for Large Language Model Inference Serving at Renewable Energy Farms
XWind is a reactive cross-site router for LLM inference at wind farms that cuts P99 latency by up to 52% versus strong baselines in a 64-GPU emulation of three sites.
-
Achieving Dispatchability in Data Centers: Carbon and Cost-Aware Sizing of Energy Storage and Local Photovoltaic Generation
Data centers can cut carbon by pairing optimally sized PV and storage, but the gains vary from 50% in Bavaria to negative in Aargau, so location-aware sizing is essential.
-
Emission-Forecasting-Based Spatial-Temporal Carbon Response: A Multi-Agent Attention-Enhanced Deep Learning Framework
A hierarchical ANN-CNN-GRU-dual-stage-attention forecaster plus LLM agents predicts day-ahead nodal carbon intensity and feeds a spatial-temporal battery/data-center dispatch model, claiming >30% simulated emission cu...